Submittal Data for FXU48HP230V1R32AH / FXU60HP230V1R32AO
48000 BTU/H Unitary Heat Pump Split System
This section provides fields for project-specific information.
Job Name: [Field for Job Name]
Purchaser: [Field for Purchaser]
Submitted to: [Field for Submitted to]
Unit Designation: [Field for Unit Designation]
Location: [Field for Location]
Engineer: [Field for Engineer]
For: [Field for For]
Schedule No.: [Field for Schedule No.]
Date: [Field for Date]
Attribute | Outdoor Model | Indoor Model |
---|---|---|
Outdoor Model | FXU60HP230V1R32A0 | |
Indoor Model | FXU48HP230V1R32AH |
Attribute | Unit | Values | |||||
---|---|---|---|---|---|---|---|
FXU60HP230V1R32A0 (Min - Max) | FXU48HP230V1R32AH (Rated @95°F) | FXU60HP230V1R32A0 (Min - Max) | FXU48HP230V1R32AH (Rated @47°F) | FXU60HP230V1R32A0 (Rated @17°F) | FXU48HP230V1R32AH (Rated @5°F) | ||
Cooling Capacity | Btu/h | 34,000 - 50,000 | 48,000 | 34,000 - 52,000 | 48,000 | 39,500 | 48,000 |
SEER2 | 19.0 | ||||||
EER2 | 12.0 | ||||||
HSPF2 | 10.0 | ||||||
COP @5°F | 2.0 | ||||||
COP @47°F | 3.4 | ||||||
Cooling Temperature Range | °F | 5 - 129 | |||||
Heating Temperature Range | °F | -22 - 75 | |||||
Refrigerant Type | R32 |
Attribute | Value | Unit |
---|---|---|
Power Supply | 208-230V / 1Ph / 60 Hz | VAC |
Sound Pressure Level | 53 | dB(A) |
Control Voltage | 24 | VAC |
MOCP | 15 | A |
MCA | 7.1 | A |
Electric Heater (Optional) | 6, 9, 12 | kW |
Air Flow | 1200 | CFM |
External Static Pressure (Up to) | 1.0 | In W.c. |
Dehumidification | 8.49 | pt/hr |
Drain Piping | Φ1×0.05 | in |
External Dimensions (W x D x H) | 24-13/16 x 21-1/4 x 52 | in |
Package Dimension (L x W x H) | 27-1/4 x 26 x 54-3/16 | in |
Net Weight | 199.5 | lbs |
Gross Weight | 218.0 | lbs |
Attribute | Value | Unit |
---|---|---|
Power Supply | 208-230V / 1Ph / 60 Hz | VAC |
Sound Pressure Level | 63 | dB(A) |
Control Voltage | 24 | VAC |
Rated Current Cooling | 30 | A |
Rated Current Heating | 32 | A |
MOCP | 45 | A |
MCA | 39.9 | A |
Compressor Type | GREE G20 / Double Cylinder / 2-Stage Inverter | |
External Dimensions (W x H x D) | 35-7/16 x 49-5/8 x 13-3/8 | in |
Package Dimension (W x H x D) | 40-11/16 x 55-3/16 x 17-3/8 | in |
Net Weight | 241.4 | lbs |
Gross Weight | 263.5 | lbs |
Refrigerant Charge - R32 | 162.3 | oz |
Additional Charge | 0.215 | oz/ft |
Attribute | Value | Unit |
---|---|---|
Line Set Size (Liquid - Gas) - Flared Connections | 3/8 - 3/4 | in |
Pre-Charge Length | 31 | ft |
Pipe Length (Min - Max) | 10 - 98 | ft |
Max. Pipe Elevation | 49 | ft |
Feature | Availability |
---|---|
Ultra Low Frequency Torque Control | Yes |
Power Factor Correction | Yes |
Electronic Expansion Valve (EEV) | Yes |
Basepan With Electric Heater | Yes |
Compressor With Electric Heater | Yes |
Fin Coating (Outdoor - Golden & Indoor - Blue) | Acrylic Resin |
Intelligent Defrosting | Yes |
Intelligent Preheating | Yes |
Low Voltage Startup | Yes |
Memory/Power Failure Recovery | Yes |
Self Diagnosis | Yes |
Low Ambient Cooling | Yes |
24VAC Thermostat Compatible | Yes |
Indoor Fan Type | Centrifugal |
Multi Fan Speeds | 5 Speeds |
Auxiliary Electrical Heater | Optional |
A2L Leak Detection Sensor (Indoor) | Factory Installed |
The Fan Performance chart illustrates the relationship between Airflow (CFM) and Static Pressure (Inches W.C.) for various fan speeds.
Dimension Label | Value | Unit |
---|---|---|
A | 11-5/8 | inch |
B | 20 | inch |
H | 52 | inch |
W | 24-13/16 | inch |
D | 21-1/4 | inch |
Dimension Label | Value | Unit |
---|---|---|
A | 35-7/16 | inch |
B | 16-1/4 | inch |
C | 49-5/8 | inch |
D | 22-7/16 | inch |
E | 14-7/8 | inch |
G | 13-3/8 | inch |
Model | Heat Kit Model | Part Number | Supply Type | Electric Heat (kW) | Min. Circuit Ampacity (A) | Max Fuse or Breaker (A) |
---|---|---|---|---|---|---|
FXU48HP230V1R32AH | FLEXA2LHTR06 | 320004060223 | One Mains Supply | 3.74 | 4.6 (208V) / 31 (230V) | 33 (208V) / 35 (230V) |
FLEXA2LHTR09 | 320004060224 | Two Mains Supply | 6.03 (208V) / 7.36 (230V) | 13.8 (208V) / 36.9 (230V) | 15 (208V) / 40 (230V) | |
FLEXA2LHTR12 | 320004060225 | Two Mains Supply | 7.49 (208V) / 9.2 (230V) | 27.5 (208V) / 36.9 (230V) | 30 (208V) / 40 (230V) |
FRONT: Greater than 24 inches (24").
A - E | Hb H Hd | a (in) | b (in) | c (in) | d (in) | e (in) |
---|---|---|---|---|---|---|
B | ≥ 4 | - | - | - | - | - |
A, B, C | > 12 | ≥ 4 | ≥ 4 | - | - | - |
B, E | ≥ 4 | - | - | - | - | ≥ 40 |
A, B, C, E | > 12 | ≥ 6 | ≥ 6 | - | - | ≥ 40 |
D | - | - | - | - | - | ≥ 40 |
D, E | - | - | - | - | - | ≥ 40 |
B, D | Hb < Hd | ≥ 4 | - | - | - | ≥ 40 |
Hb ≥ Hd | ≥ 4 | - | - | - | ≥ 40 | |
C | Hb ≤ 1/2H | - | ≥ 10 | - | ≥ 80 | ≥ 40 |
1/2H < Hb ≤ H | - | ≥ 10 | - | ≥ 80 | ≥ 40 | |
Hb > H | - | Prohibited | - | - | - | |
B, D, E | Hb ≤ 1/2H | - | ≥ 4 | - | ≥ 80 | ≥ 40 |
1/2H < Hb ≤ H | - | ≥ 8 | - | ≥ 80 | ≥ 40 | |
Hb > H | - | Prohibited | - | - | - |
A - E | Hb H Hd | a (in) | b (in) | c (in) | d (in) | e (in) |
---|---|---|---|---|---|---|
A, B, C | > 12 | ≥ 12 | ≥ 12 | - | - | ≥ 40 |
A, B, C, E | > 12 | ≥ 12 | ≥ 12 | - | - | ≥ 40 |
D | - | - | - | - | - | ≥ 80 |
D, E | - | - | - | - | - | ≥ 80 |
B, D | Hb < Hd | - | ≥ 12 | - | ≥ 80 | - |
Hb > H | - | ≥ 12 | - | ≥ 80 | - | |
B, D, E | Hb ≤ 1/2H | - | ≥ 10 | - | ≥ 80 | ≥ 40 |
1/2H < Hb ≤ H | - | ≥ 12 | - | ≥ 100 | ≥ 40 | |
Hb > H | - | Prohibited | - | - | - |
Hb H Hd | b (in) | Clearance (in) |
---|---|---|
Hb ≤ 1/2H | ≤ 10 | ≥ 80 |
1/2H < Hb ≤ H | ≤ 12 | ≥ 100 |
Hb > H | Prohibited | - |
![]() |
GREE FLEXX ULTRA R32 A-Coil Unitary Heat Pump System Specifications Submittal data and technical specifications for the GREE FLEXX ULTRA R32 60000 BTU/H A-Coil Unitary Heat Pump Split System (FXA60C32AH/FXU60HP230V1R32AO), detailing features, performance, dimensions, and installation clearances. |
![]() |
GREE Flexx Ultra R32 FXA24C32AH / FXU36HP230V1R32AO Submittal Data - 24000 BTU/H Heat Pump Detailed submittal data sheet for the GREE Flexx Ultra R32 series FXA24C32AH indoor unit and FXU36HP230V1R32AO outdoor unit. Includes specifications, features, dimensions, and installation clearances for this 24000 BTU/H unitary heat pump split system. |
![]() |
GREE FLEXX ULTRA R32 24000 BTU/H Unitary Heat Pump Split System Submittal Data and Specifications Detailed submittal data, specifications, features, fan performance, dimensions, accessory heater information, and installation clearances for the GREE FLEXX ULTRA R32 24000 BTU/H Unitary Heat Pump Split System, models FXU24HP230V1R32AH and FXU36HP230V1R32AO. |
![]() |
GREE FLEXX ULTRA R32 A-Coil Unitary Heat Pump Submittal Data and Specifications Detailed submittal data, specifications, dimensions, and installation clearances for the GREE FLEXX ULTRA R32 A-Coil Unitary Heat Pump Split System (FXA48C32AH / FXU60HP230V1R32A0), featuring 48000 BTU/H capacity. |
![]() |
GREE FLEXX ULTRA R32 Heat Pump Submittal Data & Specifications Detailed submittal data, specifications, dimensions, and clearance requirements for the GREE FLEXX ULTRA R32 36000 BTU/H A-Coil Unitary Heat Pump Split System (FXA36C32AH / FXU36HP230V1R32AO). |
![]() |
GREE FLEXX ULTRA R32 Central Air System | High Efficiency Climate Control Explore the GREE FLEXX ULTRA R32, a versatile central air system offering exceptional flexibility across all climates. Featuring high SEER2, EER2, and HSPF2 ratings, this system provides efficient cooling and heating for new construction and replacement projects. |
![]() |
GREE FLEXX ULTRA R32 Air Handler Owner's Manual & Installation Guide Comprehensive owner's manual and installation guide for GREE FLEXX ULTRA R32 Air Handler models FXU24HP230V1R32AH, FXU36HP230V1R32AH, FXU48HP230V1R32AH, and FXU60HP230V1R32AH. Covers safety, operation, installation, maintenance, and troubleshooting. |
![]() |
GREE VIR09HP230V1R32AH/AO 9000 BTU/H R32 Wall Mounted Heat Pump System - Submittal Data & Specifications Detailed submittal data, specifications, features, dimensions, and clearances for the GREE VIR09HP230V1R32AH/AO 9000 BTU/H R32 Wall Mounted Heat Pump System. Includes technical performance data and installation requirements. |