HIKVISION DS-KV8X13-WME1(C)

Video Intercom Villa Door Station

Quick Start Guide

1 Appearance

The door station features the following components:

Note: The debugging port is used for debugging only.

2 Terminal and Wiring Description

2.1 Terminal Description

The door station has various terminals for connection:

NameInterfaceDescription
DOORNC2Door Lock Relay Output 2 (NC)
COM2Common Interface
NO2Door Lock Relay Output 2 (NO)
GNDGrounding
NC1Door Lock Relay Output 1 (NC)
COM1Common Interface
NO1Door Lock Relay Output 1 (NO)
GNDGrounding
ALARM INAI1Alarm Input 1 (For the access of Door Contact)
AI2Alarm Input 2 (For the access of Door Contact)
AI3Alarm Input 3 (For the access of Exit Button)
AI4Alarm Input 4 (For the access of Exit Button)
RS-485485+RS-485 Interface (Reserved)
485-RS-485 Interface (Reserved)
Power Input12 VDC INPower Supply Input
GNDGrounding
NetworkLANNetwork Interface

Note: Before accessing to the Door Contact, select Input as Door Status in I/O Settings page first.

Note: Before accessing to the Exit Button, select Input as Exit Button in I/O Settings page first.

2.2 Wiring Description

2.2.1 Door Lock Wiring

The door station supports connection to door locks via relay outputs. Terminal NC1/COM1 is set as default for magnetic lock/electric bolt, while NO1/COM1 is for electric strike. For terminal NO2/COM2/NC2, configuration via iVMS-4200 client software is required for electric lock connection.

2.2.2 Door Contact Wiring

Connect the door contact sensor to the AI1 or AI2 terminals. The status of the door can be monitored.

2.2.3 Exit Button Wiring

Connect the exit button to the AI3 or AI4 terminals. Pressing the button allows exiting.

2.2.4 Alarm Input Device Wiring

Connect alarm input devices to the AI terminals for monitoring external alarms.

3 Installation Accessory

The following accessories are included for installation:

4 Installation

The video intercom villa door station supports surface mounting. Ensure all related equipment is power-off during installation. Tools required: Drill (ø2.846) and gradienter. A protective shield should be purchased before installation if needed.

Surface Mounting without Protective Shield

  1. Stick the mounting template on the wall and drill screw holes according to the template. Remove the template.
  2. Secure the mounting plate on the wall with 4 supplied screws.
  3. Secure the device on the mounting plate with 4 supplied set screws.
  4. Fix the cover onto the device with the screw.

Surface Mounting with Protective Shield

  1. Stick the mounting template on the wall and drill screw holes according to the template. Remove the template.
  2. Align the protective shield with the mounting template.
  3. Secure the mounting plate on the wall with 4 supplied screws.
  4. Secure the device on the mounting plate with 4 supplied set screws.
  5. Fix the cover onto the device with the screw.

Flush Mounting without Protective Shield

  1. Stick the mounting template on the wall. Drill the hole according to the mounting template. Remove the template. The suggested hole size is 169.4 mm x 86.2 mm x 33.5 mm.
  2. Install the gang box into the hole with 4 screws.
  3. Insert the device into the gang box and secure it with 4 supplied screws.
  4. Fix the cover onto the device with the screw.

Flush Mounting with Protective Shield

  1. Stick the mounting template on the wall. Drill the hole according to the mounting template. Remove the template. The suggested hole size is 169.4 mm x 86.2 mm x 33.5 mm.
  2. Install the gang box into the hole with 4 screws.
  3. Align the protective shield with the gang box.
  4. Insert the device into the gang box and secure it with 4 supplied screws.
  5. Fix the cover onto the device with the screw.

Recommended Installation Height

The recommended installation height for the camera is between 1.4 m and 1.6 m from the ground. This ensures optimal viewing angles, with a horizontal field of view of 124° and a vertical field of view of 75°. The highest point of the device can reach up to 1.98 m, while the lowest visible point is 1.02 m when mounted at the lower end of the recommended height range.

5 Configuration via Web

1 Activate Device via Web

The device requires activation with a strong password before use. Default parameters: IP Address: 192.0.0.65, Port: 8000, User Name: admin.

  1. Power on the device and connect it to the network.
  2. Enter the device's IP address into a web browser to access the activation page. (Note: The computer and device must be on the same subnet.)
  3. Create and enter a password.
  4. Confirm the password.
  5. Click OK to activate.

Note: Device activation is necessary for basic operation and remote configuration.

2 Access to the Device by Web Browsers

  1. Enter the device's IP address in the browser's address bar and press Enter to reach the login page.
  2. Enter the user name and password, then click Login.

3 Communicate with Indoor Station

  1. Navigate to Settings -> Intercom -> Press Button to Call.
  2. Set parameters, including call numbers for each button. The 'Call Management Center' option, if checked and configured, has higher priority than individual call numbers.
  3. Press the button to call the indoor station.

4 Issue Card

  1. Navigate to User settings and click Add -> Add Card.
  2. Present the M1 card on the card reading area.
  3. A confirmation window will appear upon successful card issuance.

Note: Only M1 cards are supported. Up to 10,000 cards can be managed. A voice prompt indicates when the limit is reached.

5 Unlock Door

After issuing cards, present an authorized card at the card reading area to unlock the door.

Refer to the Video Intercom Villa Door Station User Manual for more details.

Models: DS-KV8113, DS-KV8213, DS-KV8413-WME1 C, DS-KV8113 Video Intercom Villa Door Station, DS-KV8113, Video Intercom Villa Door Station, Intercom Villa Door Station, Villa Door Station, Door Station

PDF preview unavailable. Download the PDF instead.

S5cc4d7e5e24946debac8b6a7794ad1a1K PDFlib PDI 9.3.1-i (Win32) Serif Affinity Designer 1.10.1

Related Documents

Preview Hikvision DS-KV8X13-M Video Intercom Villa Door Station Quick Start Guide
This guide provides instructions for installing and configuring the Hikvision DS-KV8X13-M Video Intercom Villa Door Station. It covers product appearance, terminal connections, installation methods (surface and flush mounting), web activation, and basic operational steps.
Preview Hikvision Video Intercom System User Manual - DS-KV8X13-WME1(C) & DS-KH6320-WTE1
Comprehensive user manual for Hikvision DS-KV8X13-WME1(C) Villa Door Station and DS-KH6320-WTE1 Network Indoor Station, covering installation, configuration, terminal descriptions, wiring, product overview, and detailed specifications.
Preview HIKVISION DS-KV61X3-(W)PE1(C) Video Intercom Villa Door Station Quick Start Guide
Installation and configuration guide for the HIKVISION DS-KV61X3-(W)PE1(C) Video Intercom Villa Door Station. Covers appearance, terminal functions, wiring, installation methods (surface mounting), and web-based configuration for device activation, access, communication, and card management.
Preview Hikvision DS-KV8X13-M Video Intercom Villa Door Station Quick Start Guide
This document provides a quick start guide for the Hikvision DS-KV8X13-M Video Intercom Villa Door Station. It details appearance references, terminal descriptions, installation procedures (surface and flush mounting), and web configuration steps for activating the device, accessing it via web browser, communicating with indoor stations, issuing access cards, and unlocking doors.
Preview Hikvision IP & 2-Wire Video Intercom Systems: Design, Performance, and Solutions
Explore Hikvision's advanced IP and 2-wire video intercom systems, offering seamless integration, modular design, superior performance, and enhanced security for residential and commercial applications. Discover features like IoT convergence, remote access, and RedDot award-winning design.
Preview Hikvision DS-KV9503-WBE1 Villa Door Station Quick Start Guide
This guide provides essential information for installing and configuring the Hikvision DS-KV9503-WBE1 Villa Door Station, covering its appearance, terminal connections, mounting procedures, user management, and optimal installation heights.
Preview Hikvision HiWatch DS-D100IPF Villa Door Station Quick Start Guide
A quick start guide for the Hikvision HiWatch DS-D100IPF Villa Door Station, detailing its appearance, terminal connections, installation procedures, web configuration, communication with indoor stations, and card issuance for access control.
Preview Hikvision DS-D100IPF Video Intercom Villa Door Station Quick Start Guide
This guide provides essential information for installing and configuring the Hikvision DS-D100IPF Video Intercom Villa Door Station. Learn about its features, wiring, installation process, web activation, access control, and communication with indoor stations.