Grundfos LiqTec, 200-240 V

Installation and Operating Instructions

Introduction

The Grundfos LiqTec is designed to protect pumps from dry run conditions and excessive liquid temperatures. It offers robust construction and reliable operation.

Table of Contents

1. Description

The LiqTec unit provides protection for pumps by:

  • Protecting the pump from dry run conditions.
  • Protecting the pump from excessive liquid temperatures (up to 130 °C ± 5 °C).
  • Monitoring motor temperature when a PTC sensor is connected to the motor.
  • Featuring a fault-tolerant design. In case of a fault in the sensor, sensor cable, electronic module, or power supply, the pump is immediately shut down.

2. LiqTec Sensor Mounting

The LiqTec can be mounted on a DIN rail and installed in a control cabinet. Refer to page 4 for mounting illustrations.

3. Electrical Connection

Examples of electrical wiring are shown on page 5.

4. Sensor and LiqTec Calibration

Refer to the procedure described on the following page.

5. Functions

Diagram of LiqTec Unit and Connections:

Illustration shows the LiqTec unit with numbered connection terminals and indicator lights.

  • 1. Dry Run Sensor Connection: Dry run sensor product number: 96556427.
  • 2. External Start Connection: For external start signal.
  • 3. Motor PTC Indicator: A green light indicates normal operation or that PTC protection is not used (contacts are short-circuited). A red light indicates excessive motor temperature, triggering the signaling relay.
  • 4. PTC Sensor Connection: For connecting a PTC sensor compliant with DIN 44082 standard. If the PTC sensor is not used, the contacts must be short-circuited.
  • 5. Sensor Indicator Light: A red light indicates a damaged sensor or cable. Triggers the signaling relay.
  • 6. Dry Run Monitoring Function Disable: Pressing this button disables the dry run monitoring function. The red light will flash. PTC monitoring continues to function. Press the Restart button to re-enable the dry run monitoring function.
  • 7. High Liquid Temperature Indicator Light: A red light indicates that the liquid temperature is too high (130 °C ± 5 °C). Triggers the signaling relay.
  • 8. Power Supply: 200-240 V, 50/60 Hz.
  • 9. Dry Run Indicator Light: A green light indicates normal operation (liquid is present in the pump). A red light signals dry run (no liquid in the pump). Triggers the signaling relay.
  • 10. Alarm/Operation Relay Output: Zero-potential changeover contact. Maximum contact load: 250 V, 1 A, AC (inductive load).
  • 11. Auto/Man: Switch between automatic and manual restart. The default setting is Man (manual). Can be switched with a small screwdriver. When set to Auto, the alarm is automatically interrupted after 10-20 seconds of detecting liquid.
  • 12. Restart: Press this button to restart the pump if necessary. This button does not affect PTC monitoring.

6. Sensor and LiqTec Calibration Process

Step Action Result
1 Verify that the sensor is properly connected to the LiqTec (see page 5).
2 Before inserting the sensor into the pump, immerse it in standing water. Any container with water can be used. Note: It is important that the water is standing, as flowing water cooling the sensor will lead to inaccurate calibration.
3 Press and hold buttons 6 and 12 for approximately 20 seconds. All red indicator lights (except 7) will start flashing.
4 When green indicator lights 3 and 9 start to light up continuously, release buttons 6 and 12. Calibration is complete.

7. Additional Information

Information related to IEC 60730-1:

  • Software class A.
  • Degree of pollution 2.
  • Type 1.

LiqTec has been cURus approved according to UL 508.

Maximum pressure: 40 bar
Maximum liquid temperature: +130 °C ± 5 °C
Maximum ambient temperature: +55 °C
Power consumption: 5 Watt
Enclosure class: IPX0
Maximum cable length: 20 meters
Standard cable: 5 meters
Extension cable: 15 meters
Product number: 96443676

Wiring Diagram

Illustration shows a schematic wiring diagram connecting the LiqTec unit to power supply (L1, L2, L3, N), a sensor, an external restart input, a PTC sensor, and a motor (M) via a contactor (K1).

Key Connections:

  • Power input: L1, L2, L3, N (200-240 V).
  • Sensor input: Connects to the dry run sensor.
  • External restart: Input for an external restart signal.
  • PTC input: For connecting a motor PTC sensor.
  • Output: Controls a contactor (K1) which in turn controls the motor (M).

8. Waste Disposal

This product and its components must be disposed of in accordance with environmental regulations:

  1. Utilize the services of a public or private waste collection company.
  2. If this is not possible, contact Grundfos or an authorized Grundfos service workshop.

Subject to change.

Declaration of Conformity

The Grundfos LiqTec unit complies with relevant EC/EU directives. Declarations of conformity are available in multiple languages, including English and Lithuanian, and can be found in the product documentation. For the latest online version and full documentation, visit the Grundfos Product Center at: http://net.grundfos.com/qr/i/96562445

PDF preview unavailable. Download the PDF instead.

Grundfosliterature-3932609 17034799 FrameMaker 10.0.2 Acrobat Distiller 10.1.13 (Windows)

Related Documents

Preview Grundfos SQ/SQE Data Book: Features, Applications, and Technical Specifications
Comprehensive data book for Grundfos SQ/SQE submersible pumps, detailing features, benefits, applications, communication systems (CU300, R100), performance data, technical specifications, dimensions, weights, and materials of construction.
Preview Grundfos MS, MMS Submersible Motors: Installation and Operating Instructions
Comprehensive installation and operating instructions for Grundfos MS and MMS submersible motors, covering delivery, storage, general description, preparation, electrical connection, installation, maintenance, fault finding, and cable sizing.
Preview Grundfos IO 113 Installation and Operating Instructions
This document provides installation and operating instructions for the Grundfos IO 113, a device that interfaces between Grundfos wastewater pumps and pump controllers. It covers product description, intended use, user interface, indicator lights, identification, approvals, variants, expansion with SM 113, control functions, fault finding, alarms, warnings, calibration, maintenance, and disposal.
Preview Grundfos SQF Submersible Pump: Installation and Operating Guide
Comprehensive installation and operating instructions for the Grundfos SQF submersible pump range, detailing setup, operation, maintenance, and troubleshooting for professional installers and users.
Preview Grundfos MGE 71, MGE 80, MGE 90 Installation and Operating Instructions
Comprehensive guide for installing and operating Grundfos MGE 71, MGE 80, and MGE 90 frequency-controlled permanent-magnet motors. Covers electrical installation, user interfaces, technical data, safety, and maintenance.
Preview Grundfos MG Electric Motors: Installation and Operating Instructions
Comprehensive guide for the installation, operation, and maintenance of Grundfos MG series electric motors. Covers technical specifications, safety precautions, electrical and mechanical installation, troubleshooting, and disposal.
Preview Grundfos MG Motors: Installation and Operating Instructions
Comprehensive guide for the installation, operation, and maintenance of Grundfos MG series electric motors, covering technical specifications, safety, and troubleshooting.
Preview Grundfos UPM3(K) AUTO Circulation Pump - Installation and Operation Instructions
Comprehensive instructions for the Grundfos UPM3(K) AUTO high-efficiency circulation pump, covering installation, operation, technical specifications, and safety guidelines.