MR6000 Viewer Instruction Manual

1. Introduction

The MR6000 Viewer is a PC application designed for viewing and analyzing measurement data recorded by the MR6000 Memory HiCorder on a personal computer.

Supported InstrumentsProduct Name
MR6000, MR6000-01Memory HiCorder

MR6000 Viewer Functions:

  • Display measured waveforms
  • Search waveforms
  • Perform numerical calculation, waveform calculation, and FFT calculation
  • Convert measurement data to CSV format

2. System Requirements

To use the MR6000 Viewer, the following minimum computer system configuration is required:

CategoryRequirement
OSWindows® 10 64-bit version
  • Version 1703 Build 15063 or later (Supports recent service packs as of May 11, 2021.)
  • Japanese/English/Chinese Operating Systems (displayable in each language)

How to check your system's version:

  1. Press the ⊞ (Windows) key and R on your keyboard to display the Run dialog box.
  2. Enter WINVER in the [Open:] field.
  3. Click OK. The OS version number will be displayed.
MemoryMinimum 8GB
DisplayResolution of 1280×1024 or better
Installation accountAdministrator
Execution accountAdministrator

Note:

  • MR6000 Viewer does not support the 32-bit version of Windows 10.
  • Certain PC environments may not support full operation of the MR6000 Viewer despite meeting the minimum requirements.

3. Setup

To install the software MR6000 Viewer, refer to the MR6000 Viewer Installation Procedures.

4. Using the Software

Perform the following steps using an administrator account.

4.1. Launching the Application

From the [Start] menu, select [HIOKI] - [MR6000 Viewer] to launch the application.

[Illustration shows the Windows Start menu with HIOKI and MR6000 Viewer highlighted.]

4.2. Loading Measurement Data

Use either of the following methods to load a waveform onto the application:

  1. Click the ? (Folder Icon) to open the file selection screen.
  2. Select the storage media and folder containing the desired file, then double-click the file to load it.

Alternatively, drag and drop the waveform data file onto the application screen.

[Illustration shows a file explorer window for selecting a .MEM file and a waveform display area where a file can be dropped.]

4.3. Saving Data

Click the ? (Save Icon) to save any of the following:

  • Waveform data
  • Screen shot
  • Numerical calculation results
  • Settings

Procedures:

  1. Click the ? (Save Icon).
  2. Click [Folder:] to select the target directory to save the file. Edit the [Type] or [Channel] as required.
  3. Click [Execute] to proceed.

[Illustration shows the Save dialog box with fields for Folder, File name, Type, Channel, etc., and buttons for Execute and Cancel.]

Note: The MR6000 Viewer operates differently from the MR6000 Memory HiCorder. A [HIOKI_MR6000] folder will not be automatically created. Please save your data directly into the appropriate folder.

4.4. Zoom In and Zoom Out Waveforms

To zoom in and out with respect to the time axis, move your mouse over the area below the waveform and rotate the center wheel of the mouse. You can also zoom by positioning the mouse arrow on any part of the waveform and pressing the [Ctrl] key while rotating the center wheel.

[Illustration shows a waveform with a horizontal yellow arrow indicating zoom on the time axis.]

To zoom in and out with respect to the waveform's vertical axis, move your mouse over the area to the left of the waveform and rotate the center wheel of the mouse. You can also zoom by positioning the mouse arrow on any part of the waveform and pressing the [Shift] key while rotating the center wheel.

[Illustration shows a waveform with a vertical yellow arrow indicating zoom on the vertical axis.]

4.5. Quitting the Application

Click the ❌ (Close Button) on the top right corner of the application window to quit the application.

Models: MR6000 Viewer, Memory HiCorder, MR6000 Viewer Memory HiCorder, HiCorder

PDF preview unavailable. Download the PDF instead.

MR6000 Viewer manual en 7 Microsoft Word 2013 Microsoft Word 2013

Related Documents

Preview Hioki MR6000 & MR6000-01 Memory HiCorder: Instruction Manual
Comprehensive instruction manual for the Hioki MR6000 and MR6000-01 Memory HiCorders, detailing measurement procedures, data analysis, advanced functions, and system configuration.
Preview HIOKI GENNECT One SF4000: Integrated Measurement Operations Software
HIOKI GENNECT One SF4000 software provides a centralized platform for controlling and managing data from multiple HIOKI measuring instruments. It offers real-time data visualization, automated file transfer, remote instrument operation, and comprehensive data analysis capabilities, enhancing measurement efficiency and workflow.
Preview HIOKI MR8875: 1000 V Direct Input Multi-channel Logger
Discover the HIOKI MR8875, a compact and versatile 1000 V direct input multi-channel data logger. It offers high-speed recording, flexible input module options, and advanced analysis capabilities suitable for industrial robots, R&D, automotive testing, and power equipment analysis.
Preview HIOKI BT5525 Sample Application Manual: Installation, Operation, and Features
Detailed guide for the HIOKI BT5525 Sample Application, covering system requirements, installation, connecting the BT5525 instrument, Insulation Resistance Test, BDD Analysis, data saving options, and troubleshooting.
Preview HIOKI LR5031 Instrumentation Logger Instruction Manual
This manual provides essential information and warnings for the safe operation and maintenance of the HIOKI LR5031 Instrumentation Logger. Learn about product overview, measurement preparations, settings, data processing, organization, options, specifications, and troubleshooting.
Preview HIOKI LR5031 Instrumentation Logger Instruction Manual
This manual provides comprehensive instructions for the HIOKI LR5031 Instrumentation Logger, covering its features, operation, settings, data analysis, maintenance, and troubleshooting. Learn how to effectively use this device for accurate data logging.
Preview HIOKI CM3286-50 AC 钳形功率计 用户手册
HIOKI CM3286-50 AC 钳形功率计用户手册,提供详细的操作指南、安全信息、测量功能(电流、电压、功率、频率、相位检测)及规格。支持可选的 Z3210 无线适配器和 GENNECT Cross 应用。
Preview HIOKI 3169-20/21 Clamp On Power HiTester Instruction Manual
Comprehensive instruction manual for the HIOKI 3169-20 and 3169-21 Clamp On Power HiTesters. Covers product overview, features, setup, measurement procedures, specifications, and maintenance for electrical power analysis.