i-Autoc KSHA Series Single-Phase AC Output Solid State Relays

Product Datasheet

Product Description

The KSHA series are single-phase solid-state relays featuring an internal SCR structure and PCB mounting. They are widely used in various industrial applications and are suitable for resistive, inductive, and capacitive loads. The relays support load voltages of 240VAC, 480VAC, and 600VAC, with an output current of 25A.

Key Features:

Product Selection

The KSHA series model naming convention is as follows:

Series Load Voltage Control Type Load Current Trigger Type Protection Customer Code
KSHA 240: 240VAC
480: 480VAC
600: 600VAC
D: DC Input 25: 25Amp (Blank): Zero-crossing
R: Random
(Blank): None
T: TVS Protection(1)
(XXX)

Example Model: KSHA480D25R-T

(1) 600VAC models do not include TVS protection.

Technical Parameters

Input Parameters (Ta=25°C)

Parameter Value
Control Voltage Range 4~32VDC
Must-ON Voltage 4VDC
Must-OFF Voltage 1VDC
Max Input Current 25mA @ 32VDC (Random)
18mA @ 32VDC (Zero-crossing)

Output Parameters (Ta=25°C)

Parameter Value
Load Voltage Range 24~280VAC (for 240VAC models)
24~530VAC (for 480VAC models)
24~660VAC (for 600VAC models)
Max ON-State Voltage Drop 1.5Vrms (@ rated current)
Max Surge Current (@10ms) 250A
Max Transient Voltage 600Vpk (for 240VAC models)
1200Vpk (for 480VAC/600VAC models)
Max OFF-State Leakage Current (@ rated voltage) 5mA
Min Rate of Voltage Rise (dv/dt) 500 V/µs

Available Models:

Other Parameters (Ta=25°C)

Parameter Value
Dielectric Strength (50Hz/60Hz) Input/Output: 4000VACrms
Input/Baseplate: 2500VACrms
Power Factor >0.5
Operating Temperature Range -30°C ~ +80°C
Storage Temperature Range -30°C ~ +100°C
Weight (Typical) 65g

Application Scenarios

Suitable for lighting control, food machinery, medical equipment, elevators, and electric control doors.

Outline Dimensions

The solid-state relay has a rectangular base with pins for mounting and connection. The main body dimensions are approximately 35mm in height, 17.8mm in width, and 63mm in depth. There are mounting provisions on the base. The pins are arranged linearly.

Pin Configuration:

Wiring Diagram

The wiring diagram shows the DC input connected to terminals 1 and 2, and the AC output connected to terminals 3 and 4 for the load.

Temperature Curve

The temperature curve illustrates the derating of load current based on ambient temperature. For example, at an ambient temperature of 50°C, the maximum continuous current is approximately 11.5A without forced air cooling. At higher temperatures, the allowable current decreases significantly. A note indicates that the heat sink temperature should not exceed 85°C when using forced air cooling.

Precautions

  1. When the ambient temperature is high or solid-state relays are mounted closely together, users should consider derating the current capacity based on the temperature curve.
  2. For multiple solid-state relays operating simultaneously, it is recommended to maintain a spacing of at least one product width between them.

Safety Warnings

  1. The sides and baseplate of the product can become hot during operation. Allow the unit to cool before touching.
  2. Before installing or using this product, ensure that all power sources are disconnected.
  3. Verify that all connections are secure and correct before applying power.

PDF preview unavailable. Download the PDF instead.

e981b5069f83cda7 Adobe PDF library 17.00 Adobe Illustrator 28.0 (Windows)

Related Documents

Preview i-Autoc KSH Series Single-Phase Solid-State Relays Datasheet
Comprehensive technical specifications, features, selection guide, and application information for i-Autoc KSH series single-phase solid-state relays (SSRs) with SCR output, rated for 25A and voltages up to 600VAC.
Preview KSD(037) Series Single-Phase AC Output Solid State Relays - i-Autoc
Detailed technical specifications and product information for the i-Autoc KSD(037) series single-phase AC output solid-state relays, covering features, model selection, technical parameters, dimensions, wiring, precautions, and certifications.
Preview i-Autoc KSQF Series Three-Phase Solid State Relays: Specifications, Selection, and Applications
Detailed technical guide for i-Autoc KSQF series three-phase AC output solid state relays. Covers product features, model selection, input/output specifications, thermal management, wiring, dimensions, applications, and safety precautions.
Preview i-Autoc KSA Series Single-Phase AC Output Solid State Relays - Datasheet
Technical datasheet for i-Autoc KSA series single-phase AC output solid state relays. Features include DC control input, TRIAC output, high surge current, and various voltage options. View specifications, model selection, dimensions, and certifications.