Beok Wireless One-to-One Temperature Controller Manual
Application
The wireless intelligent one-to-one digital thermostat is a temperature controller suitable for underfloor heating systems. By comparing the ambient temperature with the set temperature, it controls the working status of the gas wall-mounted boiler and electric valve in the underfloor heating system to achieve goals of regulating ambient temperature, comfort, and energy conservation.
Electrical Specifications
Specification | Value |
Equipment power supply | 3 x 1.5V alkaline AA batteries |
Protection grade | IP20 |
Temperature sensor | NTC |
Temperature Accuracy | ±0.5°C (adjustable) |
Self-consumption power | <170uA |
LOAD | 3A (resistive) |
Operating Instructions
- Power On/Off: Press and hold the [power] button to shut down and close all valves. Short press the [power] button to turn on the device.
- Mode Conversion: In the power-on state, short press the [mode] key to switch working modes. The LCD display indicates manual mode, and the display indicates automatic mode.
- Temporary Mode: Clicking the [up] or [down] keys in the power-on state allows direct adjustment of the set temperature. If in automatic mode, it switches to temporary mode.
- Adjustment Key: When turned on, press the [up] or [down] keys to adjust temperature and other parameters.
- Child Lock Function: Press and hold the [up] and [down] keys for 5 seconds while the device is turned on. A [lock] icon appears on the right side of the display screen, indicating the lock is active.
- Unlock: Press and hold the [up] and [down] keys for 5 seconds to unlock the panel.
Advanced Device Options Settings
Press and hold the [settings] key for 5 seconds while the device is turned off to enter advanced parameter settings. Press [up] to switch parameters, press [down] to adjust.
Parameter No. | Parameter Name | Default | Function | Range |
1 | Temperature compensation | 0.0 | Temperature compensation | -9.9 ~ 9.9 |
2 | Temperature difference startup | 1 | Startup by temperature difference | 0.5 ~ 10 |
3 | Antifreeze function | ON | Turn on/off the device's antifreeze function | ON/OFF |
4 | Upper temperature limit | 35°C | Set the upper temperature limit value | 15°C ~ 60°C |
5 | Key sound | ON | Turn on/off device button sound | ON/OFF |
6 | Restore factory settings | --- | Set to restore factory settings. Press [mode] to adjust display to "---", then press confirm key to restore. | N/A |
Weekly Programming Mode
The network programming mode needs to be operated on the APP, working in six cycles per day. (Single machine version without programming function).
Scheduled temperatures:
- 06:00 - 20°C
- 08:00 - 16°C
- 11:30 - 16°C
- 12:30 - 16°C
- 17:00 - 22°C
- 22:00 - 16°C
Device Code Connection Settings
- In the power-on state, long press the [code] key on the receiving panel until its signal light starts flashing.
- In the power-on state, long press the [down] key on the transmission panel until the signal light on the reception panel stops flashing.
- When the device is in heating mode, adjust the set temperature to be higher than room temperature. At this time, all three indicator lights on the output signal receiving panel will light up, indicating successful code matching.
Device Network Connection Settings
When the temperature controller transmitter panel is turned on, press and hold the [wifi] key for 5 seconds until the [wifi] icon flashes on the temperature controller display screen. The controller enters the connected state. Find the temperature controller product (Bluetooth+WIFI model) in the 'small household appliances' device list within the app. Under the designated distribution mode, click the confirmation button on the page, select the Wi-Fi that can connect to the Internet in the device work area, and enter the Wi-Fi password. Click 'Next', then 'Connect' according to the page prompts. Follow the on-screen instructions, find the prompt content, click 'Prompt content', and return to the app (e.g., Tuya app) to enter the distribution process.
Wiring Diagram
Please do not connect wires with electricity, and do not leave wire ends exposed!
Terminals: N, L (AC 220V power input), M, NO, COM, NC, NO1, NC1.
Wiring Instructions:
- Connect NO1 and N to a normally closed electric actuator.
- Connect NC1 and N to a normally open electric actuator.
- Connect M and N to an external circulation pump < 5A.
Note: Due to the involvement of strong electricity in some circuits of this product, installation must be carried out by a professional.
Panel Bracket
This section describes how to attach the thermostat panel to a bracket for mounting or placement.
Installation Steps
- Pry open the panel [pry open].
- Install expansion screw sleeves with a spacing of 59mm on the wall, place the backplate in the installation position, insert and tighten the screws [screw].
- Cover the panel and complete the installation [complete].
Alternatively:
- Insert the transmitter panel into the bracket [insert].
- After connection, it can be placed on the desktop, etc. [desktop].
Equipment Icon Description
- [Manual]: Manual mode
- [Auto]: Automatic mode
- [wifi]: WiFi icon
- [temp]: Real-time temperature
- [home-leaving]: Leaving home mode
- [code]: Code icon
- [set temp]: Set temperature
- [adjust]: Adjustment key (Up/Down arrows)
- [output]: Device output icon
- [wireless]: Wireless icon
- [power]: Power icon
- [code]: Code key
- [power]: ON/OFF button
- [cooling]: Cooling icon
- [heating]: Heating icon
- [child lock]: Child lock icon
- [battery]: Device battery icon
Leaving Home Mode
The default temperature for Leaving home mode is 16°C.