KeepRite "C" Generation Condensing Units - Price List
Effective Date: 01 March 2023
Supersedes: KLP-2022-3
Product Overview
This document details the KeepRite "C" Generation of Indoor and Outdoor Air Cooled Condensing Units, encompassing the KEH, KEZ, and KES lines. These units are designed for refrigeration applications and are available with various compressor types (Hermetic, Scroll, Semi-Hermetic) and refrigerants.
Prices are F.O.B. shipping point. Freight is allowed via lowest common carrier to the nearest freight station in Canada and U.S.A. (except Alaska or Hawaii) on shipments of $7000 NET or more. Shipments under $7000 NET are F.O.B. shipping point and not freight allowed. Prices, weights, and specifications are subject to change without notice. Terms are Net 30 days.
The units include models for DOE & NRCAN AWEF-EXEMPT applications.
Product Lines
- KEH - Line: Indoor / Outdoor Air Cooled Hermetic Condensing Units
- KEZ - Line: Indoor / Outdoor Air Cooled Scroll Condensing Units
- KES - Line: Indoor / Outdoor Air Cooled Semi-Hermetic Condensing Units
- KE* - Line: Condensing Units, Factory Installed Options
KEH-Line: "C" Generation Hermetic Condensing Units
Nomenclature: KEH A 010 M 8 - HT3 C-A
Model Series: KEH = Excel Hermetic Air Cooled Condensing Unit Line
Compressor Manufacturer: A = Copeland
Nominal HP: 006 = 1/2 HP, 010 = 1 HP, 015 = 1.5 HP, 020 = 2 HP, 021 = 2 HP, 025 = 2.5 HP, 030 = 3 HP
Application Range: L = Low Temp, M = Medium Temp
Refrigerant: 6 = R404A / R507
Enclosure: H = Outdoor, I = Indoor
Voltage: S2 = 208/230-1-60, S6 = 200/220-1-50, S7 = 200-1-50, T3 = 208/230-3-60, T4 = 460-3-60, T5 = 575-3-60, T7 = 200/220-3-50, T9 = 380/400-3-50
Design Generation: C = "C" Generation
Standard Features (Indoor Unit):
- Weatherproof electrical control box with compressor contactor and fused control circuit.
- Welded-hermetic compressor.
- High efficiency enhanced tube and fin condenser design.
- Pre-formed piping.
- Quiet fan motor operation.
- Energy efficient PSC condenser fan motor.
- Electrical control panel away from air flow stream.
- Wide-open front design, spring latches and handle on 5Hp MT & HT or larger.
- Unit leak tested and shipped with helium holding charge.
- Painted cabinet.
- Receiver with fusible plug and liquid shut off valve.
- Suction service valve.
- Copper tubing secured with cushion clamps.
- Fixed high and low pressure control.
Standard Features (Outdoor Unit): Includes all Indoor Unit features plus:
- Painted weather-resistant housing with removable hood.
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency.
- Crankcase heater.
Available Options:
- Sealed suction filter.
- Suction accumulator.
- Suction accumulator with boil-out coil.
- Heated and insulated receiver.
- Sealed liquid line filter drier and sight glass.
- Liquid line solenoid valve with 230-volt coil (shipped loose).
- Compressor circuit breaker.
- Compressor time delay relay.
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details).
- QuickVac Evacuation and Refrigerant Recovery Valves.
- SmartSpeed Fan Motor Technology.
- Pump down toggle switch.
- Electric defrost kit with mechanical time clock and contactors, as required.
- Hoffman variable fan speed control.
- Lockout control circuit relay (for liquid solenoid valve).
- Disconnect switch (fused or non-fused).
- Electronic phase / voltage monitor.
- Leg kit or air discharge hood.
See pages 17-19 for complete details of available factory installed options.
KEZ-Line: "C" Generation Scroll Condensing Units
Nomenclature: KEZ A 075 H 8 - HT4 C-A
Model Series: KEZ = Excel Scroll Air Cooled Condensing Unit Line
Compressor Manufacturer: A = Copeland
Nominal HP: 007 = 3/4 HP, 010 = 1 HP, 015 = 1.5 HP, 020 = 2 HP, 021 = 2 HP, 025 = 2.5 HP, 030 = 3 HP, 035 = 3.5 HP, 040 = 4 HP, 045 = 4.5 HP, 055 = 5.5 HP, 060 = 6 HP, 061 = 6 HP, 075 = 7.5 HP, 090 = 9 HP, 100 = 10 HP, 120 = 12 HP, 130 = 13 HP, 150 = 15 HP, 170 = 17 HP.
Application Range: L = Low Temp
Refrigerant: 8 = R407A, R407C, R448A, R22, R404A, R507
Enclosure: H = Outdoor, I = Indoor
Voltage: S2 = 208/230-1-60, S3 = 230-1-60, S6 = 200/220-1-50, S7 = 200-1-50, T3 = 208/230-3-60, T4 = 460-3-60, T5 = 575-3-60, T7 = 200/220-3-50, T9 = 380/400-3-50
Design Generation: C = "C" Generation
Standard Features (Indoor Unit):
- Compatible with Low GWP Refrigerants.
- Weatherproof electrical control box with compressor contactor and fused control circuit.
- Copeland scroll compressor.
- High efficiency enhanced tube and fin condenser design.
- Energy efficient PSC condenser fan motor.
- Receiver with fusible plug and liquid shut off valve.
- Suction service valve.
- Pre-formed copper tubing.
- Liquid injection (low temp. models).
- Unit leak tested and shipped with helium holding charge.
- Fixed high pressure switch and adjustable low pressure control.
- Receiver inlet valve on 2-fan units models only.
- Discharge thermostat on applicable models only.
- Painted cabinet.
- Anti-short cycle time delay relay.
Standard Features (Outdoor Unit): Includes all Indoor Unit features plus:
- Painted weather-resistant housing with removable hood.
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency.
- Crankcase heater.
- Fan cycling control with flex hose (2 fan units).
Available Options:
- Suction accumulator with and without boil-out coil.
- Discharge line check valve.
- Oil separator with and without oil return filter and solenoid valve.
- Adjustable flooded head pressure control valves.
- Receiver inlet ball valve.
- Heated and Insulated receiver.
- Over-sized receiver.
- Sealed liquid line filter drier & sight-glass.
- Ball valve - liquid line (shipped loose).
- Insulated suction lines.
- Leg kits.
- Discharge air hood.
- Sub cooling circuit on 5 - 17 HP models.
- Liquid line solenoid valve (with standard 230 volt coil) - shipped loose.
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details).
- QuickVac Evacuation and Refrigerant Recovery Valves.
- Dual pressure control with flex hoses.
- Compressor circuit breaker.
- Current sensing relay - for use with oil safety control (where applicable).
- Defrost heater contactor c/w fuse block.
- Evaporator fan contactor c/w fuse block.
- Disconnect switch.
- Disconnect fusing.
- Pump down toggle switch.
- Lock out control circuit relay.
- Hoffmann speed control for condenser fan (replaces flooded valve).
- Time delay relay for compressor.
- Mechanical time clock.
- Electronic voltage / Phase monitor.
- SmartSpeed Fan Motor Technology.
- Limitrol+ Floating Head Pressure Control System (see Bulletin K40-LIMITROL-AG or https://docs.k-rp.com/1101113.pdf for details).
See pages 17-19 for complete details of available factory installed options.
KES-Line: "C" Generation Semi-Hermetic Condensing Units
Nomenclature: KES A 075 H 8 - HT4 C-A
Model Series: KES = Excel Semi-Hermetic Air Cooled Condensing Unit Line
Compressor Manufacturer: A = Copeland, B = Bitzer
Nominal HP: 015 = 1.5 HP, 020 = 2 HP, 021 = 2 HP, 025 = 2.5 HP, 030 = 3 HP, 031 = 3.1 HP, 035 = 3.5 HP, 039 = 3.9 HP, 050 = 5 HP, 060 = 6 HP, 061 = 6 HP, 080 = 8 HP, 100 = 10 HP, 120 = 12 HP.
Application Range: L = Low Temp, M = Medium Temp
Refrigerant: 6 = R404A, R507, 8 = R407A, R407C, R22, R404A, R507, R448
Enclosure: H = Outdoor, I = Indoor
Voltage: S2 = 208/230-1-60, S3 = 230-1-60, S6 = 200/220-1-50, S7 = 200-1-50, T3 = 208/230-3-60, T4 = 460-3-60, T5 = 575-3-60, T7 = 200/220-3-50, T9 = 380/400-3-50
Design Generation: C = "C" Generation
Standard Features (Indoor Unit):
- Compatible with Low GWP Refrigerants.
- Weatherproof electrical control box with compressor contactor and fused control circuit.
- Spring mounted accessible semi-hermetic compressor with suction and discharge vibration eliminator.
- High efficiency enhanced tube and fin condenser design.
- Energy efficient PSC condenser fan motor.
- Receiver with fusible plug and liquid shut off valve.
- Fixed high pressure switch and adjustable low pressure control.
- Receiver inlet and outlet shutoff valve (8HP and above).
- Suction service valve.
- Pre-formed copper tubing.
- Unit leak tested and shipped with Helium holding charge.
- Electronic liquid injection on L8 units.
- Painted cabinet.
Standard Features (Outdoor Unit): Includes all Indoor Unit features plus:
- Painted outdoor weather-resistant housing with removable hood.
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency.
- Adjustable head pressure control on large 2 fan models.
- Crankcase heater.
- Fan cycling control (all 2 fan models).
Available Options:
- Suction accumulator.
- Suction accumulator with boil-out coil.
- Discharge line Check valve.
- Oil separator.
- Oil separator c/w oil return filter & solenoid valve.
- Adjustable head pressure control valves.
- Receiver inlet ball valve (standard on 2 fan models).
- Heated and Insulated receiver.
- Over-sized receiver.
- Sealed liquid line filter drier & sight-glass.
- Ball valve - liquid line (shipped loose).
- Insulated suction lines.
- Leg Kits.
- Discharge air hood.
- Sub cooling circuit on 5 - 22 HP models.
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details).
- QuickVac Evacuation and Refrigerant Recovery Valves.
- Liquid line solenoid valve-(with standard 230 volt coil)-shipped loose.
- Compressor Circuit breaker.
- Current sensing relay - for use with Oil safety control (where applicable).
- Defrost heater contactor c/w fuse block.
- Evaporator Fan contactor c/w fuse block.
- Disconnect switch.
- Disconnect Fusing.
- Pump down toggle switch.
- Lock out control circuit.
- Hoffmann Speed control for condenser fan (replaces flooded valve).
- Time delay relay for compressor.
- Mechanical Time Clock.
- Defrost Kit.
- Electronic Voltage/Phase Monitor.
- SmartSpeed Fan Motor Technology (see page 4).
- Limitrol+ Floating Head Pressure Control System (see page 5 or Bulletin K40-HPC-AG or https://docs.k-rp.com/1101113.pdf for details).
See pages 17-19 for complete details of available factory installed options.
Factory Installed Options
KeepRite offers various factory-installed option packages for their "C" Generation Condensing Units. These packages are designed to enhance performance and functionality.
Option Packages - All Compressor Models
Option Package | HP (Size) | Price (STD.) |
---|---|---|
Package "A" STANDARD UNIT includes: High efficiency PSC fan motors, Fan Guard, Enhanced tube condenser coil, Copper tubing secured with cushion clamps, Receiver outlet valve, Flooded head pressure control (STD on Outdoor models), Crankcase heater (STD on Outdoor models). | All MODELS | 656 |
Package "B" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass. | 0.5 - 2.9 3.0-12 15 + |
2064 2555 3467 |
Package "C" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Electric Defrost Kit* (40A max on Htrs) + Suction accumulator. | 0.5 - 2.9 3.0-7.5 7.6-12 15 + |
1110 1761 2115 2576 |
Package "D" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Heated and insulated receiver. | 0.5 - 2.9 3.0-7.5 7.6-12 15 + |
2518 3553 5108 6092 |
Package "E" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Electric Defrost Kit* (40A max on Htrs) + Suction accumulator + Heated and insulated receiver. | 0.5 - 2.9 3.0-7.5 7.6-12 15 + |
1538 1644 1932 N/A |
Package "F" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Electric Defrost Kit* (40A max on Htrs). | 0.5 - 2.9 3.0-12 15 + |
1991 2642 2996 |
Package "G" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Electric Defrost Kit* (40A max on Htrs) + Heated and insulated receiver. | 0.5-2.9 3.0-7.5 7.6-12 15 + |
1356 1462 1750 N/A |
Package "H" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Timeclock. | 0.5 - 2.9 3.0-12 15 + |
1637 2672 3939 |
Package "J" includes: All items in Package "A" + Sealed liquid line filter drier and sight glass + Heated and insulated receiver + Suction accumulator. | 0.5 - 2.9 3.0 - 7.5 7.6-12 15 + |
5211 N/A N/A N/A |
*Electric Defrost Kit includes: Timeclock, defrost heater contactor (40A max.) and fan motor contactor (30A if required depending on matched evaporator).
Individual Options
Individual Options | HP (Size) | List Price $ | Individual Options | HP (Size) | List Price $ |
---|---|---|---|---|---|
Cabinet A | 530 | Adjustable pressure controls with flex hose | All Models | 384 | |
Cabinet B | 649 | Adj Dual Pressure Control (Danfoss) | All Models | 847 | |
Cabinet C | 762 | Adj Dual Pressure Control (Johnson) | All Models | 1168 | |
Cabinet D | 1398 | Separate Johnson Low Pressure and High Pressure Controls | All Models | 298 | |
Cabinet E | 1539 | Ball valve (Shipped loose) | All Models | 765 | |
Cabinet F | 1914 | Current Sensing Relay (for use w/oil safety control) | All Models | 765 | |
Sealed liquid line filter drier and sight glass | 0.5-2.9 3.0 - 12 15 + |
656 763 1051 |
Compressor circuit breaker | 0.5 -4.0 5.0 - 7.5 7.6 + |
1587 2972 4614 |
Replaceable Core liquid line filter drier and sight glass | 2.9 - 12 15 + |
1073 1312 |
Compressor time delay relay | All Models | 391 |
Suction accumulator without heat exchanger | 0.5-2.9 3.0-7.5 7.6-12 15 + |
527 912 1824 2635 |
Pump down toggle switch | All Models | 298 |
Suction accumulator with heat exchanger | 0.5 - 2.9 3.0-7.5 7.6-12 15 + |
738 1264 2527 4781 |
Lock-out control circuit (for liquid line solenoid) | All Models | 1088 |
Sealed suction filter | 0.5 - 2.9 3.0-7.5 7.6-12 15 + |
421 592 1072 1389 |
Mechanical Time Clock | All Models | 700 |
Replaceable core suction filter | 2.9-7.5 7.6 - 12 15 + |
1139 1394 2475 |
30A or 40A Contactor | All Models | 442 |
Discharge line check valve | 0.5 - 6.1 7.6-12 15 + |
515 708 771 |
60A Contactor | All Models | 608 |
Two valve adjustable flooded head pressure control | All Models | 794 | Electric Defrost Kit*: 1 Evap per Compressor | Up to 40A Htr, 30A Fans Up to 60A Htr, 30A Fans Up to 80A Htr, 30A Fans |
881 1048 2283 |
Oil separator | 2.9-7.5 7.6-22 |
1258 1769 |
Electric Defrost Kit*: 2 Evaps per Compressor | Up to 40A Htr, 30A Fans Up to 60A Htr, 30A Fans |
1323 1645 |
Oil separator c/w oil filter and solenoid valve | 2.9-4.0 5.0 - 7.5 20 + |
1590 1665 2537 |
Electric Defrost Kit*: 3 Evaps per Compressor | Up to 60A Htr, 30A Fans Up to 80A Htr, 30A Fans |
3222 3318 |
Oversized Receiver | 0.5-2.9 3.0-12 15 + |
995 1210 1352 |
Hoffman variable fan speed control (replaces flooding valve) Recommended for use in mild ambients only | All Models | 2687 |
Heated and insulated receiver | 0.5 - 2.9 3.0-7.5 7.6 - 12 15 + |
453 998 1353 1526 |
Non-fused disconnect | 208-230 460-575 |
834 975 |
Receiver inlet ball valve | 7.5 HP and below | 579 | Disconnect fusing | All Models | 493 |
Liquid line solenoid valve with 230 volt coil (Shipped loose) | 0.5 -5.0 6.0-7.6 8+ |
650 727 1192 |
3-Lead Phase / voltage monitor | All Models | 696 |
6-Lead Phase / voltage monitor | All Models | 1381 | |||
Discharge Air Hood (Angled front) | Cabinet A Cabinet B Cabinet C Cabinet D Cabinet E Cabinet F |
467 498 525 609 653 730 |
|||
Hail Guard (Angled Condenser Cover) OR Wind Guard (if required, used only with ECM on open roof) | |||||
8" Leg Kit (factory mounted) | 0.5 - 2.9 3.0-7.5 7.6 + |
389 504 756 |
Optional Fin Material/Coatings - Horizontal Air Cooled Condensing Units
CABINET | CABINET SIZE * | "Gold Coat Fin" | Copper Fin | E-COAT |
---|---|---|---|---|
A | 767 | 6188 | ||
B | 1157 | 6188 | ||
C | 1545 | Consult Factory for Pricing | 7842 | |
D | 1644 | 8628 | ||
E | 2003 | 9095 | ||
F | 2620 | 10403 |
LIMITROL FOR KE-LINE CONDENSING UNITS
CABINET | VOLTAGE | LIMITROL | LIMITROL WITH HEATED & INSULATED RECEIVER | LIMITROL WITH HEATED & INSULATED RECEIVER WITH WIND GUARD | |
---|---|---|---|---|---|
CABINETS A, B, C | 230V 460V/575V |
- | 3830 5122 |
4828 6121 |
5909 7201 |
CABINET D | 230V 460V/575V |
5808 7057 |
7160 8409 |
8265 9514 |
|
CABINET E | 230V 460V/575V |
7454 10343 |
8978 11868 |
10160 13049 |
|
CABINET F | 230V 460V/575V |
10343 11868 |
11868 13049 |
13049 N/A |
EC MOTORS FOR KE-LINE CONDENSING UNITS
CABINET | SMARTSPEED™ (see table below) | VARIABLE SPEED | ||
---|---|---|---|---|
230V | 230V | 460V | 575V | |
A | 290 | 515 | 2189 | 2189 |
B | 441 | 762 | 2629 | 2629 |
C | 441 | 693 | 1206 | 2560 |
D | 441 | 693 | 1206 | 2560 |
E | 882 | 1227 | 2255 | 4515 |
F | 1461 | 1744 | 2402 | 5032 |
Compressor Model Cross-Reference
HERMETIC
MODEL (Copeland) | CHASSIS |
---|---|
KEHA006M8 | A |
KEHA008M8 | A |
KEHA009M8 | A |
KEHA010M8 | A |
KEHA011M8 | B |
KEHA013M8 | B |
KEHA015M6 | B |
KEHA020M6 | B |
KEHA025M6 | C |
KEHA029M6 | C |
KEHA030M6 | C |
KEHA035M6 | D |
KEHA006L6 | D |
KEHA008L6 | D |
KEHA010L6 | A |
KEHA015L6 | E |
KEHA020L6 | E |
KEHA025L6 | B |
KEHA030L6 | B |
SCROLL
MODEL (Copeland) | CHASSIS |
---|---|
KEZA008L8 | A |
KEZA010L8 | A |
KEZA015L8 | A |
KEZA020L8 | B |
KEZA025L8 | B |
KEZA030L8 | B |
KEZA035L8 | C |
KEZA040L8 | C |
KEZA045L8 | C |
KEZA055L8 | C |
KEZA060L8 | C |
KEZA075L8 | D |
KEZA085L8 | D |
KEZA100L8 | E |
KEZA130L8 | E |
KEZA150L8 | E |
KEZA170L8 | F |
KEZA220L8 | F |
SEMI-HERMETIC
MODEL (Copeland) | MODEL (Bitzer) | CHASSIS |
---|---|---|
KESA005L8 | KESB010L 6/8 | A |
KESA008L8 | KESB015L 6/8 | A |
KESA010L8 | KESB020L 6/8 | A |
KESA015L8 | KESB025L 6/8 | B |
KESA020L8 | KESB030L 6/8 | B |
KESA021L8 | KESB031L 6/8 | B |
KESA030L8 | KESB039L 6/8 | C |
KESA032L8 | KESB050L 6/8 | C |
KESA035L 6/8 | KESB060L 6/8 | C |
KESA040L 6/8 | KESB080L 6/8 | D |
KESA060L 6/8 | KESB100L 6/8 | E |
KESA061L 6/8 | KESB120L 6/8 | E |
KESA075L 6/8 | F | |
KESA090L 6/8 | F | |
KESA100L 6/8 | ||
KESA120L 6/8 | ||
KESA130L 6/8 | ||
KESA150L 6/8 | ||
KESA220L 6/8 |
Product Support Resources
- Product Support: web: www.k-rp.com/support, email: smcu@k-rp.com, call: 1-844-893-3222 x521
- Troubleshooting: email: troubleshooting@k-rp.com, call: 1-844-893-3222 x529
- Service Parts: web: www.k-rp.com/parts, email: parts@k-rp.com, call: 1-844-893-3222 x504
- Warranty: web: www.k-rp.com/warranty, email: warranty@k-rp.com, call: 1-844-893-3222 x507
- Orders: email: orders@k-rp.com, call: 1-844-893-3222 x501
- Shipping: email: shipping@k-rp.com, call: 1-844-893-3222 x503
KeepRite Refrigeration, Brantford, ON • Longview, TX
1-800-463-9517 info@k-rp.com www.k-rp.com
Due to the manufacturer's policy of continuous product improvement, we reserve the right to make changes without notice.