Dometic NRX Refrigerator/Freezer Installation and Operation
This document provides essential information for the installation and operation of Dometic NRX series refrigerator and freezer units.
Models
The Dometic NRX series includes models such as:
- NRX 0050, 0060, 0080 (T)
- NRX 0035, 0050, 0060, 0080, 0115, 0130 (E/C/S)
- NRX 1035, 1050, 1060, 1080, 1115, 1130 (E/C/S)
Available configurations include Europe (E/C/S), America (E/C/T), and Asia/Pacific (C/S).
Power options include 12/24V and 100/240V AC.
Dimensions and Clearances
Refer to the following table for specific model dimensions and required clearances:
Model | A (mm/in) | B (mm/in) | C (mm/in) | D (mm/in) | W (mm/in) | H (mm/in) |
---|---|---|---|---|---|---|
NRX0035, NRX1035 | 380/15.0 | 480/18.9 | 525/20.7 | 355/14.0 | 534-536/21.0-21.1 | 392-394/15.4-15.5 |
NRX0050, NRX1050 | 380/15.0 | 510/20.1 | 525/20.7 | 355/14.0 | 534-536/21.0-21.1 | 392-394/15.4-15.5 |
NRX0060, NRX1060 | 448/17.6 | 537/21.1 | 525/20.7 | 355/14.0 | 460-462/18.1-18.2 | 534-536/21.0-21.1 |
NRX0080, NRX1080 | 475/18.7 | 537/21.1 | 625/24.6 | 355/14.0 | 487-489/19.2-19.3 | 634-636/25.0-25.0 |
NRX0115, NRX1115 | 525/20.7 | 568/22.4 | 745/29.3 | 355/14.0 | 537-539/21.1-21.2 | 754-756/29.7-29.8 |
NRX0130, NRX1130 | 525/20.7 | 568/22.4 | 812/32.0 | 355/14.0 | 537-539/21.2-21.2 | 821-823/32.3-32.4 |
Important Clearances:
- Minimum clearance of 50 mm (2 inches) is required for air circulation around the unit.
- Ensure adequate ventilation to prevent overheating and maintain cooling performance.
Installation Warnings
- Do not install near heat sources. [fire-symbol]
- Avoid direct sunlight. [sun-symbol]
- Ensure the unit is installed on a level surface. [level-symbol]
- Maximum tilt angle during operation is 30°. [degree-symbol]
- Maximum operating time on a tilt is 2 hours. [clock-symbol]
Electrical Connection
DC Connection (12V/24V):
Use appropriate cable cross-sections (Ø/mm²) based on cable length (l/m) for 12V and 24V systems. Refer to the diagram for recommended values (e.g., 10 mm² for 8m at 12V, 4 mm² for 8m at 24V).
Ensure correct polarity (+/-) when connecting.
AC Connection (100-240V):
Connect to a suitable AC power source. A residual current device (RCD) is recommended for safety.
Air Flow Requirements
Proper air circulation is crucial for optimal performance and longevity. Ensure minimum clearances of 50 mm (2 inches) at the rear (A) and sides (B) of the unit. Insufficient airflow can lead to reduced cooling efficiency and shortened lifespan.
Condensation Drain
The condensation drain system should be installed correctly to manage moisture. Ensure the drain tube is properly connected and routed.
Reversing the Door
The refrigerator door can be reversed to suit installation requirements. Follow these steps:
- Remove the bottom hinge and lift the door off.
- Remove the top hinge and transfer it to the opposite side.
- Transfer the door handle and latch mechanism.
- Mount the door with the new top hinge, then attach the bottom hinge.
- Ensure the door is properly aligned and closes securely.
Sliding Hinge Installation
For installations requiring a sliding hinge mechanism, follow these steps:
- Attach the sliding hinge components to the refrigerator and the cabinet.
- Ensure correct alignment and secure all fixings.
- Test the sliding mechanism for smooth operation.
Ensure clearances of 1-2 mm (0.04-0.08 in) for the sliding mechanism and a maximum of 40 mm (1.6 in) for the hinge mounting.
Fixing and Framing
Secure the unit within its intended frame or mounting location. Ensure all fixing points are stable and properly fastened.
More Information
For further details and company information, visit dometic.com.