Cooper & Hunter Air Conditioner: CH-RES24-230VO + CH-R24MOLVWM-230VI
This document outlines the key features and technical specifications for the Cooper & Hunter air conditioning system, model combination CH-RES24-230VO + CH-R24MOLVWM-230VI.
Key Features
- Auto-Swing for horizontal louvers
- Genius Core ultra-low compressor speed of 12Hz
- 46°F Freeze Protection
- Smart Kit Ready
- Turbo Mode
- Follow Me Mode
- Smart kit Included
Specifications - Indoor Unit (CH-R24MOLVWM-230VI)
Parameter | Unit | Value |
---|---|---|
Power supply | V, Ph, Hz | 208-230V, 1Ph, 60 Hz |
Communication wiring | AWG 14-4 | |
Cooling Capacity | Btu/h | 24,000 (9,700 ~ 27,000) |
Cooling Input | w | 1,846 (860 ~ 2,550) |
Cooling Rated current | A | 8 (3.7 ~ 11.2) |
Heating at 47°F Capacity | Btu/h | 25,000 (11,300 ~ 32,700) |
Heating at 47°F Input | W | 2,379 (645 ~ 3,320) |
Heating at 47°F Rated current | A | 10.4 (3.5 ~ 14.5) |
COP | W/W | 3.08 |
HSPF4/HSPF2-4 | 10 | |
HSPF5/HSPF2-5 | 7.7 | |
Indoor fan motor Qty | 1 | |
Indoor fan motor Input | W | 58 |
Indoor fan motor RLA | A | 1.3 |
Indoor air flow (Turbo/Hi/Med/Lo) (No duct) | CFM | 759.3 / 588.6 / 459.1 / 382.6 |
ESP (range) | In.wg. | / |
Indoor noise level (Hi/Med/Lo) | dB(A) | 48.5 / 43.5 / 27.5 |
Dehumidification | L/H | 5.71 |
Indoor unit Dimensions (WxDxH) | inch | 42.60 x 9.21 x 13.27 |
Indoor unit Packing (WxDxH) | inch | 45.47 x 16.34 x 12.40 |
Indoor unit Net/Gross weight | lbs | 30.86 / 40.56 |
Drainage water pipe diameter | inch | 5 / 8" |
Refrigerant piping (Liquid side/Gas side) | inch | 3 / 8" / 5 / 8" |
Design pressure | PSIG | 550/340 |
Controller | remote controller | |
Room temperature Cooling | F | 60 ~ 90 |
Room temperature Heating | F | 32 ~ 86 |
Specifications - Outdoor Unit (CH-RES24-230VO)
Parameter | Unit | Value |
---|---|---|
Power supply | V, Ph, Hz | 208-230V, 1Ph, 60 Hz |
Min. circuit ampacity | A | 24 |
Max. fuse | A | 25 |
Compressor Model | KTM240D46UKT2 | |
Compressor Type | ROTARY | |
Compressor Brand | GMCC | |
Compressor Capacity | Btu/h | 25.93 |
Compressor Input | w | 2,045 |
Compressor Rated current (RLA) | A | 15.4 |
Refrigerant oil | oz | VG74 21 |
Outdoor fan motor Qty | 1 | |
Outdoor fan motor Input | w | 120 |
Outdoor fan motor RLA | A | 1 |
Outdoor fan motor Speed | r/min | 810/700/450 |
Outdoor air flow (Max) | CFM | 2,235.3 |
Outdoor noise level (Max) | dB(A) | 60 |
Throttle type | EXV+Throttle valve | |
Outdoor unit Dimensions (WxDxH) | inch | 37.24 x 16.14 x 31.89 |
Outdoor unit Packing (WxDxH) | inch | 42.91 x 19.68 x 34.84 |
Outdoor unit Net/Gross weight | lbs | 122.13/132.28 |
Refrigerant Type | R454B | |
Refrigerant Precharge | ft | 25 |
Additional charge for 1/4 inch liquid pipe | oz | / |
Additional charge for 3/8 inch liquid pipe | oz | 0.32 |
Refrigerant piping Liquid side/Gas side | inch | 3 / 8" / 5 / 8" |
Max. pipe length | ft | 164 |
Max. difference in level | ft | 82 |
Ambient temperature Cooling | F | -13 ~ 122 |
Ambient temperature Heating | F | -13 ~ 75 |
Installation Notes
Piping Exit Direction: Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. There are four options for the exit direction of the piping.
Wall Hole Size: When the gas side connective pipe is Φ (5/8in) 16mm or more, the wall hole should be (3-1/2in) 90mm.
Mounting Plate Dimensions: The indoor unit mounting plate has dimensions W (width) and H (height). Specific clearances are indicated: 6" (15cm) above, and 4-3/4" (12cm) on each side. The unit should be mounted 70" (180cm) from the floor.
General Notes
Cooper & Hunter products are subject to continuous improvements. Cooper & Hunter reserves the right to modify product design, specifications, and information in this data sheet without notice and without incurring any obligations. Actual unit design may differ from images shown in this submittal sheet.