Section A: Safety Information
Read these instructions carefully before use and keep them for future reference. Provide them to anyone who will use this product. Failure to follow these instructions may lead to serious property damage and severe personal injury.
- ONLY use the red coupler on the HIGH-PRESSURE service port.
- ONLY use the blue coupler on the LOW-PRESSURE port. Using them interchangeably may cause severe property damage and serious personal injuries.
- Turn your air-conditioning system off before evacuation.
- DO NOT let children or individuals with compromised physical or mental capabilities use this product. DO NOT allow people unfamiliar with this product or these instructions to operate it.
- DO NOT use this product if it is damaged or malfunctions. Repair or replace damaged components before further use.
- ALWAYS use with proper personal protective equipment such as a dust mask, goggles, and work gloves in a well-ventilated place, as these refrigerants can irritate your eyes, nose, throat, and skin or cause frostbite, heart arrhythmia, unconsciousness, and even death. Further, operating your vehicle in a closed environment may result in carbon monoxide poisoning and other problems. If you begin to develop symptoms such as headaches, dizziness, or nausea during use of this product, turn off your vehicle and get fresh air IMMEDIATELY. Do not continue work until the vehicle has been moved to an area with better ventilation.
- Use EXTREME caution when disconnecting the hoses after use, as they may still contain some refrigerant under pressure.
Section B: Specifications
R410a, R32, R134a, R22 | |
---|---|
Low Pressure Gauge Range | -15° to 550 psi (-1 to 38 Bars) |
High Pressure Gauge Range | -15° to 800 psi (-1 to 55 Bars) |
Hoses | Length: 4.9 ft. (1.5 m), Diameter: 1/4 in. (6.3 mm) |
Case Dimensions | 12.2 × 11.8 × 3.4 in. (31 x 30 x 8.5 cm) |
Net Weight | 6.5 lb. (3 kg) |
Section C: Manifold Gauge Set Instructions
Components:
- 4 Way Manifold Gauge *1
- Hose *4 (High-Pressure Hose (Red), Low-Pressure Hose (Blue), Charging Hose (Yellow), Evacuation Hose (Black))
Included Parts & Fittings:
- "R134a&R404a refrigerant Quick Coupler *2
- Red - High Pressure; Blue - Low Pressure
- Valve Core Tool *1
- Sealing-self Refrigerant Can Tap *2
- Conversion Fittings *2 (1/4" SAE External to 5/16" SAE Internal Adapter, 1/4" SAE External to 1/2" ACME Internal Adapter)
- Spare Parts *1 (Pipe Sealing Rings *3, Valve Core *1)
- Screwdriver *1
- Teflon Tape *1
- Thread Conversion Adapter *1
General Safety Instructions:
ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS UNIT. MOST STATES, COUNTRIES, ETC. MAY REQUIRE THAT THE USER BE LICENSED. PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.
Danger - Avoid breathing refrigerant vapors and lubricant vapors or mist. Breathing at high concentration levels may cause heart arrhythmia, loss of consciousness, or even suffocation. Exposure may irritate the eyes, nose, throat, and skin. Please read the manufacturer's Material Safety Data Sheet for further safety information on refrigerants and lubricants.
Danger - EXPLOSION RISK. Use extreme caution when working with flammable refrigerants. Never use this manifold with oxygen.
Danger - EXPLOSION/RUPTURE RISK. DO NOT use this manifold with unregulated nitrogen, carbon dioxide, or other very high-pressure gases. Unregulated gases can cause components in a refrigeration system to rupture. Severe injury or death can occur.
Caution - All hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frostbite or other related injuries. Wear proper personal protective equipment, such as safety goggles and gloves. When disconnecting any hose, please consider using extreme caution.
Diagram of Manifold Connections:
The manifold features clearly labeled ports for High Side (Red), Low Side (Blue), Evacuation, and Charging. It also includes calibration screws and hand valves for both high and low sides.
Operating Instructions:
1. TO PURGE HOSES WITH REFRIGERANT GAS.
- Connect hoses as shown with all valves closed on the MANIFOLD.
- Loosely connect hoses 1 & 2 to COMPRESSOR & service ports respectively.
- Open A & B valves on MANIFOLD.
- Open the valve on the refrigerant tank.
- Slowly open valve on MANIFOLD until gas escapes from H & service valve connections.
- Tighten the H & H hose nuts on & service valve connections.
2. TO CHARGE SYSTEM WITH VAPOR ON SUCTION SIDE
- Connect hoses as shown with all valves closed on the MANIFOLD.
- Purge hoses as in step 1.
- Open REFRIGERANT tank valve.
- Open valve on MANIFOLD.
- Open valve on A MANIFOLD.
- Open valve on MANIFOLD.
3. TO MONITOR SYSTEM PRESSURES
CONNECTIONS
- Connect hoses as shown with all valves closed on the MANIFOLD.
- Open & H service valves on COMPRESSOR.
4. TO EVACUATE SYSTEM
- Connect hoses as shown with all valves closed on the MANIFOLD.
- Start VACUUM pump.
- Open valve on MANIFOLD.
- Open A & B valves on MANIFOLD.
- Open & H service valves on COMPRESSOR.
Section D: Warranty
WARRANTY COVERAGE
This warranty applies to all orders, purchases, or use of products sold only by VIVOHOME and is valid for 1 year from the purchase date. This warranty only covers the original order. If a replacement is provided within the warranty period, it does not extend the warranty.
WARRANTY EXCLUSIONS
This warranty does not cover damages caused by misuse, accidents, unauthorized modifications, or any factors unrelated to product manufacturing and design, including but not limited to:
- Loss of parts during use.
- Normal wear and tear of products or parts.
- Incorrect installation (e.g., using the wrong voltage) or improper assembly.
- Overloading the product's bearing capacity.
- Usage in extremely harsh conditions.
- Improper cleaning or lack of maintenance.
- Damage resulting from unintended use of the product.
- Damage resulting from unauthorized modifications or service.
- Indirect losses or damages related to the product.
HOW TO MAKE A WARRANTY CLAIM
If you encounter any defects affecting the product's functionality or if the product fails and cannot be repaired during the warranty period, please reach out to VIVOHOME customer service team via email, or their app's messaging service at your earliest convenience. To expedite your claim, kindly include:
- Order number
- Photos and/or videos illustrating the issue
- A detailed description of the problem
VIVOHOME will provide technical support, replacement, refund, or other solutions based on the issue's specifics. If you wish to return the original package for any reason, please contact VIVOHOME for confirmation before initiating the return. You can expect a response within 48 hours.
Thank you for choosing VIVOHOME. We are dedicated to ensuring your satisfaction and the quality of your purchase. If you have any questions or need further assistance, please don't hesitate to reach out to our customer service team.