Model: RCC60RVRE
Voltage: 12V/24V/36V/48V
Current: 60A
Version: A0
Date: June 4, 2024
Document Type: User Manual
This user manual provides essential operation and maintenance instructions for the Renogy 12V/24V/36V/48V 60A Solar MPPT Charge Controller. Please read it carefully before operation and save it for future reference. Failure to follow instructions may result in electrical shock, serious injury, death, or damage to the charge controller.
Renogy 12V/24V/36V/48V 60A Solar MPPT Charge Controller User Manual © 2024 Renogy. All rights reserved.
RENOGY and [Renogy Logo] are registered trademarks of Renogy.
For the online manual, please refer to the provided QR code [QR Code for Online Manual].
The following symbols highlight important information:
Icon | Name | Description |
---|---|---|
⚡️ | High Voltage | High voltage device. Installation should be performed by an electrician. |
? | High Temperature | This device will produce heat. Mount device away from other items. |
? | Environmental Hazard | Electronic Equipment. Do not put in landfill. |
✂️ | Wire Cutter | A wire cutter is needed for cutting and stripping wires prior to connection. |
? | Multi-meter | A multimeter is needed for testing equipment and verifying polarity of cables. |
? | Anti-static Glove | Anti-static gloves are recommended to prevent controller damage caused by static electricity. |
? | Electrical Tape | Electrical tape is recommended to safely insulate spliced or bare wires. |
? | Screwdriver | A common size screwdriver is needed to attach wires to the controller. |
Solar Input Current | 5A | 10A | 20A | 30A | 40A | 60A |
---|---|---|---|---|---|---|
Wire Cross Section Area (mm²) | 1.5 | 2.5 | 5 | 8 | 10 | 12 |
Wire AWG | 15 | 13 | 10 | 8 | 7 | 6 |
Thank you for choosing Renogy. This MPPT solar charge controller is designed for solar charge regulation and direct current output load control, primarily used in small to medium-sized off-grid solar power systems.
The charge controller features the following components:
Follow these steps for proper installation:
During installation, follow this connection order precisely:
Wiring Diagram Description: The diagram illustrates the connections between the solar panel(s) (via fuse), battery (via ANL fuse), DC load, and the Renogy BT-2 Bluetooth module. Color coding indicates positive (red) and negative (black) connections.
The charge controller can be connected to the DC Home app for remote monitoring and parameter adjustment using a Renogy BT-2 Bluetooth Module. For long-range communication and programming, connect the charge controller to Renogy ONE (sold separately) via Bluetooth, and then connect Renogy ONE to the DC Home app via Wi-Fi.
Short-Range Monitoring:
Wireless Long-Range Monitoring:
Recommended Components: Renogy BT-2 Bluetooth Module, Renogy ONE Core. Components marked with '*' are available on renogy.com.
Important Notes for Monitoring:
The LCD screen displays Active Functions, Charge Mode & Parameter, and Charge Status. Icons represent solar charging, battery status, and load status.
Status Icon | Indication | Status | Description |
---|---|---|---|
[Solar Charge Icon] | Solar Charge Indication | Flowing | Solar Power Charging Battery |
Off | Solar Power Not Charging Battery | ||
[DC Load Icon] | DC Load Indication | Flowing | DC Load Drawing Power |
Off | DC Load Off | ||
MPPT BOOST FLOAT |
Charge Mode | Steady On | MPPT Charge Mode / Boost Charge Mode / Float Charge Mode |
Off | Not Charging | ||
CHG-V | Voltage Setting | On | Setting Charge Voltage |
Off | Charge Voltage Has Been Set | ||
LDV-V | Over Discharge Volt Settings | On | Setting Charge Voltage |
Off | Charge Voltage Has Been Set | ||
[Solar Icon] | Solar Icon | Steady On | Daylight Detected |
Off | No Daylight Detected | ||
Flash | Solar System Over Voltage | ||
[Battery Icon] | Battery Icon | Steady On | Battery Connected and Functional |
Off | No Battery Connection | ||
Flash | Battery Over-Discharged | ||
[Load Icon] | Load Status | On | Load On |
Off | Load Off | ||
Flash | DC Load Short Circuit or Over-Load |
System Mode | Function Key | Input | Input Function |
---|---|---|---|
View Mode | ⬆️ | Short Press | View the previous page. |
⬇️ | Short Press | View the next page. | |
? | Short Press | DC Load On/Off (Only applicable when Load Mode is set to "15". See Load Mode Settings.) | |
Set Mode | ⚙️ | Long Press | Enter Setting Mode. |
⬆️ | Short Press | Increase the parameter value. | |
⬇️ | Short Press | Decrease the parameter value. | |
? | Short Press | Exit Setting Mode without saving. | |
⚙️ | Long Press | Save the settings and exit the Setting Mode. | |
Short Press | Jump to next parameter settings. |
The pre-startup display cycle occurs when the MPPT controller is powered on, typically lasting several seconds, during which the controller assesses the operating environment.
LCD Screen Display Cycle:
The battery voltage view is displayed by default. Use the ⬆️ and ⬇️ keys to cycle through views. The battery voltage view resumes after 30 seconds of inactivity. Error codes are displayed when an error is detected. The backlight stays on for 20 seconds with any button operation.
Navigation Flow:
To enter Setting mode, press the ⚙️ key on any view page other than Load Mode or Controller Temperature. Use the ⬆️ and ⬇️ arrow keys to select the battery mode, then long press ⚙️ to save.
Abbreviations | Battery Types | Description |
---|---|---|
FLd | Flooded Battery | Auto-recognition with default parameters set for each type of batteries. |
SEL | Sealed/AGM Battery | |
GEL | Gel Battery | |
LI | Lithium Battery (Lithium battery activation disabled) | Low temperature protection (Frozen charge forbid). Some parameters can be customized. |
ALI | Lithium Battery (Lithium battery activation enabled) | Low temperature protection (Frozen charge forbid). Some parameters can be customized. |
USE | Advanced User Mode | Most parameters can be customized. |
Pressing ⚙️ enters Setting mode. Choose LI, ALI, or USE mode. Short press ⚙️ again to cycle through parameters. Use ⬆️ and ⬇️ to adjust values, then long press ⚙️ to save.
Low Tem Protect Range: 32±9°F (0±5°C) or 5±9°F (-15±5°C). Protection automatically turns on/off after 30 seconds when temperature reaches the protected range.
Allows customization of most parameters, including System Voltage, Charge Voltage, Over-discharge Voltage, Over-discharge Recovery, Equalize Charge Voltage, Equalize Charge Interval, Boost Charge Voltage, Float Charge Voltage.
Enter Load Setting Mode by pressing ⚙️ in Load Mode view. Use ⬆️ and ⬇️ to cycle through modes. Long press ⚙️ to save and exit; short press ? to exit without saving.
Mode | Definition | Description |
---|---|---|
0 | Daylight Auto-Control | DC load turns on when no daylight is detected. |
1 to 14 | Daylight On / Timer Off | DC load turns on when no daylight is detected. DC load turns off according to timer. |
15 | Manual Mode | DC load turns on/off by pressing ?. |
16 | Testing Mode | DC load turns on and off in a quick succession. |
17 | Always On | DC load stays on. |
In the temperature display interface, long press ⚙️ to enter unit setting mode. Use ⬆️ and ⬇️ to switch between °F (Fahrenheit) and °C (Celsius). Long press ⚙️ to save and exit; short press ? to exit without saving.
Code | Error | Description & Quick Troubleshoot |
---|---|---|
E00 | No Error | No action needed. |
E01 | Battery Over-discharged | Battery voltage is too low. DC load will be turned off until battery re-charges to recovery voltage. |
E02 | Battery Over-voltage | Battery voltage has exceeded controller limit. Check battery bank voltage for compatibility. |
E04 | Load Short Circuit | DC load short circuit. |
E05 | Load Overload | DC load power draw exceeds controller capability. Reduce load size or upgrade controller. |
E06 | Overheating | Controller exceeds operating temperature limit. Ensure controller is in a well-ventilated, cool, dry place. |
E07 | Environmental Overtemperature | Environment temperature sampled by external probe is too high. |
E10 | Solar Over-voltage | Solar array voltage exceeds controller rated input voltage. Decrease solar panel voltage. |
E13 | Solar Reverse Polarity | Solar input wires connected with reverse polarities. Disconnect and re-connect correctly. |
E14 | Battery Reverse Polarity | Battery connection wires connected with reverse polarity. Disconnect and re-connect correctly. |
For further assistance, contact Renogy technical support: ? renogy.com/contact-us.
The variable "n" is a multiplying factor for parameter voltages based on battery system voltage (12V: n=1; 24V: n=2; 36V: n=3; 48V: n=4). Example: Equalize charge voltage for 12V FLD is 14.8V*1=14.8V; for 24V FLD is 14.8V*2=29.6V.
Parameters | Battery Type | USE (Recommended Range) | ||||
---|---|---|---|---|---|---|
SLD/AGM | GEL | FLD | LI/ALI | USE (Default) | ||
Overvoltage Shutdown | 16.0V *n | 16.0V *n | 16.0V *n | 16.0V *n | 16.0V *n | 9V to 17V *n |
Overvoltage Reconnect | 15.0V *n | 15.0V *n | 15.0V *n | 15.0V *n | N/A | N/A |
Equalization Voltage | 14.6V *n | N/A | 14.8V *n | N/A | N/A | 9V to 17V *n |
Boost Voltage | 14.4V *n | 14.4V *n | 14.2V *n | 14.6V *n (Range: 9V to 17V) | 14.2V *n | 9V to 17V *n |
Boost Return Voltage | 14.0V *n | 13.8V *n | 14.2V *n | 14.0V *n | 13.8V *n | 9V to 17V *n |
Float Voltage | 13.8V *n | 13.8V *n | 13.8V *n | N/A | 13.8V *n | 9V to 17V *n |
Undervoltage Warning | 12.0V *n | 12.0V *n | 12.0V *n | 12.0V *n | 12.0V *n | 9V to 17V *n |
Undervoltage Alarm Recovery | 12.2V *n | 12.2V *n | 12.2V *n | 12.2V *n | 12.2V *n | 9V to 17V *n |
Low Voltage Warning | 11.0V *n | 11.0V *n | 11.0V *n | 11.0V *n | 11.0V *n | 9V to 17V *n |
Low Voltage Alarm Recovery | 12.6V *n | 12.6V *n | 12.6V *n | 12.6V *n | 12.6V *n | 9V to 17V *n |
Equalization Interval | 30 days | N/A | 30 days | N/A | N/A | 0 to 250 days (0 represents equalization charged disabled) |
Equalization Duration | 120 min | N/A | 120 min | N/A | N/A | 10 to 600 min |
Boost Duration | 120 min | 120 min | 120 min | N/A | 120 min | 10 to 600 min |
To enable lithium battery activation, set the battery type to ALI. When the connected lithium battery voltage is 0V, the activation function triggers automatically. The controller activates the battery at a constant voltage of 14.4V (12V systems), 28.8V (24V systems), 43.2V (36V systems), or 57.6V (48V systems).
After constant charging, the LCD will display "AALI". Activation is successful when charging current exceeds 300mA, and the controller exits activation mode.
Model | RCC60RVRE |
System Wiring Grounded | Negative Grounded |
Battery System Voltage | 12V/24V/36V/48V (Auto: FLD/GEL/SEL/USE; Manual: LI/USE) |
No-load Loss | 12V: 15mA, 24V: 11mA, 36V: 8mA, 48V: 7mA |
Max Solar Input Voltage (Voc) | < 150V |
Rated Solar Charge Current | 60A |
Max Solar Input Power | 12V: 900W, 24V: 1800W, 36V: 2600W, 48V: 3200W |
Light Control Voltage | 5V*n |
Light Control Delay Time | 5mins |
Rated Load Current | 20A |
Operating Temperature | -31°F to 113°F / -35°C to 45°C |
IP Protection | IP32 |
Net Weight | 7.72 lbs / 3.5 kg |
Communication Port | RS485 |
Operating Altitude | ≤ 3000 meters |
Dimension | 12 x 8.07 x 3.9 in / 305 × 205 × 99 mm |
The charge controller measures 12 inches (305 mm) in length, 8.07 inches (205 mm) in width, and 3.9 inches (99 mm) in height. Dimension tolerance is ±0.2 inches (0.5 mm).
For optimal performance, perform these tasks regularly:
Note on Corrosion: Corrosion can loosen terminals and increase resistance. Apply dielectric grease periodically to repel moisture and protect contacts.
⚡️⚠️ Risk of electric shock! Ensure all power supplies are turned off before touching terminals.
Follow these steps for regular cleaning:
To ensure proper storage:
To discuss inaccuracies or omissions, visit or contact us:
Explore solar systems at the Renogy Learning Center: ? renogy.com/learning-center
For technical questions in the U.S.:
For technical support outside the U.S., visit local websites:
Canada: ? ca.renogy.com | China: ? www.renogy.cn |
Australia: ? au.renogy.com | Japan: ? jp.renogy.com |
South Korea: ? kr.renogy.com | Germany: ? de.renogy.com |
United Kingdom: ? uk.renogy.com | Other Europe: ? eu.renogy.com |
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Renogy aims to empower people globally through education and distribution of DIY-friendly renewable energy solutions, driving sustainable living and energy independence. Their solar products help minimize carbon footprints by reducing reliance on grid power.
A 1 kW solar energy system can contribute significantly:
Renogy Power Plus keeps users updated on solar innovations, allows sharing of solar energy journeys, and connects them with a community making a difference. Connect via:
Renogy reserves the right to change manual contents without notice.
Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625, Taicang German Overseas Students Pioneer Park, JiangSu 215000 CN
EC Representative: eVatmaster Consulting GmbH, Battinastr.30, 60325 Frankfurt am Main, Germany (contact@evatmaster.com)
UK Representative: EVATOST CONSULTING LTD, Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR (contact@evatmaster.com)
Certifications: CE, FC, ROHS [Certifications Icons]
Website: ? RENOGY.COM
![]() |
Renogy Solar MPPT Charge Controller RCC60RVRE-G1 User Manual User manual for the Renogy 12V/24V/36V/48V 60A Solar MPPT Charge Controller (Model RCC60RVRE-G1). Covers features, installation, wiring, monitoring, LCD display, settings, error codes, specifications, and maintenance. |
![]() |
Renogy Rover 100A MPPT Solar Charge Controller Specifications Detailed specifications for the Renogy Rover 100A MPPT Solar Charge Controller, including features, technical data, and battery charging parameters for various battery types. |
![]() |
Renogy Off-Grid Solutions for RVs, Caravans, and Campers | Product Catalog Explore Renogy's comprehensive range of trusted off-grid power solutions, including solar panels, batteries, charge controllers, and inverters, designed for RVs, caravans, campers, and homes. Discover innovative technology for energy independence. |
![]() |
Renogy Rover Li Series MPPT Solar Charge Controller User Manual User manual for the Renogy Rover Li Series MPPT Solar Charge Controller, covering installation, operation, and maintenance for 12V/24V 20A/30A/40A off-grid solar systems. Features MPPT technology and comprehensive protection. |
![]() |
Renogy MPPT Tracer Series Solar Charge Controller Manual Comprehensive guide to Renogy's MPPT Tracer Series solar charge controllers (20A, 30A, 40A), covering safety instructions, installation, operation, troubleshooting, and technical specifications for off-grid solar applications. |
![]() |
Renogy Rover Series MPPT Charge Controllers: 20A, 30A, 40A User Manual User manual for Renogy Rover Series MPPT charge controllers (20A, 30A, 40A). Details safety, installation, operation, MPPT technology, and troubleshooting for off-grid solar systems. |
![]() |
Renogy Rover Series MPPT Charge Controller Manual This manual provides essential safety, installation, and operating instructions for the Renogy Rover Series MPPT Charge Controllers (20A, 30A, 40A). Learn about MPPT technology, charging stages, battery safety, and troubleshooting. |
![]() |
Renogy MT-5 Tracer Meter User Manual User manual for the Renogy MT-5 Tracer Meter, a remote digital display for MPPT Charge Controllers. Provides detailed information on installation, operation, data settings, system status, troubleshooting, and technical specifications. |