KSD(037) Series Single-Phase AC Output Solid State Relays

Product Description

The KSD(037) series comprises normally open single-phase AC solid-state relays designed for various control applications. These relays feature a control voltage range of 15~32VDC or 4~32VDC, and can handle load voltages of 240VAC, 380VAC, or 480VAC with a load current of 5A. They are suitable for applications such as lighting control, motor control, and solenoid valve operation.

Key Features:

  • Load Current: 5A
  • Control Voltage: 15~32VDC, 4~32VDC
  • Load Voltage: 240VAC, 380VAC, 480VAC
  • Dielectric Strength: 4000Vrms
  • Output Type: SCR Output
  • Compliance: RoHS Compliant
  • Circuitry: Built-in RC Absorption Circuit
  • Mounting: PCB mounting type

Product Selection

The model naming convention for the KSD(037) series is structured as follows: KSD [Load Voltage] [Triggering Type] [Load Current] [-Control Type] [(037)]

SeriesLoad VoltageTriggering TypeLoad CurrentControl TypeHousing Structure
KSD Series240: 240VAC
380: 380VAC
480: 480VAC
D: Zero Crossing
R: Random
5: 5 AmpH: 15~32VDC
W: 4~32VDC
(037): Standard housing

Optional Models:

Control TypeModel
H: 15~32VDCKSD240D5-H(037)
KSD380D5-H(037)
KSD480D5-H(037)
W: 4~32VDCKSD240D5-W(037)
KSD380D5-W(037)
KSD480D5-W(037)
H: 15~32VDCKSD240D5R-H(037)
KSD380D5R-H(037)
KSD480D5R-H(037)
W: 4~32VDCKSD240D5R-W(037)
KSD380D5R-W(037)
KSD480D5R-W(037)

Technical Parameters

Input Parameters (Ta=25°C)

ParameterControl TypeValue
Control Voltage RangeH15~32VDC
W4~32VDC
Pick-up VoltageH15VDC
W4VDC
Release VoltageH5VDC
W1VDC
Max Control CurrentH/W25mA (@32VDC)

Output Parameters (Ta=25°C)

ParameterLoad VoltageValue
Load Voltage Range240VAC24~280VAC
380VAC24~440VAC
480VAC24~530VAC
Max Transient Voltage240VAC600Vpk
380VAC800Vpk
480VAC1200Vpk
Load Current Range0.1~5A
Max Surge Current (@10ms)250A
Max Turn-on Time1ms
Max Turn-off Time1/2cycle+1ms
Max Off-state Leakage Current (@ Rated Voltage)5mA
Max On-state Voltage Drop (@ Rated Current)1.5Vrms
dv/dtRandom Type500V/µs
Zero Crossing Type500V/µs

Other Parameters (Ta=25°C)

ParameterValue
Dielectric Strength (50Hz/60Hz)4000Vrms
Insulation Resistance (@500VDC)>1000MΩ
Operating Temperature Range-30°C ~ +80°C
Storage Temperature Range-30°C ~ +100°C
Weight (Typical)20g

Application Scenarios

Suitable for lighting control, motor control, solenoid valves, and other similar applications.

Outline Dimensions

The external dimensions of the KSD(037) series relay are provided in the diagram. Key dimensions include:

  • Overall length: 44.5mm (max)
  • Overall width: 26mm (max)
  • Overall height: 10.5mm (max)
  • Mounting hole diameter: φ1 ±0.1mm
  • Pin pitch details are provided in the diagram.
Diagram shows a rectangular component with pins and mounting holes. Dimensions are labeled in millimeters.

Wiring Diagram

The wiring diagram illustrates the connections for the solid-state relay:

  • DC Input: Connect to DC- and DC+ terminals.
  • AC Output: Connect to AC~ and AC~ terminals.
Diagram shows a block with input terminals labeled DC- and DC+, and output terminals labeled AC~ and AC~. Internal circuitry includes protection components like diodes and an RC snubber.

Temperature Derating Curve

The graph shows the relationship between ambient temperature and the maximum allowable load current. As the ambient temperature increases, the maximum load current capacity decreases. For example, at 25°C, the current is 5A, but it derates significantly above 40°C.

Graph with Ambient Temperature (°C) on the x-axis and Load Current (A) on the y-axis. The curve starts at 5A at 25°C and slopes downwards, indicating current derating at higher temperatures.

Precautions

  • Soldering Temperature: Do not exceed 260°C for more than 10 seconds during soldering. At 350°C, the soldering time must not exceed 5 seconds, as this may damage the product.
  • Control Terminal Polarity: Ensure correct polarity for the control terminals; incorrect polarity can damage the product.
  • Ambient Temperature: If operating in a high ambient temperature environment, refer to the temperature derating curve for proper usage.

Safety Warnings

  • ⚠️ Warning: The side and bottom of the product may become hot during use. Allow it to cool before touching.
  • ⚠️ Warning: Ensure all power is disconnected before installing or using this product.
  • ⚠️ Warning: Check all connections are secure before applying power.

Certification Standards

Certification TypeTesting Standard
ULUL508
CEEN 60947-1:2007/A2:2014
EN 60947-4-3:2014
CCCGB/T14048.5-2017
CQCGB/T14048.5-2017

Version V5.0, 01-20-2025. Information subject to change without notice. For inquiries, please contact the company.

Copyright © 2025 KUDUN ELECTRONIC TECHNOLOGY (XIAMEN) CO., LTD. Website: www.i-autoc.com / www.i-autoc.cn

ISO 9001, ISO 14001, ISO 45001 Certified

PDF preview unavailable. Download the PDF instead.

686c083c0f0f5af1 Adobe PDF library 17.00 Adobe Illustrator 28.0 (Windows)

Related Documents

Preview i-Autoc KSH Series Single-Phase Solid-State Relays Datasheet
Comprehensive technical specifications, features, selection guide, and application information for i-Autoc KSH series single-phase solid-state relays (SSRs) with SCR output, rated for 25A and voltages up to 600VAC.
Preview i-Autoc KSHA Series Single-Phase Solid State Relays - Technical Specifications
Detailed technical specifications and product information for the i-Autoc KSHA series single-phase AC output solid-state relays, featuring SCR output, PCB mounting, and various voltage/current ratings.
Preview i-Autoc KSA Series Single-Phase AC Output Solid State Relays - Datasheet
Technical datasheet for i-Autoc KSA series single-phase AC output solid state relays. Features include DC control input, TRIAC output, high surge current, and various voltage options. View specifications, model selection, dimensions, and certifications.
Preview i-Autoc KSQF Series Three-Phase Solid State Relays: Specifications, Selection, and Applications
Detailed technical guide for i-Autoc KSQF series three-phase AC output solid state relays. Covers product features, model selection, input/output specifications, thermal management, wiring, dimensions, applications, and safety precautions.