QDD-ZR-400G TEST REPORT (Cisco)

[ISO 9001 Certified][REACH Compliant][RoHS Compliant][CE Marked][FCC Certified]

1. Test Purpose

The test object is the QDD-ZR-400G Transceiver. Testing the module provides a foundation for subsequent cooperation with customers.

2. Test Results Summary

1st ItemsTest DataRemarks
Product Software Performance TestingPass
Product Compatibility TestingPass

3. Test Environment

3.1 Test Equipment Used

VendorDeviceSoft VersionHardware Version
FSCoding Board
CiscoNexus9000 C9332D-GX2B10.4(2)

3.2 Test Sample

Product IDP/NSerial Number
#193134QDD-ZR-400GA2310220131

4. Test Data

4.1 Product Software Performance Testing

Test Topology: A PC is connected to an FS Coding board, which is then connected to the QDD-400G ZR transceiver.

Test Scenario: The test setup involves a rack of networking equipment, including the FS Coding board and the transceiver, for performance evaluation.

Test Premise

1. The equipment can be powered up and run normally.

2. A test environment is built according to the networking described.

Test Equipment

Device: QDD-ZR-400G

Model No.: A2310220131

Test Method

1. The FS Coding board can read the P/N, serial number, optic type, and vendor name of the transceiver.

2. The transceiver is successfully coded by the FS Coding board.

3. With the FS Coding board and PC powered on, the optics are plugged and unplugged at least five times, and the read information is checked for consistency.

ItemsTest MethodContentThe Results
FunctionAccessible PagePass
CodingPass
UpgradeFirmware Online UpgradePass
StabilityHot SwapPass

Test Conclusion

After testing, the results of all tested items meet the requirements of the inspection basis.

Remarks

4.2 Product Compatibility Testing

Test Topology: A Switch is connected via a QSFP-DD-400G transceiver to a DWDM MUX DEMUX. A loopback connection is also present.

Test Equipment

Device: Cisco Nexus9000 C9332D-GX2B

Model No.: Nexus9000 C9332D-GX2B

Test Method

1. Check if the optics DDM threshold is accurate.

2. Check if DDM parameters, basic optics information, device port information, and device log information are normal.

Test Information

Software

Operating System: Cisco Nexus Operating System (NX-OS) Software

TAC Support: http://www.cisco.com/tac

Copyright: © 2002-2023, Cisco and/or its affiliates.

Software Licenses: Mentions GNU General Public License (GPL) versions 2.0/3.0 and GNU Lesser General Public License (LGPL) versions 2.1/2.0. Links provided for license details: gpl-2.0.php, gpl-3.0.html, lgpl-2.1.php, library.txt.

BIOS Version: 01.11

NXOS Version: 10.4(2) [Feature Release]

Host NXOS Version: 10.4(2)

BIOS Compile Time: 06/30/2023

NXOS Image File: bootflash:///nxos64-cs.10.4.2.F.bin

NXOS Compile Time: 11/30/2023 12:00:00 [12/14/2023 05:25:50]

NXOS Boot Mode: LXC

Hardware

Chassis: Cisco Nexus 9000 C9332D-GX2B Chassis

CPU: Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32801496 kB of memory.

Processor Board ID: FDO26450X3Y

Device Name: n

Kernel Uptime: 0 days, 0 hours, 43 minutes, 48 seconds

Last Reset Reason: Reset due to upgrade

System Version: 10.4(3)

Service: Core Plugin, Ethernet Plugin

Inventory

Chassis: NAME: "Chassis", DESCR: "Nexus9000 C9332D-GX2B Chassis", PID: N9K-C9332D-GX2B, VID: V01, SN: FDO26450X3Y

Slot 1: NAME: "Slot 1", DESCR: "32x400G QSFP-DD + 2x10G SFP+ Ethernet Module", PID: N9K-C9332D-GX2B, VID: V01, SN: FDO26450X3Y

Slot 27: NAME: "Slot 27", DESCR: "32x400G QSFP-DD + 2x10G SFP+ Ethernet Module", PID: N9K-C9332D-GX2B, VID: V01, SN: FDO26450X3Y

Power Supply 1: NAME: "Power Supply 1", DESCR: "Nexus9000 C9332D-GX2B Chassis Power Supply", PID: NXA-PAC-1500W-PI, VID: V01, SN: POG2646FTDA

Power Supply 2: NAME: "Power Supply 2", DESCR: "Nexus9000 C9332D-GX2B Chassis Power Supply", PID: NXA-PAC-1500W-PI, VID: V01, SN: POG2646FT6T

Fan 1: NAME: "Fan 1", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Fan 2: NAME: "Fan 2", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Fan 3: NAME: "Fan 3", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Fan 4: NAME: "Fan 4", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Fan 5: NAME: "Fan 5", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Fan 6: NAME: "Fan 6", DESCR: "Nexus9000 C9332D-GX2B Chassis Fan Module", PID: NXA-SFAN-35CFM-PI, VID: V01, SN: N/A

Interface Configuration (Ethernet 1/1)

zr-optics fec cFEC muxponder 1x400 modulation 16QAM dac-rate 1x1

zr-optics cd-min -2300 cd-max 2300

zr-optics transmit-power-70

zr-optics dwdm-carrier 100MHz-grid frequency 1921000

no shutdown

Interface Status
PortNameStatusVlanDuplexSpeedType
mgmt0notconnecroutedautoauto
Eth1/1connected1full400GQSFP-DD-400G-ZR-S
Interface Transceiver Details (Ethernet 1/1)

Transceiver is present.

Type: QSFP-DD-400G-ZR-S

Name: FS

Part Number: QDD-ZR-400G

Revision: A

Serial Number: A2310220126

Nominal Bitrate: 425000 MBit/sec per channel

Cisco ID: 24

Cisco Extended ID Number: 21

Firmware Version: 2.11

Link Length SMF: 8 km

Nominal Transmitter Wavelength: 1547.70 nm

Wavelength Tolerance: 0.015 nm

Host Lane Count: 8

Module Parameters

Media Lane Count: 1

Max Module Temperature: 70 deg C

Min Module Temperature: 0 deg C

Min Operational Voltage: 3.14 V

Vendor OUI: 0x7cb25c

Date Code: 240507

CLEI Code: INUIANYEAA

Power Class: 8 (>14 W maximum)

Max Power: 23.75 W

Near-end Lanes Used: none

Far-end Lane Code for 8 lanes: Undefined

Media Interface: unknown value 0x10

Advertising Code: Optical Interfaces: SMF

Host Electrical Interface Code: 400GAUI-8 C2M (Annex 120E)

FEC State

FEC State: FEC CFEC

Optics Status

Optics Type: QSFP-DD-400G-ZR-S

DWDM Carrier Info: Frequency: 192.10 THz

Alarm Status

DAC Rate: 1x1

Threshold Values

Configured Tx Power: 0 dBm

Modulation Type: 16QAM

Muxponder Type: 1x400

Configured CD-MIN: -1430864206 ps/nm

Configured CD-MAX: 530644985 ps/nm

Lane Data (Lane Number: 1 Network Lane)
MeasurementHighLowHighLow
AlarmAlarmWarningWarning
Temperature75.00 C0.00 C70.00 C0.00 C
Voltage3.60 V3.00 V3.46 V3.13 V
CurrentN/AN/AN/AN/A
Tx Power2.99 dBm-8.01 dBm1.99 dBm-7.01 dBm
Rx Power7.99 dBm-23.01 dBm7.99 dBm-22.21 dBm
Transmit Fault Count0

Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

*** This QSFP support partial diagnostic data! ***

Test Conclusion

The QDD-ZR-400G module was used in the test. After testing, the test results of the tested items (product software performance) meet the requirements of the test basis.

Remarks

5. Appendix

5.1 Product Software Performance Standards

Test ItemsContentStandards
FunctionAccessible PageThe model No., serial number, optics type, vendor name and other information of optics can be read.
UpgradeFirmware Online UpgradeOptics can be coded through BOX successfully
ReliabilityHot SwapWhen FS BOX and PC are powered on, plug and unplug the optics for at least five times, then check whether the read information are consistent.

5.2 Product Software Performance Standards

On the basis of threshold value range, the allowable deviation value should be within the standard range that is specified by FS.

ContentDetailsStandards
Basic InformationModel nameThe read model No. is consistent with the model of optics. (If there are special requirements, the actual information shall prevail)
SN NumberThe read serial number is consistent with the serial number on label of optics. (If there are special requirements, the actual information shall prevail)
Vendor NameThe vendor name information read is FS/OEM. (If there are special requirements, the actual information shall prevail)
TypeThe optics type information read by the switch is consistent with the actual optics model. (If there are special requirements, the actual information shall prevail)
DDM InformationTemperature1. The actual DDM information is within the DDM threshold and there is no alarm;
2. The DDM threshold range meets the product specification requirements.
Voltage
Bias current
Tx Power
Rx Power
Port InformationPort RateThe data rate information read on switch port is consistent with the actual rate of the optics
Port StatusAfter the product is connected, the port status information is UP
Switch Indicator StatusAfter the product is connected, the port indicators at both ends of the product will be green/orange
Switch LogExcept for the official certification warning information, no other warning information

PDF preview unavailable. Download the PDF instead.

qdd-zr-400g-test-report-cisco

Related Documents

Preview FS SFP-10G-T-30 Transceiver Test Report for Cisco Compatibility
This document presents the comprehensive test results for the FS SFP-10G-T-30 transceiver, verifying its performance and compatibility with Cisco networking environments. It covers test purpose, equipment used, test scenarios, and detailed results.
Preview FS SFP-10G-T-100 Transceiver Test Report for Cisco Compatibility
Comprehensive test report for the FS SFP-10G-T-100 transceiver, detailing its performance and compatibility with Cisco networking equipment, including test scenarios, equipment, and results.
Preview FS 40GBASE-SR4 QSFP+ 850nm 150m MTP/MPO Transceiver Datasheet
Datasheet for the FS 40GBASE-SR4 QSFP+ transceiver module, detailing its specifications, features, electrical and optical characteristics, pin descriptions, mechanical dimensions, and testing procedures for high-speed networking applications.
Preview FS QSFP-SR4-40G Transceiver Test Report: Cisco Compatibility and Performance
A comprehensive test report by FS detailing the performance, compatibility, and Digital Diagnostic Monitoring (DDM) of the QSFP-SR4-40G optical transceiver module with Cisco networking equipment, including test setup, results, and equipment specifications. Features ISO, REACH, CE, FCC, US, CB certifications.
Preview FS QSFP-LR4-40G Transceiver Test Report for Juniper Compatibility
This report details the comprehensive testing and validation of the FS QSFP-LR4-40G transceiver module, confirming its performance and interoperability with Juniper network devices. It covers test purpose, methodology, equipment, and detailed results including DDM information.
Preview SFP-10G-PCxxx Transceiver Test Report for Cisco Compatibility
This report details the test results for the FS SFP-10G-PCxxx transceiver, verifying its performance and compatibility with Cisco equipment, including detailed test scenarios, equipment used, and specific port status.
Preview FS SFP1G-ELX-31 Transceiver Test Report for Cisco Compatibility
This test report details the performance and compatibility testing of the FS SFP1G-ELX-31 SFP transceiver module with Cisco networking equipment, covering test purpose, methodology, and results.
Preview SFP-10GSR-85 Transceiver Test Report (Cisco Compatible)
Detailed test report for the FS SFP-10GSR-85 10GBASE-SR transceiver module, including test purpose, equipment used, test scenarios, results, and Digital Diagnostic Monitoring (DDM) data. Verified for compatibility with Cisco equipment.