1. Description
Use
Within a Home + Control installation, the Module Control with Netatmo creates a network of connected equipment via radio and acts as a gateway to the IP network using a Wi-Fi connection.
To create a connected installation, you need:
- A Module Control
- Connected products (see chapter 7 Accessories)
The module is usable:
- With the Legrand smartphone application "Home + Control" [App Store logo] [Google Play logo]
- With voice assistants (Compatible with major voice assistants on the market) [voice assistant icon]
Technology
Wi-Fi ↔️ RF modular gateway connecting the internet IP network to the network of connected products "... with Netatmo". Installs in an electrical cabinet.
Connected Network
Maximum number of connected products in the network: 100
Recommendations
For the protection of the Module Control, it is recommended to use a circuit breaker or a gG fuse with a nominal current of ≤ 16 A.
2. Technical Characteristics
2.1 Electrical Characteristics
Power Consumption: 2 W Maxi
Nominal Supply Voltages: 100 to 240 V~
Nominal Frequency: 50 Hz/60 Hz
Electromagnetic Compatibility (EMC) Immunity: Conforms to EN 301 489-1:
- Immunity to electrical transient surges.
- Immunity to shock waves (2 KV)
Altitude Influence: No influence up to 2,000 m
Rated Operational Voltage (Ue): Ue = 100 to 240 V~
Rated Frequency: 50 Hz/60 Hz
Radio Frequency Characteristics
- Standard: IEEE 802.11, IEEE 802.15.4
- Frequencies: 2.4 to 2.4835 GHz
- Transmitter Output Power: < 100 mW
- Max distance between 2 connected devices: 50 m in open field
2.2 Mechanical Characteristics
Protection Degree:
- Protection of terminals against touch: IP2x (cabled device) (IEC/EN 60529)
- Protection of the front face against touch: IP3XD (IEC/EN 60529)
- Class II, front face insulated.
- Protection against mechanical impacts: IK04
2.3 Material Characteristics
Plastics: Self-extinguishing polycarbonate. UL 94 classification: V1
2.4 Climatic Characteristics
Operating Ambient Temperature: Min. = -5 °C / Max. = +45 °C
Storage Ambient Temperature: Min. = -40 °C / Max. = +70 °C
3. Dimensions and Weight
Width: 2.5 modules - 45 mm wide
Average Weight: 86 g
Packaged Volume: 0.62 dm³
Overall Dimensions
The module has a width of 45 mm, fitting 2.5 standard electrical modules. Its height is approximately 88.9 mm and depth approximately 61 mm. The terminals are located on the front face.
[Diagram description: A technical drawing showing the module's front and side views with dimensions labeled: Width 45mm (2.5 modules), Height 88.9mm, Depth 61mm. Terminal block details are visible.]
4. Positioning
Mounts on a symmetrical rail EN/IEC 60715 or DIN 35.
Mounting Positions
The Module Control With Netatmo can be mounted in a Vertical, Horizontal, or Flat position.
Positioning in a Row
The product's profile and terminal positioning allow for the passage of single-phase, three-phase, and Plug In connection combs in the upper part of the product. This flexibility allows the Module Control to be positioned freely within the row, enabling connection via combs to products on the same rail.
[Diagram description: Shows different possible mounting orientations (vertical, horizontal, flat) and how the module fits within a row of electrical components, illustrating the use of connection combs.]
5. Connection
5.1 Power Wiring
Connection to screw terminals (cage type) for control and power:
- Terminal Type: Cage
- Depth: 9 mm
- Recommended stripping length: 9 mm
- Screw Head: Slotted 3.5 mm
- Screw Type: M 3.5
- Tightening Torque: 0.5 Nm
- Conductor Type: Copper cables
Accepted Cable Sections (Copper Cables)
Cable Type | Without Ferrule | With Ferrule |
---|---|---|
Rigid Cable | 1x (1 to 2.5 mm²) 2x (1 to 2.5 mm²) | - |
Flexible Cable | 1x (1 to 2.5 mm²) 2x (1 to 2.5 mm²) | 1 x (1 to 2.5 mm²) |
Recommended Tools
- For wiring terminals: Screwdriver with a 3.5 mm blade.
- For clipping: Screwdriver with a 5.5 mm maximum blade.
5.2 Wiring Diagrams
[Diagram description: Step-by-step illustration of how to connect the power supply to the Module Control. It shows removing a cover, connecting the Phase and Neutral wires to the designated terminals, and then replacing the cover. The diagram also indicates the location of the power terminals.]
Steps:
- [arrow-right] Detach the cover to remove it.
- Connect the power supply to the Module Control.
- Clip the cover back onto the base.
Important: Branch the Module Control after a protection circuit breaker. If conditions permit, existing electrical protections in the electrical panel can be reused.
6. Configuration
Operation Mode Visualization
Indicated by an indicator light on the front of the product:
Color | State | Signification |
---|---|---|
(No light) | Off | Normal operating mode |
White | Solid | Transient state - Start-up phase |
Green | Solid | Transient state - Open network for pairing connected products |
Red | Solid | Transient state - Configuration initialization phase (factory reset) |
Configuring the Module Control in an Electrical Cabinet
To configure the Module Control, the general circuit breaker must be turned OFF. After wiring the installation, turn the circuit breaker back ON so that the connected devices are powered simultaneously.
- [power-off] Turn OFF the power at the general circuit breaker.
- [power-on] Turn ON the power at the general circuit breaker once the installation is completed and checked.
Press and hold the Module Control configuration button for more than 3 seconds, until the indicator light briefly illuminates green, then release.
[Diagram description: Shows a button being pressed for more than 3 seconds (>3s), with an indicator light turning green. A subsequent diagram shows a timer indicating >30s, and then a brief press (<1s) of the button.]
The configuration indicators of the "... with Netatmo" products present in the installation will light up solid green.
Briefly press the Module Control configuration button to finalize the installation. The configuration indicators will turn off.
Internet Box Configuration Path
- If no Internet box is present in the installation: Configure via the "Home + Pro" application. [Home + Pro logo]
- If an Internet box is already present in the installation: Configure via the "Home + Control" application. [Home + Control logo]
Resetting the Module Control Configuration
Press and hold the Module Control configuration button for more than 5 seconds until the configuration indicator lights up solid red.
Other Configurations & Actions
All other functionalities and configurations are explained step-by-step within the mobile application.
7. Accessories (Non-exhaustive List)
[Description of icons: A set of icons representing different product categories. The first icon depicts modules for an electrical panel. The second icon shows sockets, switches, and micromodules. The third icon represents wireless accessories and controls.]
8. Marking
Module Control Marking
Front Face Marking:
An icon indicating a connected product. [connected product icon]
Presence of a QR code sticker: "DOWNLOAD SMARTHOME APP". [QR code]
Lateral Marking:
Marking according to obtained national approvals.
Product Label Information: "Made in China", RF, 2W Max, Legrand, BP 30076, 87002 LIMOGES CEDEX FRANCE, legrand.com. Also shows cable size compatibility: max 2x 2.5mm².
9. Standards and Regulations
Conformity to Standards:
- EN 301 489-1
Environmental Compliance:
Response to European Union Directives: Compliance with Directive 2011/65/EU (RoHS), as amended by delegated Directive 2015/863, on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Compliance with Directives 91/338/EEC of 18/06/91 and Decree 94-647 of 27/07/04.
REACH:
If substances identified as SVHC (Substances of Very High Concern) according to REACH regulation (1907/2006) are present in products with a concentration greater than 0.1% by mass/mass, they are declared within the European SCIP database. As of the publication date of this document, none of the substances listed in Annex XIV are present in this product.
WEEE:
WEEE Directive (2012/19/EU): The sale of this product includes a contribution to the designated environmental organizations in each European country responsible for the end-of-life management of products covered by the EU Directive on Waste Electrical and Electronic Equipment.
Plastics:
- Halogen-free plastics.
- Part marking conforms to ISO 11469 and ISO 1043.
- EN ISO 306: 2004, Plastics - Thermoplastics Materials - Determination of Vicat softening temperature (VST) (ISO 306: 2004).
- ISO 7000: 2004, Graphical symbols for use on equipment - Index and synopsis.
Packaging:
Packaging designed and produced in accordance with Decree 98-638 of 20/07/98 and Directive 94/62/CE.
10. Other Information
XLPro Calcul:
Calculation note creation software, intended for installers, design offices, and maintenance operators. Defines the electrical characteristics of a low-voltage installation in compliance with applicable standards.
XLPro³ Tool Sélectivité et filiation / Legrand Sélectivité et filiation:
Software dedicated to installers, panel builders, and design offices. Defines selectivity and backup values for associations of electrical devices and obtains tripping curves for selected products.
XLPro Tableaux:
Electrical panel design software, intended for panel builders and electrical panel designers. Designs the electrical distribution of the panel, produces electrical diagrams, lists products, and provides overall project costing.
[information] Notice: Detailed mounting information is available in the online catalog.
For more technical information, contact Legrand technical support.
Unless otherwise indicated, the data reported in this document refers exclusively to test conditions according to product standards. For different product usage conditions, within an electrical cabinet or any other installation context, refer to the equipment's regulatory requirements, local regulations, and system design specifications.