ACTIVESHOP Gabbiano Standing Sauna with Active Ozone: User Manual & Operating Guide

ACTIVESHOP Gabbiano Standing Sauna with Active Ozone

Instructions for Use

Importer Information

Importer: ACTIVESHOP Sp. z o.o.

8b Graniczna St., building DC2A

54-610 Wroclaw, Poland

Website: www.activeshop.com.pl

Revision: A/11/2024

Product Overview

The Gabbiano stand sauna with active ozone is an innovative device designed for deep hair restoration. It utilizes warm steam generated by the humidifier/hair sauna to open the hair's micro-cells, facilitating better absorption of hair care preparations. This process involves opening the hair's scales and injecting conditioning agents, such as moisturizing agents (e.g., argan hair masks) or rebuilding agents (e.g., keratin ampoules or masks), to fill gaps in the hair structure. The active ozone cleanses the hair, removes chemical odors, and increases blood circulation to the scalp, offering a new dimension of hair care for clients.

Technical Specifications

Voltage 110/120V, 220/240V
Current 50/60Hz
Water Tank Capacity 2000ml
Drain Tank Capacity 350ml
Weight 32kg
Height 165cm
Base Dimensions 50cm x 70cm
Temperature Range 48-58°C
Control Manually controlled
Time Adjustment 0-60 minutes

Important Handling Note

The device should be carried using the handles. When lifting the helmet, do so carefully and do not force it open. Avoid shaking the device.

Installation

Fixing the Base and Device

  1. Remove the base from the carton and place it on the floor.
  2. Use two hands to lift the main unit of the device and place it onto the base.
  3. Secure the bracket using the stand flanges and tighten with a threaded bolt.

Diagram Description: The control panel is located on the upper part of the device, connected to the main unit which sits on an adjustable stand with wheels. Components include a water tank, handle, face shield, neck protector, and drain tank.

Control Panel Specifications

The control panel features the following:

  • "TIME" Button (Left): Increases time in 10-minute increments.
  • "TIMER" Display: Shows the selected time or remaining treatment time.
  • "TIME" Button (Right): Increases time in 1-minute increments.
  • Temperature Level Button: Adjusts steam temperature. Indicator lights show the selected level.
  • "On/Off" Button: Powers the device on or off.
  • "Cooling" Button: Activates the cooling function (indicated by a lamp above the button).
  • Mist Level Button: Adjusts mist intensity. Lamps on the left light up sequentially to indicate power level.

Display Indicators:

  • 23 (or similar number): Indicates selected or remaining treatment time.
  • PH: Heating is in progress.
  • HO: Indicates no water in the tank. Refill the tank with water (distilled water recommended).
  • OF: Indicates excess water in the tank. Turn off the device, remove the tank, refill to the appropriate level, and turn it back on.
  • COC102: Indicates that the cooling process is in progress.

Device Operating Instructions

1. Attaching the Face Shield to the Helmet

  1. Loosen the strap at the bottom of the visor.
  2. Attach the cowl to the center frame of the helmet using the two hooks at the top, covering from top to bottom.
  3. Tighten the strap at the bottom of the cowl. Adjust the top position of the strap to align with the front edge of the helmet. Opening the upper strap allows positioning for the customer's head.

2. Fitting the Device

Ensure the client is seated comfortably before turning on the device.

  1. Position the device: Place the device behind the client.
  2. Loosen the height adjustment knob so that the neck drapes meet the client's neck.
  3. Open the top cover and lower the helmet, checking the client's position.

3. Adjusting the Face Shield

  1. Adjust the face shield from inside the helmet to position it over the client's turban. Ensure it is inserted from the neck nap to avoid covering the client's face.
  2. Tighten the crossed straps from inside the helmet and adjust them to the face shield. Tighten until the face shield stops at the top of the turban (refer to diagram for placement over the towel).

4. Closing the Lower Cover

  1. Adjust the cover so its distance to the turban is even.
  2. Ensure there is no space between the client's face shield and their head.
  3. Slowly close the lower cover.
  4. Press firmly so that the left and right sides close with a characteristic "click".

5. Switching the Device On/Off

  1. Plug the device into an electrical outlet.
  2. Press the "Start/Stop" button to turn the device on.
  3. To turn off, repeat step "B".
  4. When the device is not in use, disconnect the power supply.

6. Operating Mode Settings

Select one operation mode from the control panel's center: "Treatment 1" (automatic), "Treatment 2" (automatic), or "Manual".

Mode Level Spraying Level Temperature Operating Time Time Cooling
"Treatment 1" 4 4 8 minutes 3 minutes
"Treatment 2" 3 3 10 minutes 3 minutes
"Manual" 2 2 12 minutes 3 minutes

The device requires spray, temperature, and time conditions to be selected before starting. Pressing the "Start/Stop" button initiates operation based on the last settings. If the water is cold, steam generation may take longer.

Temperature Level Adjustment

Use the temperature level button to change the steam temperature. Pressing the button increases the temperature, starting from level "0".

Level Temperature
0 -
1 ~45°C
2 ~47°C
3 ~49°C
4 ~51°C
5 ~53°C

Note: Do not change the temperature during heating (indicated by flashing PH light). Allow the water to heat up after adding water.

Device Operation Details

During the selected mode, the display and lamps will flash alternately, showing the remaining time. Mode settings and parameters (time, spray level, temperature, cooling) can be adjusted using the respective buttons. Setting the operating time to "0" will terminate spraying. To stop the device, press the "START/STOP" button; the light will flash. Settings can be changed during a pause. If a mode change occurs, operation resumes in the new mode. Pressing "START/STOP" again resumes operation. Upon completion, an alarm sounds, the timer displays "0", and the cooling process begins. After cooling, another alarm sounds (5 beeps), and the display shows "0".

Removing the Face Cover

  1. Open the top cover.
  2. Press the fastening button and loosen the crossed straps.
  3. Loosen the cowl and remove it from the client's head.
  4. Close the top cover, then lift the helmet and push the device away.

Note: Ensure the face shield is removed before lifting the helmet.

Cleaning the Device

Emptying the Drain Tank

  1. Lift the helmet.
  2. Unscrew the valve holding the drain tank.
  3. Grasp the bottom of the tank and pull it downward.
  4. Empty the tank.
  5. To refill with water, proceed in reverse order.
  6. When installing the tank, ensure the drain hose is inside.

Note: Add water so that the level does not exceed the top line.

Draining Water from the Internal Section After Treatment

  1. Remove the water tank and empty any remaining water. Wash the tank.
  2. Turn the valve 90 degrees to the right to pour out water from the device.

Note: If using chemicals for cleaning, ensure they are washed off completely.

Diagram Description: The device features a water tank with a cap, a drain outlet, a handle, an on/off switch, height adjustment, a neck protector, a tissue dispenser, and a drain tank located at the base. The helmet assembly includes the control panel and face shield.

Note: If water spills on any metal part or the control panel, immediately wipe it with a dry cloth. Flooding can cause permanent damage and unit failure.

Maintenance

  • The inside of the helmet gets dirty easily and requires regular cleaning. Chemical soiling can lead to dysfunction and unpleasant odors.
  • During treatment, chemicals may contact the device. Immediately wipe away dirt with a damp cloth.
  • Do not use alcohol, gasoline, solvents, kerosene, abrasive waxes, or saturated sponges for cleaning.

Caution: Wash the face protector with chemicals, but always use it only when dry.

Recommendations

  1. Disconnect power when the product is not in use.
  2. Unplug the device when cleaning it.
  3. The device is not a toy. Children should be supervised to ensure they do not play with it.
  4. Do not interfere with the device's design or attempt to change its parameters or construction.
  5. Cleaning and maintenance must not be performed by children without adult supervision.

Problems and Their Solutions

  • Mist Not Spraying: Check the display for icons (PH, HO, OF) and consult their meanings.
  • Temperature Too High or Too Low: Ensure the temperature level has been selected correctly. Note: During continuous use, temperatures may exceed indicated levels; allow the unit to cool down.
  • Water Leaks from Drain Hole: Verify that the drain valve is closed.
  • Device Has No Power: Check if the plug is properly connected to the electrical outlet, check fuses, ensure the appliance is turned on, and try removing and reconnecting the plug.

Safety Measures

  • This is professional equipment for beauty parlors. Operation should be by qualified cosmetic personnel to avoid undesirable consequences.
  • Do not disassemble the device or use it for purposes other than those stated in this manual. All servicing and repairs must be performed by an authorized ACTIVESHOP Ltd. service technician.
  • Do not install or operate the device near liquids, in wet places, or with wet hands to prevent liquids from entering the device.
  • Immediately unplug the device and contact authorized service if:
    • Liquid has entered the device.
    • The device emits a strange odor, smoke, or strange sounds.
    • The power cord is damaged.
    • The device has been overturned or its housing is damaged.
  • Do not place objects on cables. Do not install the device where the power cord may be stepped on.
  • For safety, unplug the power cord from the outlet after finishing work with the device.
  • Do not insert foreign objects into the device's openings. If an object enters, remove the cord from the outlet and contact the distributor or manufacturer.
  • Do not place the device on unstable carts, shelves, or vehicles, as dropping may cause damage.
  • To ensure the device's useful life, maintain a one-minute interval before pressing the power button again (between switching on/off).
  • The power supply must comply with the specifications on the nameplate to prevent incorrect operation, damage, or burning.

Caution:

  • In case of damage to the power cord or other malfunctions, contact an authorized service center to avoid danger.
  • This device can be used by children aged 8 years and older, and by individuals with reduced physical/mental capabilities or lack of experience, provided they are supervised and instructed on safe usage and associated risks.
  • The equipment is not intended for play by children. Do not allow children to play with it.
  • Do not leave the equipment unsupervised when children or persons without sufficient knowledge are nearby.
  • This electrical appliance is not a toy. Incorrect use can pose health risks or lead to death; use and store it out of children's reach.

Disposal of the Device

Dispose of used electrical appliances, fixtures, and packaging at raw material reprocessing centers in accordance with environmental protection principles. Do not dispose of electrical appliances in household waste containers. Follow the rules for discarding this type of equipment, adhering to Directive 2012/19/EC concerning waste electrical and electronic equipment.

Electrical equipment should be collected separately and handed over to collection points for waste electronic and electrical equipment. At the end of their useful life, old appliances contain recyclable components and should be handed over for recycling to appropriate collection points or ACTIVESHOP Ltd.

Storage and Transport

The device should be transported in its original packaging within a temperature range of -20°C to +40°C. Store the device in a well-ventilated room with a relative humidity not exceeding 90%. The operating temperature range is +10°C to +40°C. During storage and transportation, the device must not be thrown, dropped, or exposed to mechanical shocks or weathering.

Models: Standing Sauna with Active Ozone, Sauna with Active Ozone, Active Ozone, Ozone

File Info : application/pdf, 7 Pages, 450.72KB

PDF preview unavailable. Download the PDF instead.

126314 manual en

References

Aspose.Words for .NET 25.2.0

Related Documents

Preview Gabbiano Standing Hair Sauna with Active Ozone - User Manual
Comprehensive user manual for the ACTIVESHOP Gabbiano standing hair sauna with active ozone. Learn about its features, technical specifications, operation, maintenance, and safety guidelines for professional hair care.
Preview GABBIANO INFRAZONE Y-707 User Manual - ACTIVESHOP Professional Hair Steamer
Comprehensive user manual for the ACTIVESHOP GABBIANO INFRAZONE Y-707 professional hair steamer. Includes operating instructions, features, technical specifications, safety precautions, maintenance, and disposal guidelines.
Preview ACTIVESHOP Giovanni D-09 Vapozone DT-8228 White User Manual and Instructions
Comprehensive user manual for the ACTIVESHOP Giovanni D-09 Vapozone (Model: DT-8228 White). This guide details setup, operation, features like hot steam and ozone, technical specifications, safety precautions, and proper disposal for salon and professional use.
Preview ACTIVESHOP Giovanni Mini F-17 Vapozone User Manual
User manual for the ACTIVESHOP Giovanni Mini F-17 Vapozone, providing instructions for use, technical specifications, safety guidelines, and maintenance information for this facial steamer.
Preview ACTIVESHOP Gabbiano Head Spa Couch 017: Instructions for Use and Safety
Detailed instructions for the ACTIVESHOP Gabbiano Head Spa Couch 017. This guide covers mounting, operation, usage tips, frequently asked questions, important safety measures, technical specifications, and proper disposal. Essential for beauty salons and spa professionals.
Preview ACTIVESHOP Giovanni D-21 Vapozoon with Magnifying Lamp User Manual
Comprehensive user manual for the ACTIVESHOP Giovanni D-21 Vapozoon, a multifunctional facial steamer with a magnifying lamp, detailing its functions, specifications, assembly, operation, safety, and maintenance.
Preview ACTIVESHOP Giovanni D-21 Vapozone with Magnifying Glass Lamp: Operating Instructions
Comprehensive operating instructions for the ACTIVESHOP Giovanni D-21 vapozone, a multifunctional beauty salon device with warm steam and ozone, featuring a magnifying glass lamp. Includes specifications, safety measures, installation, and usage guidelines.
Preview ACTIVESHOP Giovanni D-09 Vapozone DT-8228 White - User Manual and Instructions
Detailed user manual for the ACTIVESHOP Giovanni D-09 Vapozone (Model: DT-8228 White), providing instructions for use, technical specifications, safety precautions, and maintenance. Learn how to effectively use this facial steamer for skin treatments.