[Rheem Logo]

Rheem Endeavor™ Line Classic® Series Gas Furnaces

Model: R801T

Key Specifications: 80% A.F.U.E.†, Single Stage, Constant Torque, Input Rates: 50-125 kBTU [14.6-36.6 kW], Configuration Options: Upflow/Horizontal

† A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Certifications: ISO 9001:2015, cULus Listed, AHRI Certified.

Learn more at ahridirectory.org.

Features & Benefits

Model Number Identification

The model number for Rheem Endeavor™ Line Classic® Series Gas Furnaces follows a specific structure:

R 80 1 T 050 3 A 14 UH S N A S

ComponentDescription
RBrand (Rheem)
80Furnace Efficiency (80% AFUE)
1Stages of Heating (Single-Stage)
TMotor Type (Constant Torque)
050Heating Input (50K BTUH [14.7 kW])
3AC Max. Capacity (3-ton drive)
AMajor Series (1st Design)
14Width (14" Width)
UHPosition (Upflow/Horizontal)
SControls (Standard)
NNOx (Non-Comm. / Low NOx)
AMinor Series (1st Series)
SOption Code (Standard Grade)

Available Models

Standard Equipment

WARNING: THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES.

Physical Data and Specifications

Upflow Models

MODEL NUMBERS R801T Constant Tq-UH SeriesInput-BTU/Hr [kW]Heating Capacity BTU/Hr [kW]Heat Ext. Static Pressure [kPa]Blower (D x W) [mm]Motor H.P. [W] TypeMin. Circuit AmpacityMin. Overload Protection DeviceMax. Overload Protection DeviceHeating SpeedCooling SpeedCooling CFM @ Rating Point [L/s]Max. E.S.P. (In. W.C.) [kPa]Temperature Rise Range °F [°C]Max. Outlet Air Temp. °F [°C]Approx. Shipping Weight (Lbs.) [kg]AFUE
R801T0503A14UH*NAS50,000 [15]40,000 [12].18 [.05]11 x 6 [279 x 152]1/2 [373]
5 Spd Constant Torque
81515MedHigh1305 [616]0.9 [.22]25-55 [13.9-30.6]155 [68.3]110 [50]80.00%
R801T0754A17UH*NAS75,000 [22]60,000 [18].20 [.05]11 x 7 [279 x 178]1/2 [373]
5 Spd Constant Torque
81515MedHigh1402 [662]0.9 [.22]25-55 [13.9-30.6]155 [68.3]125 [57]80.00%
R801T0754A21UH*NAS75,000 [22]60,000 [18].20 [.05]11 x 7 [279 x 178]3/4 [560]
5 Spd Constant Torque
91515Med-HighHigh1608 [759]0.9 [.22]25-55 [13.9-30.6]160 [71.1]140 [64]80.00%
R801T1005A21UH*NAS100,000 [29]80,000 [23].28 [.07]11 x 10 [279 x 254]3/4 [560]
5 Spd Constant Torque
101515MedHigh1840 [868]0.9 [.22]40-70 [22-39]180 [82.2]140 [64]80.00%
R801T1255A24UH*NAS125,000 [37]100,000 [29].28 [.07]11 x 10 [279 x 254]3/4 [560]
5 Spd Constant Torque
111515Med-HighHigh1934 [913]0.9 [.22]35-65 [19.4-36.1]165 [73.8]150 [68]80.00%

Horizontal Models

MODEL NUMBERS R801T Constant Tq-UH SeriesInput-BTU/Hr [kW]Heating Capacity BTU/Hr [kW]Heat Ext. Static Pressure [kPa]Blower (D x W) [mm]Motor H.P. [W] TypeMin. Circuit AmpacityMin. Overload Protection DeviceMax. Overload Protection DeviceHeating SpeedCooling SpeedCooling CFM @ Rating Point [L/s]Max. E.S.P. (In. W.C.) [kPa]Temperature Rise Range °F [°C]Max. Outlet Air Temp. °F [°C]Approx. Shipping Weight (Lbs.) [kg]AFUE
R801T0503A14UH*NAS50,000 [15]40,000 [12].18 [.05]11 x 6 [279 x 152]1/2 [373]
5 Spd Constant Torque
81515MedHigh1305 [616]0.9 [.22]25-55 [13.9-30.6]155 [68.3]110 [50]80.00%
R801T0754A17UH*NAS75,000 [22]60,000 [18].20 [.05]11 x 7 [279 x 178]1/2 [373]
5 Spd Constant Torque
81515MedHigh1402 [662]0.9 [.22]25-55 [13.9-30.6]155 [68.3]125 [57]80.00%
R801T0754A21UH*NAS75,000 [22]60,000 [18].20 [.05]11 x 7 [279 x 178]3/4 [560]
5 Spd Constant Torque
91515Med-HighHigh1608 [759]0.9 [.22]25-55 [13.9-30.6]160 [71.1]140 [64]80.00%
R801T1005A21UH*NAS100,000 [29]80,000 [23].28 [.07]11 x 10 [279 x 254]3/4 [560]
5 Spd Constant Torque
101515MedHigh1840 [868]0.9 [.22]40-70 [22-39]180 [82.2]140 [64]80.00%
R801T1255A24UH*NAS125,000 [37]100,000 [29].28 [.07]11 x 10 [279 x 254]3/4 [560]
5 Spd Constant Torque
111515Med-HighHigh1934 [913]0.9 [.22]35-65 [19.4-36.1]165 [73.8]150 [68]80.00%

NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2" [12 mm] N.P.T.

This furnace does not meet air district requirements of 14 ng/J NOx emissions limit. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.

This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits. Operating in natural gas mode is in violation of these Rules.

[ ] Designates Metric Conversions

Dimensional Data

Upflow Application

Diagram illustrating the Upflow Application of the Rheem Endeavor™ gas furnace. It shows the unit from the BOTTOM view, indicating the RETURN AIR intake. The TOP view shows the SUPPLY AIR outlet. Side views (LEFT SIDE, RIGHT SIDE) and FRONT view detail connection points for GAS CONNECTION, LINE VOLTAGE ELECTRICAL CONNECTION, and LOW VOLTAGE ELECTRICAL CONNECTION. Key dimensions are labeled A, B, C, D, E, and F, with corresponding metric conversions in brackets. Minimum clearance requirements are also indicated.

MODEL R801T-ABCDEFMINIMUM CLEARANCE (IN.) [mm]SHIP WGTS. (LBS.) [kg]
LEFT SIDERIGHT SIDEBACKTOPFRONTVENT
05014 [356]1227/32 [326]105/8 [270]111/2 [292]17/8 [48]04 [102]01 [25]3 [76]6 [152]110 [50]
075417171/2 [445]1611/32 [415]123/8 [314]151/2 [381]21/2 [64]03 [76]01 [25]3 [76]6 [152]125 [57]
075421/100211/2 [533]1927/32 [504]141/8 [359]181/2 [470]21/2 [64]0001 [25]3 [76]6 [152]140 [64]
125241/2 [622]2311/32 [593]157/8 [403]221/2 [559]21/2 [64]0001 [25]3 [76]6 [152]150 [68]

NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. May be 0" [0 mm] with type B vent. May be 1" [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.

[ ] Designates Metric Conversions

Horizontal Application

Diagram illustrating the Horizontal Application of the Rheem Endeavor™ gas furnace. It shows the unit from the SUPPLY AIR side and RETURN AIR side. The FRONT view details connection points for GAS CONNECTION, LINE VOLTAGE ELECTRICAL CONNECTION, and LOW VOLTAGE ELECTRICAL CONNECTION. Key dimensions are labeled A, B, C, D, E, and F, with corresponding metric conversions in brackets. Minimum clearance requirements are also indicated. A warning is present stating the furnace is not approved for installation on its back with access doors facing upwards.

MODEL R801TABCDEFMINIMUM CLEARANCE (IN.) [mm]SHIP WGTS. (LBS.) [kg]
SUPPLY AIR SIDERETURN AIR SIDEBACKTOPFRONTVENT
05014 [356]1227/32 [326]105/8 [270]111/2 [292]17/8 [48]4 [102]4 [102]01 [25]3 [76]6 [152]110 [50]
075417171/2 [445]1611/32 [415]123/8 [314]151/2 [381]21/2 [64]3 [76]3 [76]01 [25]3 [76]6 [152]125 [57]
075421/100211/2 [533]1927/32 [504]141/8 [359]181/2 [470]21/2 [64]0001 [25]3 [76]6 [152]140 [64]
125241/2 [622]2311/32 [593]157/8 [403]221/2 [559]21/2 [64]0001 [25]3 [76]6 [152]150 [68]

NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. May be 0" [0 mm] with type B vent. May be 1" [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.

[ ] Designates Metric Conversions

Blower Performance Data

Air Flow Performance - 80% Single Stage Upflow/ Horizontal Constant Torque

INPUT [BTU]
CABINET
WIDTH [IN]
AIRFLOW CONTROL
SETTINGS
SPEED TAP/
WIRE
COLORS
CFM AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN
0.10.20.30.40.50.60.70.80.91.0
50K
14"
Factory Setting FanLow/Red915777674598541498460419370304
CoolMedium Low/ Yellow963894834781733689646602555504
Heat or Heat/CoolMedium/ Purple997976947911870825779732687646
CoolMedium High/ Blue112311301121110110711036997957920888
75K
17"
CoolHigh/Black1246124412321211118511541121108710541024
Factory Setting CoolingLow/Red967916865814763712661610558505
Factory Setting FanMedium Low/ Yellow1206114710871027966905843783722662
CoolMedium/ Purple1301126012141164111110581005955910870
Heat or Heat/CoolMedium High/ Blue141313691324127712161174113210881043998
75K
21"
CoolHigh/Black15901556815301486143713871342130312761265
Factory Setting CoolingLow/Red12161174113210881043998952905858811
Factory Setting FanMedium Low/ Yellow13141271122911881147110510631019974926
CoolMedium/ Purple1400135613151276123912001161112010761027
Heat or Heat/CoolMedium High/ Blue1605159815481499144914001365133313031285
100K
21"
CoolHigh/Black1796174616981652160615611515146914221374
Factory Setting CoolingLow/Red1233116210911018944869793716637565
Factory Setting FanMedium Low/ Yellow134812891229116811061044982920859799
CoolMedium/ Purple146514091353129612391183112810731019965
Heat or Heat/CoolMedium High/ Blue1658160715571507145714071358130812601212
125K
24"
CoolHigh/Black1758171016631616156915221475142813801334
Factory Setting CoolingLow/Red121611381061986914844778715657601
Factory Setting FanMedium Low/ Yellow1649159815481499144914001351130212521201
CoolMedium/ Purple1796174616981652160615611515146914221374
Heat or Heat/CoolMedium High/ Blue1878182817811735169116471604156015161470
CoolHigh/Black1943189318461801175717141673163115891547

Accessories

Filter Rack Sizes:

MODELRXGF-CB (UPFLOW/ HORIZONTAL)RXGF-CD (UPFLOW) SIDE RETURN
R801TA050121/4 x 25 [311 x 635]153/4 x 25 [400 x 635]
R801TA075417153/4 x 25 [400 x 635]153/4 x 25 [400 x 635]
R801TA075421/ R801TA100191/4 x 25 [489 x 635]153/4 x 25 [400 x 635]
R801TA125223/4 x 25 [578 x 635]153/4 x 25 [400 x 635]

4" FLUE ADAPTER: RXGW-C01

Indoor Coil Casings:

WARNING: A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.

For High Altitudes

OPTION CODE FOR HIGH ALTITUDE: U.S. None required for high altitudes.

HIGH ALTITUDE CONVERSION KITS: U.S. None required for high altitudes.

80+ HIGH ALTITUDE INSTRUCTIONS: CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.

[ ] Designates Metric Conversions

General Terms of Limited Warranty

Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

ItemWarranty Period
Conditional Parts (Registration Required)Ten (10) Years
Heat ExchangerTwenty (20) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

© 2022 Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road • Fort Smith, Arkansas 72908 • www.rheem.com

FORM NO. G11-662 REV. 1

Models: R801T Endeavor Line Classic Series Gas Furnaces, R801T, Endeavor Line Classic Series Gas Furnaces, Gas Furnaces, Furnaces

File Info : application/pdf, 12 Pages, 1.33MB

PDF preview unavailable. Download the PDF instead.

R801T Endeavor Technical Specifications

References

Adobe PDF Library 16.0.7

Related Documents

Preview Rheem Endeavor 80% AFUE Gas Furnaces: Comfort, Efficiency & Reliability
Explore the Rheem Endeavor Line of 80% AFUE gas furnaces, offering dependable comfort, exceptional value, and advanced features like EcoNet® and Bluetooth connectivity for efficient home heating.
Preview Rheem Endeavor 90%+ AFUE Gas Furnace Series: Powerful Performance and Efficiency
Explore the Rheem Endeavor line of 90%+ AFUE gas furnaces, offering powerful performance, exceptional comfort, and significant energy savings. Learn about features like EcoNet compatibility, Bluetooth connectivity, and industry-leading warranties.
Preview Rheem Endeavor R962V Gas Furnace: High Efficiency, Comfort & Smart Control
Discover the Rheem Endeavor R962V gas furnace, featuring 96% AFUE, ENERGY STAR certification, Bluetooth diagnostics, and EcoNet smart thermostat compatibility for enhanced comfort, efficiency, and reliability.
Preview Rheem Endeavor Series R951V****U Gas Furnace: High Comfort, Low Emissions
Discover the Rheem Endeavor Series R951V****U gas furnace, offering high comfort, low emissions, and advanced efficiency with EcoNet® enabled technology. Learn about its features, benefits, and warranty.
Preview Rheem UGDG Series 80% Gas Furnace Parts List
Comprehensive parts list for the Rheem UGDG Series 80% Gas Furnace, detailing model and serial number explanations, and providing part numbers categorized by section (panels, electrical, blower, heat exchanger, gas controls, etc.). Includes diagrams and notes. Current as of December 27, 2017.
Preview Rheem RGEHYB360 Series Commercial Packaged Gas Electric Units - Specifications and Features
Discover the Rheem RGEHYB360 Series Commercial Resolute™ Line Classic® Series Packaged Gas Electric Units. This document details features, specifications, performance data, and installation information for these high-efficiency HVAC systems.
Preview Rheem RP14 Classic Series Heat Pump: Features, Specifications, and Performance