This user manual provides comprehensive information for operating the Microtech Computerized Height Gauge.
Certifications
Calibration: ISO 17025:2017
Quality Management: ISO 9001:2015
Specifications
FORCE COMPUTERIZED HEIGHT GAUGE
Item No | Range (mm) | Resolution (mm) | Accuracy (mm) | Force control (N) | Base | Functions | Data output (USB/Wireless) | Calibration (ISO 17025) |
---|---|---|---|---|---|---|---|---|
1443030262 | 0-300 | 0,01 | ±0,030 | 12N | Cast iron | Error & Temp comp. Preset. | max 50 m | + |
1443050262 | 0-500 | 0,01 | ±0,040 | 12N | Cast iron | Memory | max 50 m | + |
1443100262 | 0-1000 | 0,01 | ±0,050 | 12N | Cast iron | Max/Min | max 50 m | + |
1443150262 | 0-1500 | 0,01 | ±0,070 | 12N | Cast iron | Limits | max 50 m | + |
1443200262 | 0-2000 | 0,01 | ±0,090 | 12N | Cast iron | Limits | max 50 m | + |
FORCE WHEEL COMPUTERIZED HEIGHT GAUGE
Item No | Range (mm) | Resolution (mm) | Accuracy (mm) | Fine adjust. wheel with Force | Functions | Data output (USB/Wireless) | Calibration (ISO 17025) |
---|---|---|---|---|---|---|---|
1443030264 | 0-300 | 0,01 | ±0,030 | 8N | Error & Temp comp. Preset. | max 50 m | + |
1443050264 | 0-500 | 0,01 | ±0,040 | 8N | Memory Max/Min | max 50 m | + |
1443060264 | 0-600 | 0,01 | ±0,040 | 8N | Limits | max 50 m | + |
Getting Started
Cleaning: Clean the oil from the measuring surfaces of the height gauge by cloth.
Charging: For recharging the caliper (Li-Pol rechargeable battery), connect it with a standard USB cable to a charger device. DO NOT LEAVE UNCHARGED CALIPER FOR A LONG TIME. THIS MAY RESULT TO INTERNAL BATTERY FAILURE!
Powering On: Turn on the caliper by pressing the ON button [Power Button Icon] (1 sec).
Zero Setting: For zero setting, use the Force control module. The line inside the lens must be aligned with the outside line. Press the ZERO button [Zero Button Icon] on the Touchscreen for ZERO position setting.
Saving Data: To save measuring data to the internal caliper's memory, touch the data area on the screen or use a short button push. You can view saved data through the menu or send it via USB or Wireless connection to Windows PC, Android, or iOS devices.
Key Functions
Main Menu and Navigation
The device features a main menu with various function categories accessible via the touchscreen. Key areas include:
- Functions Status [Function Status Icon]
- Color Indication Go/NoGo [Color Indicator Icon]
- Zero Setting [Zero Button Icon]
- Main Menu [Menu Icon]
- Battery Status [Battery Status Icon]
- mm/inch Conversion [Unit Conversion Icon]
- Memory Manager [Memory Icon] (Folders system, transferring data from memory to PC)
Limits Go/NoGo
Set upper and lower limits for measurements. Status indication on the main screen.
- MAX - NoGo over MAX value
- MIN - NoGo over MIN value
- RANGE - selecting GO range
- NONE - No active mode
Max/Min
Displays the maximum and minimum measured values. Includes ENABLE/DISABLE mode.
Formula Mode
Allows calculations using formulas like Ax²+Bx+C. Available formulas include square value and radius/sphere calculations for indicators. Example: for value x², set B=2.
Math. Error Compensation
Corrects measurement errors by compensating actual values. Use up/down buttons to update the green (compensated) value to the correct value. Press OK for compensation correction. The instrument recalculates values based on corrected points.
Resolution
Selectable measurement resolution up to 0.0001mm.
Timer Mode
For saving or transferring data by timer. Select timer period. For deactivation, reset to zero.
Temperature Compensation
Recalculates measurement values based on material properties and temperature. Supports 7 types of materials (e.g., Glass, Quartz, Solid alloys, Mo) and manual temperature setting.
Extra (Axis Mode)
Provides +/- value indication and allows selecting normal or inverted axis mode.
Wireless Connection
Supports wireless data transfer up to 15m, or up to 50m with an external antenna. Includes options for Normal/1 min transmission modes and Wireless status display.
USB Connection
Options include Mode OFF, UART OFF, Keypad ON. Connects via USB.
Display Setting
Customize screen settings such as rotation (0, 90, 180, 270 degrees), sleep mode, and brightness level.
Memory Manager Settings
Supports Standard/Folder mode. In Folder mode, you can set the quantity of values in each folder.
Calibration Date
Allows setting and managing the calibration date. Saving or transfer data by Timer is also available here.
Device Info
Provides information about the device, including firmware version (FW), MAC address, and Device ID, for easy connection.
Link to Software
Provides a link to download free software for Windows, Android, and iOS. Both free and pro versions are available. [QR Code for software download]
Connectivity and Data Transfer
Microtech Intelligent instruments have internal memory for data collection. Data can be transferred to peripheral devices without data loss.
- Wireless Transfer: Up to 15m, or up to 50m with an external antenna.
- USB Transfer: USB port can be used to transfer data directly to a Windows PC.
Data Transfer Options:
- Saving Data to XLS, CSV formats [Excel Icon]
- Saving Graph [Graph Icon]
- Voice Mode [Voice Icon]
- Transfer Data to CAD, SPC or other software [CAD/SPC Icon]
- Transfer Data to Excel or other table editors [Excel Icon]
Quality Control Results [QC Icon]
Company Information
MICROTECH innovative measuring instruments
Address: 61001, Kharkiv, Ukraine, str. Rustaveli, 39
Tel.: +38 (057) 739-03-50
Website: www.microtech.ua
Email: tool@microtech.ua
Content subject to change without prior notice. Edition: M1030_0520