ANDTE Home Dehumidifier User Manual

Model: PD161A

Please read this user manual before operating and save for future reference.

Welcome

Thanks for choosing ANDTE dehumidifier!

ANDTE is dedicated to keeping people healthy, comfortable and more enjoyable by offering quality appliances ranging from dehumidifiers to ice makers, and more. From breathing easier in your office to upgrading your kitchen appliances, we hope ANDTE could help you every step of the way.

READ THIS MANUAL INSTRUCTION CAREFULLY BEFORE USING THE UNIT. PLEASE KEEP THIS FOR FUTURE REFERENCE.

ANDTE PD161A home dehumidifier reduces humidity to comfortable levels in a short period of time. This dehumidifier has a sturdy housing to withstand harsh environments, is safe and easy to use, guarantees long-term use and easy maintenance, plus we use a copper tube condenser and high quality and accurate sensors, it will be more effective and last longer.

Before plugging in your new dehumidifier, we suggest that you read this user manual as it contains important safety information, operation instructions, troubleshooting, maintenance tips, and warranty information to ensure the reliability and longevity of your dehumidifier.

We're always just an email away

To access customer support, please email to AndteServices@outlook.com with your purchase order.

Thank you again!

Before First Use

Please leave the dehumidifier sitting outside the box for 24 HOURS before plugging it in.

The dehumidifiers may have been tilted or placed upside down during shipping. Leave the dehumidifier sits for 24 hours so the oil in the compressor can settle from the move. Not doing so can affect the performance or lifespan of the dehumidifier.

NOTE: To continuously improve its products, ANDTE reserves the right to modify this information without prior notification. For any questions during assembly, please check the instructions on the product page for reference. Or contact our customer service with any questions, comments, or concerns. We are online 24H for you. Thank you for using ANDTE products in your home!

Made in China

Important Safety Instructions

To prevent injury and property damage, the following instructions must be followed when using the dehumidifier.

Warning

Caution

Parts Identification

Dehumidifier Exterior:

Dehumidifier Front/Side View:

NOTE: Do not cover or block the air inlet or outlet.

Operation Instructions

1. Position Your Dehumidifier Properly

2. Understand the Control Panel

The control panel features the following indicators and buttons:

Power Button and Indicator: Press the POWER button once to turn on/off the dehumidifier. When the dehumidifier has been turned off, the LCD screen turns blank. The indicator above the POWER button will flash when the compressor has not kicked on and will turn to solid green when the compressor kicks on.

Note: When the POWER button indicator flashes, it typically means:

3. General Operation

Note: This dehumidifier may have been tilted or placed upside down during shipping. To ensure this dehumidifier works properly, please ensure this dehumidifier is upright for at least 24 hours before initial use.

  1. Plug In: Plug the power cord into a properly grounded 110-120 volt AC outlet. The control panel will light up briefly. Press the POWER Button to turn the dehumidifier on. If the "FULL" indicator is on, remove and re-install the water bucket properly.
  2. Start Up: Press the POWER button to turn the dehumidifier on. It will run with the default setting of 30% set humidity at low fan speed. The LCD screen displays the room humidity reading.
  3. Set Humidity: Press the SETTING button repeatedly to choose a desired humidity level between 30%-80% in 5% increments. Wait for 5 seconds for the setting to stabilize.
    • It is recommended to set the humidity at least 10% lower than the room humidity level.
    • If the set humidity level is 30%, the dehumidifier will run continuously in CONTINUOUS Mode.
    • If the target humidity level is set between 35-80%, the dehumidifier will run in Humidstat Mode, automatically stopping or restarting to maintain the room humidity within ±3% of the set-point.
    • The dehumidifier will automatically stop when the water bucket is full or when the room humidity reaches the set-point.
  4. Set Fan Speed: Press the FAN button to change the fan speed between HIGH and LOW. The indicator light will show the selected setting. Higher fan speed removes moisture quicker.
  5. Shut Down: Press the POWER button again to shut down the dehumidifier.

Timer Setting

The TIMER function allows you to set a delay AUTO-ON or delay AUTO-OFF for the dehumidifier, from 1 hour to 24 hours.

To set the TIMER:

  1. Press the TIMER button once; the TIMER indicator will illuminate and the LCD will flash "00".
  2. Press the TIMER button repeatedly to change the delay timer in 1-hour increments, up to 24 hours.
  3. Wait for 5 seconds after selecting the target timer value for the setting to register automatically.
  4. After TIMER setting, the control will count down the remaining time until AUTO-ON or AUTO-OFF.
  5. After the timer function is enabled, press the TIMER button again to check the time remaining.

Notes:

Smart Functions

Auto Shut Off

When the water bucket is full and/or the humidity setting is reached, the dehumidifier will shut off automatically.

3-Minute Delay Protection Mechanism

To prevent damage, the dehumidifier will not start operation immediately after a cycle ends or interruption. It waits 3 minutes before restarting the compressor. During this time, only the fan runs, and the power button indicator flickers until the compressor starts.

Auto Defrost

When frost builds up on the evaporator coils, the compressor cycles off, and the fan continues to run until the frost disappears. The dehumidifier will then restart automatically.

Auto-Restart

If the dehumidifier shuts off unexpectedly due to a power cut, it will restart with the previous function settings (humidity and fan speed) once power is restored.

Removing Collected Water

1) Emptying the Water Bucket

When the bucket is full, the dehumidifier shuts down, beeps for 5 seconds, and the FULL indicator illuminates. Do not move the dehumidifier at this time to avoid spilling water.

To remove and empty the collected water:

  1. Gently remove the bucket by gripping both sides and pulling outward.
  2. Pour the condensate out from the side without the float to prevent it from being flushed away.
  3. Replace the water bucket in the dehumidifier. The dehumidifier will not function without the bucket installed.

2) Continuous Draining

Water can be automatically emptied into a floor drain by attaching the included drain hose. (You can use any other hoses with an inner diameter of 5/8 inches.)

To Achieve Continuous Drain by Gravity:

  1. Remove the water bucket.
  2. Find the drain port on the back of the dehumidifier.
  3. Attach one end of the drain hose securely to the drain port.
  4. Replace the water bucket in the dehumidifier properly.
  5. Direct the other end of the hose down to a suitable drainage facility, like a floor drain. The drainage facility should be lower than the drain outlet of the dehumidifier.

Notes:

Diagrams showing bucket removal, pouring water, and re-installation are described above. Diagrams showing hose placement: Two incorrect (❌) with kinks or water submersion, one correct (✔️) with a downward slope.

Care & Cleaning

To avoid electric shock, turn off and disconnect the dehumidifier from the power source before cleaning or maintenance.

1. Clean the Vent and Case

2. Clean the Reservoir

NOTE: Do not clean the reservoir in a dishwasher.

3. Clean the Air Filter

The air filter should be cleaned approximately every 2 weeks. More frequent cleaning may be needed if there is significant dander or fur in the air.

Follow the steps below to clean the filter:

NOTE: DO NOT operate the dehumidifier without a filter, as dirt and lint will clog it, reducing performance.

Store the Dehumidifier

When not using the dehumidifier for a long period, follow these steps for cleaning and proper storage:

Troubleshooting

ProblemPossible CausesSolutions
Dehumidifier can not turn onThe power cord is unplugged.
The fuse is blown or circuit breaker is tripped.
Water bucket is full or not in the proper position.
Plug it in.
Check the fuse or the circuit breaker.
Make sure the water bucket is empty and has been installed properly.
Dehumidifier is on, but it does not run.The room humidity has reached the set-point and the dehumidifier enters into Standby Mode where the power indicator and the LCD reading flash.
The room humidity is lower than set humidity, so the dehumidifier enters into Standby Mode where the power indicator and the LCD reading flash.
The dehumidifier is in the defrosting process.
Set a lower humidity or let the dehumidifier keep standby.
The set humidity needs to be at least 5% (recommend 10%) lower than room humidity.
It is normal the compressor ceases while defrosting process.
Insufficient dehumidifyingInsufficient dehumidifying time.
The room has not been sealed properly.
Air filter is dirty.
Air flow has been blocked.
There is something giving off water vapor in the room.
Room temperature is low.
The dehumidifier size is too small for application.
When first installed, allow at least 3-4 days to maintain the desired RH.
Ensure that all doors, windows and other openings are closed.
Clean the air filter.
Ensure there are no obstructions blocking the airflow.
Remove those items or turn off such devices that give off vapor in the room.
Heat up the room.
Increase the quantity of dehumidifier. Or change to a higher capacity dehumidifier.
Dehumidifier operates continuouslyCheck if the dehumidifier is in CONTINOUS MODE.
Room humidity is too high.
Doors and windows are open.
Don't set the humidity too low. Typically, 40-50% are good settings to use.
Change humidity settings. Or change to a higher capacity dehumidifier.
Ensure that all doors, windows and other openings are closed.
NoiseThe dehumidifier's not positioned level.
The water bucket is not in proper position.
The air filter is clogged.
Position the dehumidifier on a level surface.
Re-install the water bucket properly.
Wash the filter.
Frost appears on the coilsThe dehumidifier has been turned on recently.
Room temperature is close to or lower than 60°F.
This is normal frost builds up on the coils, especially when the room temperature is low. The dehumidifier will defrost automatically.
Water leakageHose connection is loose.Check the hose connection. Try to attach the other end of the hose to the outlet.
Water does not drain from the hoseHose connection is loose.
Water flow has been restricted.
Check the hose connection. Try to attach the other end of the hose to the outlet.
Hoses more than 7 feet long may not drain properly. It is recommended to keep the hose as short as possible for proper draining. The hose must be placed lower than the bottom of the dehumidifier, and be kept flat and smooth without kinks.
Humidity always shows "25%RH" (there is a big difference from the actual humidity)Humidity sensor failure?Set the humidity to 30%RH; the dehumidifier can still continue to work, and can be used normally.
Repair and replace the humidity sensor.
Humidity always shows "99%RH" (there is a big difference from the actual humidity)1. Water on the surface of humidity sensor?
2. Humidity sensor failure?
The dehumidifier is not affected and can continue to work, and can be used normally.
Please let the dehumidifier keep working for a period of time; after the water on the surface of the humidity sensor is removed, it will return to normal.
Repair and replace the humidity sensor.

Safety Precautions

(Note: The following points are described with accompanying illustrations in the original document.)

Service

ANDTE offers a limited 1-year free warranty on this PD161A dehumidifier, with original proof of purchase (order number or other information to prove a genuine purchase). The warranty covers defects arising from faulty manufacture, parts, or workmanship during the warranty period.

During the warranty period, for damaged parts, ANDTE will provide a replacement part if it can restore normal use. The warranty does not apply where damage is caused by factors including, without limitation:

ANDTE will inspect the dehumidifier through photos or videos to troubleshoot and solve problems. These are general terms for warranty service; customers are urged to reach out with any issue, regardless of warranty terms.

For more warranty information, please contact us at AndteServices@outlook.com.

Warranty and Service

If you have an issue with an ANDTE product, please contact us at AndteServices@outlook.com, and we will do our best to resolve it for you.

Support Hours

24 Hours available.

*Please have your order number ready before contacting customer support.

(Note: The document mentions a "Product Certification" and "OQC" stamp, indicating quality inspection.)

PDF preview unavailable. Download the PDF instead.

91c5812c-ac88-4e65-8eea-ef8b1f6b6ee4 Corel PDF Engine Version 18.1.0.661 CorelDRAW X8

Related Documents

Preview ANDTE Commercial Dehumidifier User Manual - Models DE260, DE305
Comprehensive user manual for ANDTE commercial dehumidifiers, covering setup, operation, safety guidelines, maintenance, troubleshooting, and warranty information for models DE260 and DE305.
Preview ANDTE Commercial Dehumidifier DS190P User Manual
User manual for the ANDTE DS190P commercial dehumidifier, covering safety information, operation instructions, maintenance, troubleshooting, and warranty. Learn how to use and care for your ANDTE dehumidifier.
Preview ANDTE PD161A Home Dehumidifier User Manual
Comprehensive user manual for the ANDTE PD161A Home Dehumidifier, covering setup, operation, maintenance, troubleshooting, and safety precautions. Learn how to effectively use your dehumidifier for optimal performance and longevity.
Preview ANDTE Commercial Dehumidifier DE270P User Manual
Comprehensive user manual for the ANDTE DE270P commercial dehumidifier, covering setup, operation, maintenance, troubleshooting, and safety precautions. Learn how to use and care for your ANDTE dehumidifier.
Preview ANDTE PD50K Home Dehumidifier User Manual - Operation, Safety, and Troubleshooting
Comprehensive user manual for the ANDTE PD50K Home Dehumidifier. Includes setup, operation, safety warnings, maintenance, fault finding, and warranty information.
Preview ANDTE Commercial Dehumidifier DY155 User Manual
User manual for the ANDTE Commercial Dehumidifier, Model DY155. This guide provides instructions on operation, safety precautions, maintenance, and troubleshooting for the ANDTE dehumidifier.
Preview ANDTE DE260 Commercial Dehumidifier User Manual
User manual for the ANDTE DE260 commercial dehumidifier, providing instructions on operation, maintenance, troubleshooting, and safety precautions. Learn how to use and care for your dehumidifier for optimal performance and longevity.
Preview ANDTE DY155 Commercial Dehumidifier User Manual
Comprehensive user manual for the ANDTE DY155 commercial dehumidifier. Learn about setup, operation, maintenance, safety precautions, and troubleshooting for optimal performance.