i-Autoc KSA Series Single-Phase AC Output Solid State Relays

Product Description

The KSA series comprises normally open, compact AC solid-state relays designed for controlling solenoid valves, motors, and similar loads. They feature DC control input and offer either current-driven (10mA) or voltage-driven (5VDC, 12VDC, 24VDC) control options. The relays provide photoelectric isolation between input and output, with output triggering available in AC zero-crossing or random modes.

Product Selection

The model number is structured as follows:

PartDescription
KSASeries
240Load Voltage (240VAC)
DDC Control Input
2Load Current (2A)
RTriggering Type (R = Random; default = Zero-Crossing)
5 / 12 / 24 / IControl Voltage (5VDC / 12VDC / 24VDC / 10mA)
TTerminal Type (T = T-type terminals; default = Standard Pins)

Available Models

Control VoltageZero-Crossing ModelsRandom Triggering Models
5VDCKSA240D2-5KSA240D2R-5
12VDCKSA240D2-12KSA240D2R-12
24VDCKSA240D2-24KSA240D2R-24
10mAKSA240D2-IKSA240D2R-I

Models with T-type terminals are indicated by adding 'T' to the model number (e.g., KSA240D2-5T).

Technical Parameters

Input Parameters (Ta=25°C)

ParameterValue
Control Voltage Range5: 4~6VDC, 12: 9.6~14.4VDC, 24: 19.2~28.8VDC
Control Current Range10mA~25mA
Pick-up Voltage5: 4VDC, 12: 9.6VDC, 24: 19.2VDC
Pick-up Current10mA
Release Voltage5/12/24: 1VDC
Release Current5/12/24: 1mA

Output Parameters (Ta=25°C)

ParameterValue
Load Voltage Range24~280VAC
Max. Surge Current (@10ms)35Apk
Max. I²t Value (@10ms)6.1A²s
Max. On-State Voltage Drop (@ Rated Load Current)1.5Vrms
Max. On-State Time1/2cycle+1ms
Max. Off-State Time1ms
Operating Frequency47~63Hz
Min. Power Factor0.5
Dielectric Strength (Input/Output, 50Hz/60Hz)2500Vrms
Insulation Resistance (@500VDC)1000MΩ
Operating Temperature Range-30°C to +80°C
Storage Temperature Range-30°C to +100°C
Weight (Typical)6g

Application

Suitable for controlling solenoid valves, motors, and other AC loads.

Outline Dimensions

The KSA series relays are available in standard pin and T-type terminal configurations. Dimensions are approximately 24.2mm (Length) x 6.7mm (Width) x 21.4mm (Height).

Standard Pin Configuration: Features pins with a 2.54mm pitch for PCB mounting.

T-type Terminal Configuration: Features T-shaped terminals for alternative connections.

Wiring Diagram

Standard Pin Layout:

T-type Terminal Layout:

Temperature Curve

The graph illustrates the derating of the load current based on ambient temperature. It shows that the maximum load current decreases as the ambient temperature increases above approximately 30°C.

Precautions

Safety Warnings

Certifications

Certification TypeTest StandardCertificate Number
ULUL508E471925
TÜVEN62314B 089797 0016

PDF preview unavailable. Download the PDF instead.

98f39f4b3ee1ff71 Adobe PDF library 17.00 Adobe Illustrator 28.0 (Windows)

Related Documents

Preview KSD(037) Series Single-Phase AC Output Solid State Relays - i-Autoc
Detailed technical specifications and product information for the i-Autoc KSD(037) series single-phase AC output solid-state relays, covering features, model selection, technical parameters, dimensions, wiring, precautions, and certifications.
Preview i-Autoc KSH Series Single-Phase Solid-State Relays Datasheet
Comprehensive technical specifications, features, selection guide, and application information for i-Autoc KSH series single-phase solid-state relays (SSRs) with SCR output, rated for 25A and voltages up to 600VAC.
Preview i-Autoc KSHA Series Single-Phase Solid State Relays - Technical Specifications
Detailed technical specifications and product information for the i-Autoc KSHA series single-phase AC output solid-state relays, featuring SCR output, PCB mounting, and various voltage/current ratings.
Preview i-Autoc KSQF Series Three-Phase Solid State Relays: Specifications, Selection, and Applications
Detailed technical guide for i-Autoc KSQF series three-phase AC output solid state relays. Covers product features, model selection, input/output specifications, thermal management, wiring, dimensions, applications, and safety precautions.