Rheem RP14 Classic Series Heat Pump

14 SEER / 11.5 EER / 8.2 HSPF

Nominal Sizes: 1.5 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities: 17.3 to 60.5 kBTU [5.7 to 17.7 kW]

"Proper sizing and installation of equipment is critical to achieve optimal performance."

Key Features and Benefits

Available Models

Model Number Nominal Tonnage Description
RP1418CJ1NA 1.5 Ton Classic® 1 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1424AJ1NA 2.0 Ton Classic® 2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1430AJ1NA 2.5 Ton Classic® 2 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1436AC1NA 3.0 Ton Classic® 3 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1436AD1NA 3.0 Ton Classic® 3 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1436AJ1NA 3.0 Ton Classic® 3 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1442AJ1NA 3.5 Ton Classic® 3 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1448AC1NA 4.0 Ton Classic® 4 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1448AD1NA 4.0 Ton Classic® 4 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1448AJ1NA 4.0 Ton Classic® 4 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1460AD1NA 5.0 Ton Classic® 5 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1460BC1NA 5.0 Ton Classic® 5 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1460BJ1NA 5.0 Ton Classic® 5 ton 14 SEER Single-Stage Heat Pump-460/3/60

Physical Data

Model No.# Nominal Tonnage Valve Connections Liquid Line O.D. in. Suction Line O.D. in. Refrigerant (R410A) furnished oz. Compressor Type Outdoor Coil Net face area Outer Coil sq. ft. Outdoor Coil Net face area Inner Coil sq. ft. Outdoor Coil Tube diameter in. Outdoor Coil Number of rows Outdoor Coil Fins per inch Outdoor Fan Diameter in. Outdoor Fan Number of blades Outdoor Fan Motor hp Outdoor Fan CFM Outdoor Fan RPM Outdoor Fan watts Shipping weight lbs. Operating weight lbs.
RP1418 1.5 3/8 3/4 123 11.14 -- 3/8 1 20 20 2 1/8 2478 1077 151 159 152
RP1424 2.0 3/8 3/4 89 9.1 -- 3/8 1 20 20 2 1/8 2410 1077 156 152 145
RP1430 2.5 3/8 3/4 106 11.1 -- 3/8 1 20 20 3 1/8 2535 1077 142 208 201
RP1436 3.0 3/8 3/4 111 Scroll 14.8 -- 3/8 1 20 24 3 1/6 3335 825 173 187 187
RP1442 3.5 3/8 7/8 155 14.8 -- 3/8 1 20 24 2 1/5 2933 825 161 208 201
RP1448 4.0 3/8 7/8 143 19.8 -- 3/8 1 20 24 3 1/5 4055 825 228 234 227
RP1460 5.0 3/8 7/8 232 24.2 -- 3/8 1 20 26 3 1/5 4780 850 279 269 262

Electrical Data

Line Voltage Data (Volts-Phase-Hz) Maximum overcurrent protection (amps) Minimum circuit ampacity Compressor Rated load amps Compressor Locked rotor amps Condenser Fan Motor Full load amps Condenser Fan Motor Locked rotor amps
208/230-1-60 20/20 12/12 9/9 48.0 0.75 1.3
208/230-1-60 20 14 10.3 61.6 0.8 1.5
208/230-1-60 30 19 14.1 73 0.8 1.5
208/230-1-60 35 22 16.7 79 0.8 1.5
208/230-1-60 40 24 17.9 112 1 1.8
208/230-1-60 50 29 21.8 117 1.2 2.2
208/230-1-60 50 31 23.7 152.5 1.4 2.8
208/230-3-60 20 14 10.4 73 0.8 1.5
208/230-3-60 30 18 13.5 88 1 1.8
208/230-3-60 30 19 13.7 83.1 1.2 2.2
208/230-3-60 35 22 15.9 110 1.4 2.8
460-3-60 15 8 5.8 38 0.5 1.1
460-3-60 15 9 6 44 0.6 1.3
460-3-60 15 9 6.2 41 0.6 1.5
460-3-60 15 10 7.1 52 0.5 1.4

Note: Refrigerant charge is sufficient for 15 ft. length of refrigerant lines. For longer line set requirements, consult installation instructions.

Optional Accessories

Accessory RP1418 RP1424 RP1430 RP1436 RP1442 RP1448 RP1460
Compressor crankcase heater 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 Factory Standard
Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Low pressure control* Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
High pressure control* Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz) Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Liquid Line Solenoid (24 VAC, 50/60 Hz) Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Liquid Line Solenoid (24 VAC, 50/60 Hz) Bi-flow kit* KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387
Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Bi-flow kit* KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387
Classic Top Cap w/Label Heat Pump Riser 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21
Classic Top Cap w/Label Heat Pump Riser 686020 686020 686020 686020 686020 686020 686020

*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.

Weighted Sound Power Level (dBA)

Unit Size / Voltage, Series Standard Rating (dBA) Octave Band Spectrum (dBA) 250 Hz Octave Band Spectrum (dBA) 500 Hz Octave Band Spectrum (dBA) 1000 Hz Octave Band Spectrum (dBA) 2000 Hz Octave Band Spectrum (dBA) 4000 Hz Octave Band Spectrum (dBA) 8000 Hz
RP1418C / 208/230-1-60 76.4 61.8 66.2 66.8 62.9 58 52
RP1424A / 208/230-1-60 75 59.8 64.8 66.1 62.3 57.7 53
RP1430A / 208/230-1-60 77 60.5 65.4 66.9 63.9 59.9 53.1
RP1436A / 208/230-1-60 74 58 63.5 65.1 61.2 56.1 53.7
RP1442A / 208/230-1-60 76 61 63.9 66.9 69.5 56.7 51.1
RP1448A / 208/230-1-60 77 54.3 64.2 65.5 60.8 57.2 52.9
RP1460B / 208/230-1-60 73.9 55.7 63.4 63.3 61.5 58.6 56.4

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).

Unit Dimensions

MODEL NUMBER OPERATING H (Height) OPERATING L (Length) OPERATING W (Width) SHIPPING H (Height) SHIPPING L (Length) SHIPPING W (Width)
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RP1418CJ 25.16 639 30.13 765 30.13 765 27.90 709 33.25 845 33.00 838
RP1424AJ 25.16 639 30.13 765 30.13 765 27.90 709 33.25 845 33.00 838
RP1430AJ 25.16 639 30.13 765 30.13 765 27.90 709 33.25 845 33.00 838
RP1436AC 27.16 690 34.13 867 34.13 867 30.08 764 37.64 956 37.56 954
RP1442CJ 27.16 690 34.13 867 34.13 867 35.00 889 33.75 857 33.75 857
RP1448AJ 27.16 690 34.13 867 34.13 867 38.35 974 37.64 956 37.56 954
RP1460AD 39.17 995 36.13 918 36.13 918 42.00 1067 39.37 1000 39.64 1007
RP1460BJ 45.17 1147 36.13 918 36.13 918 48.18 1224 39.37 1000 39.64 1007

Installation Clearances

Diagram shows recommended minimum clearances for installation: 24 inches (609.6 mm) for service access on sides and front, 12 inches (304.8 mm) on the other side, and 6 inches (152.4 mm) for wall clearance. Ensure adequate ventilation in enclosed areas to prevent re-circulation of discharge air.

Control Wiring

Illustrates typical thermostat control wiring for a heat pump system with electric heat, showing connections between a heat pump thermostat, an air handler, and the outdoor unit. Includes notes on jumper settings for supplemental heat and defrost control.

Application Guidelines

Refrigerant Line Size Information

Detailed tables provide recommended liquid and vapor line sizes based on unit tonnage, linear line length, and vertical separation between the outdoor and indoor units, including capacity multipliers. Data is provided in both English and Metric units. Consult these tables for proper system design to ensure optimal performance and oil return.

English Units (14 - 15 SEER Single-Stage Heat Pumps)

Unit Size Allowable Liquid Line Size Allowable Vapor Line Size Linear Line Lengths (Feet) Max Vertical Separation / Capacity Multiplier
< 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200
1.5 Ton 1/4" 5/8" 98 98 25 / 1.00 50 / 0.99 62 / 0.98 43 / 0.98 24 / 0.97 5 / 0.97 NR
5/16" 5/8" 78 78 25 / 1.00 50 / 0.99 75 / 0.98 98 / 0.98 93 / 0.97 88 / 0.97 83 / 0.96
3/8" 5/8" 57 57 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.99
2 Ton 1/4" 3/4" 98 78 25 / 1.00 50 / 1.00 62 / 0.99 43 / 0.99 24 / 0.99 5 / 0.99 NR
5/16" 3/4" 78 78 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98
3/8" 3/4" 57 57 25 / 1.00 50 / 1.00 75 / 1.00 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98
2.5 Ton 5/16" 5/8" 128 103 25 / 0.99 50 / 0.98 75 / 0.96 70 / 0.94 59 / 0.93 48 / 0.91 36 / 0.90
3/8" 5/8" 85 68 25 / 0.99 50 / 0.98 75 / 0.96 100 / 0.94 98 / 0.93 94 / 0.91 90 / 0.90
3 Ton 5/16" 3/4" 115 98 25 / 1.00 50 / 0.99 66 / 0.98 49 / 0.98 32 / 0.97 15 / 0.96 NR
3/8" 3/4" 77 65 25 / 1.00 50 / 0.99 75 / 0.98 95 / 0.98 89 / 0.97 84 / 0.96 78 / 0.95
3.5 Ton 3/8" 7/8" 67 93 25 / 0.99 50 / 0.98 75 / 0.97 88 / 0.96 80 / 0.95 72 / 0.94 65 / 0.92
1/2" 7/8" 33 47 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.92
4 Ton 3/8" 3/4" 67 93 25 / 0.99 50 / 0.98 75 / 0.97 88 / 0.96 80 / 0.95 72 / 0.94 65 / 0.92
1/2" 3/4" 33 47 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.92
5 Ton 3/8" 7/8" 67 93 25 / 1.00 50 / 1.00 75 / 0.99 88 / 0.99 80 / 0.99 72 / 0.98 65 / 0.97
1/2" 7/8" 33 47 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.98 100 / 0.97 100 / 0.96

NOTES: 1. Do not exceed 200 ft linear line length. 2. Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3. *3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Metric Units (14 - 15 SEER Single-Stage Heat Pumps)

Unit Size Allowable Liquid Line Size mm [in.] Allowable Vapor Line Size mm [in.] Linear Line Lengths (Meters) Max Vertical Separation / Capacity Multiplier
< 8 8-15 16-23 24-30 31-38 39-46 47-53 54-61
1.5 Ton [5.3 KW] 6.35 [1/4] 15.88 [5/8] 30 15 / 0.99 19 / 0.98 13 / 0.98 7 / 0.97 2 / 0.97 NR NR
7.94 [5/16] 15.88 [5/8] 24 15 / 0.99 23 / 0.98 30 / 0.98 28 / 0.97 27 / 0.97 25 / 0.96 NR
9.53 [3/8] 15.88 [5/8] 17 8 / 1.00 8 / 1.00 8 / 1.00 8 / 1.00 8 / 1.00 8 / 1.00 NR
2 Ton [7.0 KW] 6.35 [1/4] 19.05 [3/4]* 30 8 / 1.00 15 / 0.99 6 / 0.98 NR NR NR NR
7.94 [5/16] 19.05 [3/4]* 24 15 / 1.00 23 / 0.99 27 / 0.98 27 / 0.97 24 / 0.97 21 / 0.96 NR
9.53 [3/8] 19.05 [3/4]* 17 8 / 1.00 15 / 1.00 15 / 0.99 15 / 0.99 15 / 0.99 15 / 0.98 NR
2.5 Ton [8.8 KW] 7.94 [5/16] 15.88 [5/8] 39 8 / 0.99 15 / 0.98 23 / 0.96 21 / 0.94 18 / 0.93 15 / 0.91 11 / 0.90
9.53 [3/8] 15.88 [5/8] 26 8 / 0.99 15 / 0.98 23 / 0.97 19 / 0.96 15 / 0.95 12 / 0.94 9 / 0.93
3 Ton [10.6 KW] 7.94 [5/16] 19.05 [3/4] 39 8 / 1.00 15 / 0.99 23 / 0.98 18 / 0.98 15 / 0.97 12 / 0.96 9 / 0.95
9.53 [3/8] 19.05 [3/4] 26 8 / 1.00 15 / 0.99 23 / 0.98 27 / 0.98 24 / 0.97 22 / 0.96 20 / 0.95
3.5 Ton [12.3 KW] 9.53 [3/8] 22.23 [7/8] 20 8 / 0.99 15 / 0.97 23 / 0.94 18 / 0.92 15 / 0.90 NR NR
12.70 [1/2] 22.23 [7/8] 10 8 / 0.99 15 / 0.97 23 / 0.94 29 / 0.92 27 / 0.90 25 / 0.88 NR
4 Ton [14.1 KW] 9.53 [3/8] 19.05 [3/4] 26 8 / 0.99 15 / 0.97 23 / 0.94 19 / 0.92 14 / 0.90 NR NR
12.70 [1/2] 19.05 [3/4] 13 8 / 0.99 15 / 0.97 23 / 0.94 30 / 0.92 30 / 0.90 30 / 0.88 30 / 0.86
5 Ton [17.6 KW] 9.53 [3/8] 22.23 [7/8] 26 8 / 1.00 15 / 0.99 23 / 0.98 19 / 0.98 14 / 0.97 10 / 0.96 5 / 0.95
12.70 [1/2] 22.23 [7/8] 13 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.97 30 / 0.96 30 / 0.95 30 / 0.94

NOTES: 1. Do not exceed 61 meters linear line length. 2. Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit. 3. *19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data @ AHRI Standard Conditions

Designated Tested Combination (DTC) Outdoor Unit Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] Heating Capacity BTU/H [kW] (47°F) COP (47°F) HSPF Heating Capacity BTU/H [kW] (17°F) Region (17°F) COP (17°F)
RP1418CJ1 RH1T2417STAN 18000 [5.3] 14000 [4.1] 3600 [1.1] 14 11.5 650 [306.8] 15700 [4.60] 3.6 8.2 9100 [2.70] IV 2.4
RP1424AJ1 RH1T2417STAN 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 825 [389.4] 22800 [6.70] 3.6 8.2 12600 [3.70] 2.34
RP1430AJ1 RH1T3617STAN 28800 [8.4] 22200 [6.5] 6600 [1.9] 14 11.5 1050 [495.5] 27400 [8.00] 3.5 8.2 16600 [4.90] 2.34
RP1436AC1 RH1T3617STAN 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.20] 3.66 9 23200 [6.80] 2.54
RP1436AD1 RH1T3617STAN 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.20] 3.66 9 23200 [6.80] 2.54
RP1436AJ1 RH1T3617STAN 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.20] 3.66 9 23200 [6.80] 2.54
RP1442AC1 RH1T4821STAN 42500 [12.5] 32400 [9.5] 10100 [3.0] 14 11.5 1400 [660.7] 39000 [11.40] 3.6 9 24800 [7.30] 2.5
RP1442AD1 RH1T4821STAN 42500 [12.5] 32400 [9.5] 10100 [3.0] 14 11.5 1400 [660.7] 39000 [11.40] 3.6 9 24800 [7.30] 2.5
RP1442AJ1 RH1T4821STAN 42500 [12.5] 32400 [9.5] 10100 [3.0] 14 11.5 1400 [660.7] 39000 [11.40] 3.6 9 24800 [7.30] 2.5
RP1448AJ1 RH1T4821STAN 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1525 [719.7] 46000 [13.50] 3.6 9 29800 [8.70] 2.6
RP1460BC1 RH1T6024STAN 56500 [16.6] 40900 [12.0] 15600 [4.6] 14 11.5 1800 [849.5] 54500 [15.97] 3.7 8.5 34600 [10.14] 2.6
RP1460BJ1 RH1T6024STAN 56500 [16.6] 40900 [12.0] 15600 [4.6] 14 11.5 1800 [849.5] 54500 [15.97] 3.7 8.5 34600 [10.14] 2.6

Note: Additional ratings and system match-ups can be accessed on MyRheem.com or the AHRI website (www.ahridirectory.org).

Guide Specifications

General

System Description: Outdoor-mounted, air-cooled, split-system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, composite basepan, an air-cooled coil, propeller-type condenser fan, suction and liquid line service valve, and a control box. Unit discharges supply air upward and is designed to match up with a coil unit.

Quality Assurance

Delivery, Storage, and Handling

Unit shipped as a single package; stored and handled per manufacturer's recommendations.

Warranty

U.S. and Canada only. Refer to product warranty certificate for complete details.

Products

Factory assembled, single piece, air-cooled heat pump unit containing all factory wiring, piping, controls, compressor, R-410A refrigerant charge, and special features prior to field start-up.

Unit Cabinet

Fans

Compressor

Condenser Coil

Refrigeration Components

Operating Characteristics

The unit's capacity will meet or exceed specified Btuh at a specified suction temperature. Power consumption at full load will not exceed specified kW. System SEER will be specified Btuh/watt or greater at DOE conditions.

Electrical Requirements

Special Features

Refer to accessory descriptions for specific features and available enhancements.

Limited Warranty

Rheem provides a replacement for any part that fails in normal use and service within the applicable period. A 10-year conditional parts warranty is offered, requiring registration. For complete details, contact a local contractor or the manufacturer for a copy of the product warranty certificate.

PDF preview unavailable. Download the PDF instead.

rheem rp1442cj1na article 1452525875452908 en ss ?fmt=pdf PDFium PDFium

Related Documents

Preview Rheem RP14 Classic Series Heat Pump: Features, Specifications, and Dimensions
Comprehensive guide to the Rheem RP14 Classic Series Heat Pump, detailing features, benefits, model specifications, electrical data, sound power levels, unit dimensions, clearances, control wiring, performance data, and warranty information.
Preview Rheem Classic Series RP14 Heat Pump Specifications and Features
Explore the Rheem Classic Series RP14 heat pump, detailing its energy efficiency (up to 14 SEER, 11.5 EER, 8.2 HSPF), various capacities, advanced features like scroll compressors and enhanced mufflers, and technical specifications for optimal home comfort and performance. Includes links to Rheem, AHRI, and Energy Star resources.
Preview Rheem Classic Series RP14 Heat Pump - Product Specifications
Detailed specifications and features for the Rheem Classic Series RP14 Heat Pump, including efficiency ratings, nominal sizes, cooling capacities, and technical data.
Preview Rheem Classic Series RP14 Heat Pump Specifications and Features
Detailed specifications, features, and performance data for the Rheem Classic Series RP14 Heat Pump, including various models and their technical attributes.
Preview Rheem Classic Series RP14 Heat Pump Specifications and Features
Detailed information on the Rheem Classic Series RP14 heat pump, including features, benefits, technical specifications, performance data, and installation guidelines.
Preview Rheem RP14 Piston Series Heat Pump: Specifications and Features
Detailed submittal sheet for Rheem RP14 Piston Series heat pumps, covering cooling and heating performance, electrical data, dimensions, and features. Available in 1.5 to 5 nominal tons with 14 SEER/11.5 EER efficiencies.
Preview Rheem Select Series WA14 Air Conditioners - Specifications and Performance Data
Detailed specifications, performance data, and installation guidelines for the Rheem Select Series WA14 air conditioners, including features, electrical and physical data, refrigerant line sizing, and warranty information.
Preview Rheem RA14 Series Air Conditioners: Features, Specifications, and Installation Guide
Comprehensive guide to Rheem's RA14 Series Air Conditioners, detailing features, technical specifications, model identification, and installation guidelines for efficient home comfort.