Carrier FT5 Performance™ Fan Coil
Variable Speed Constant Airflow Motor - Puron Advance™ Refrigerant
Sizes 24-60
Product Data
The FT5 is a premium air handler that combines Carrier's proven fan coil technology with the environmentally balanced Puron Advance® refrigerant. It features Carrier's InteliSense™ technology, a connected system solution when paired with Internet-connected Ecobee smart thermostats, designed to deliver a smarter, faster, and more efficient service experience for homeowners. The FT5 offers an operational advantage through its variable speed ECM (Electronically Commutated Motor) when paired with a Carrier Performance™ heat pump or air conditioner utilizing Puron Advance® refrigerant.
Carrier has developed a new benchmark for superior indoor comfort and control, focusing on quiet, efficient, and comfortable operation.
Carrier's heat pump and air conditioning systems utilize Puron Advance® refrigerant (R-454B), a chlorine-free refrigerant positioned as the future for the residential heating and cooling industry. The FT5, using Puron Advance® refrigerant, maximizes performance for environmentally balanced systems. These systems offer 30% to 40% greater efficiency than standard heating and cooling systems, combining environmental responsibility with excellence in efficiency.
The FT5's benefits are driven by Carrier's expertise in ECM technology. These motors are highly efficient across all speeds, enabling the FT5 to operate at the precise speed required for optimal airflow delivery, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also simplifies installation quality for homeowners.
Carrier's ECM technology is particularly evident in the comfort advantages it provides. The InteliSense™ Board offers setup alternatives for technicians to maximize comfort and efficiency. For enhanced indoor comfort, homeowners can achieve precise control over both temperature and humidity in cooling and heating modes.
Further enhancing the FT5's performance is the factory-installed TXV (Thermostatic Expansion Valve), which improves efficiency and protects the compressor under all recommended conditions. Grooved tubing, louvered aluminum fins, and large face areas on the FT5 refrigerant coils contribute to superior efficiency and high SEER and HSPF performance. Carrier is recognized for its advanced condensate control, a hallmark of its multipoise fan coils. All components are housed within a rugged, pre-painted metal cabinet lined with high-density insulation. For ease of installation, the unit exterior features sweat refrigerant connections for leak-free performance and multiple electrical entry points for both high and low voltage service.
The units are assembled to comply with low leakage requirements, tested to ASHRAE 193 standard, achieving less than 2% cabinet leakage at 1 inch W.C. and 1.4% at 0.5 inches W.C.
Key Features
- Environmentally Balanced Refrigerant Technology: Utilizes Puron Advance®, a chlorine-free, non-ozone depleting refrigerant. Includes a refrigerant leak detection dissipation system for added safety. Features a Thermostatic Expansion Valve (TXV) optimized for Puron Advance® refrigerant performance.
- Energy Efficient Operation: Employs a Variable Speed Constant Airflow ECM motor that operates efficiently at all speeds, maximizing system efficiency and offering ultra-low power consumption during fan-only operation.
- Indoor Weather Control: Provides warm, comfortable heating air temperatures and unmatched humidity control, especially when paired with Carrier thermostats offering relative humidity controls.
- Airflow and Sound Technology: Features a diffuser air discharge section for high airflow efficiency and quiet, smooth operation. Offers high duct static capability. Meets stringent regulations for cabinet air leakage.
Technologies and Design Details
Condensate Control and Disposal Technology
- Minimizes standing water and microbial growth for improved Indoor Air Quality (IAQ) and reduced condensate line issues.
- Condensate fittings are repositioned away from turbulent airflow patterns near the blower for enhanced control.
- An overflow feature on slope coil units allows condensate to exit safely even with clogged primary and secondary lines.
- Tested for condensate disposal under conditions exceeding AHRI requirements.
- Includes primary and secondary drain connections compliant with HUD standards.
- All pans are constructed from injection-molded, glass-filled polycarbonate engineered resin with brass drain connections.
- Features high-density, super-thick cabinetry insulation with a vapor barrier and a pre-painted galvanized sheet metal cabinet.
Heat Transfer Technology
- Grooved tubing
- Lanced sine wave aluminum fins
- Discreet refined counter-flow refrigerant circuitry
- Bi-flow hard shut-off TXV metering device with mechanical fittings
Quality, Installation, and Service Features
- All units are multipoise.
- Provision for suspending from roof or ceiling joints.
- Modular cabinet design for 36 through 60 size units.
- Sweat connections for leak-free service.
- Multiple electrical entry points for application flexibility (high and low voltage).
- Low voltage terminal strip for secure connections within the cabinet.
- Cabinet construction incorporates innovations to prevent sweating.
Controls and Electrical Features
- InteliSense™ Board for optimized comfort, efficiency, and safe heater airflow operation.
- Easy plug connections for quick installation of accessory heater packages.
- Includes a 40VA 208/230V transformer.
- Features a replaceable 5A blade-type auto fuse to protect against transformer secondary shorts.
Filter Features
- Factory-supplied filter included.
- New standard-sized filter rack accommodates most common filter sizes.
Model Nomenclature
The model number indicates specific features:
Position | Feature | Example |
---|---|---|
1-2 | Product | F = Fan Coil |
3 | Type / Tier | T = Performance Series™, Variable Speed Constant Airflow ECM Motor |
4 | Refrigerant Type | 5 = Puron Advance® |
5 | Major Series | A |
6-7 | Nominal Capacity | 24 = 24,000, 36 = 36,000, 48 = 48,000, 60 = 60,000 BTU/hr |
8 | Electrical | N = 208/230V, 1 ph, 60 Hz |
9 | Cabinet Type / Metering Device | B = Modular (2-Piece), TXV; X = Singular, TXV |
10 | Electric Heater Size | 00 = No Heat |
11 | Coil Type | L = Aluminum |
12 | Cabinet Width | B = 17", C = 21", D = 24" |
Specifications
Models Available
2 Ton | 3 Ton | 4 Ton | 5 Ton |
---|---|---|---|
FT5ANXB24 | FT5ANXC36 FT5ANBC36 | FT5ANXC48 FT5ANBC48 | FT5ANBD60 |
Evaporator Coil
2 Ton | 3 Ton | 4 Ton | 5 Ton | |
---|---|---|---|---|
Face Area (sq ft) | 3.46 | 5.93 | 7.42 | |
Configuration | A | Slope | A | |
Metering Device | Puron Advance® R-454B, TXV | |||
Refrigerant Sweat Liquid Line Connection, in (mm) | 3/8 (9.5) ID | |||
Refrigerant Sweat Suction Line Connection, in (mm) | 3/4 (19.1) ID | 7/8 (22.2) ID | ||
TXV Replacement P/N | EA66YP004 | EA66YP002 | EA66YP005 | EA66YP006 |
Rows/Fins per Inch | 3 / 14.5 |
Blower & Motor
2 Ton | 3 Ton | 4 Ton | 5 Ton | |
---|---|---|---|---|
Air Discharge | Upflow, Downflow, Horizontal | |||
CFM (Nominal Clg/Htg) | 525, 700, 875, 1050 | 700, 875, 1050, 1225 | 875, 1050, 1225, 1400 | 1050, 1225, 1400, 1750 |
Motor HP (ECM) | 1/2 | 3/4 |
Filters
The fan coil filter rack accommodates most common size filters.
2 Ton | 3 Ton | 4 Ton | 5 Ton | |
---|---|---|---|---|
L x W in, (mm) | 16 x 20 (406 x 508) | 20 x 20 (508 x 508) | 24 x 20 (610 x 508) |
Cabinet Configuration Options
2 Ton | 3 Ton | 4 Ton | 5 Ton | |
---|---|---|---|---|
Singular (1-Piece) | Singular (1-Piece) or Modular (2-Piece) | Modular (2-Piece) |
Dimensions
Detailed dimensions for each unit size are provided in accompanying diagrams and tables. These diagrams illustrate front, top, and side views, showing critical measurements for installation and service access. Key connection points for suction and liquid lines, electrical entry points, and access panels are clearly indicated. Specific measurements are listed in tables, with units in both inches and millimeters.
For example, diagrams show:
- Front View: Illustrates coil access panel, filter access panel, and connection locations for upflow or horizontal applications.
- Top View: Shows disconnect or circuit breaker location, and blower/control/heater access panel.
- Side Views: Detail liquid line connection panels and alternate electrical entry points.
- Slope Coil Details: Show connection locations for upflow, downflow, and horizontal applications specific to slope coils.
Performance Data
The FT5 fan coil offers extensive performance data, including airflow delivery charts for various operating modes (cooling, heat pump heating, electric heating), cooling capacities, sound power levels, and correction factors for different conditions.
Airflow Delivery Charts (CFM)
Tables detail airflow delivery in CFM for different unit sizes and capacities under various operating modes:
- Table 4: Cooling Mode: Shows single-speed and two-speed application airflow for nominal cooling, cooling dehumidification, and fan-only operation.
- Table 5: Cooling Airflow with 37MU (2-Speed ODU): Provides cooling airflow when paired with a specific outdoor unit.
- Table 6: Heat Pump Only Heating Mode: Details airflow for heat pump comfort and efficiency in high and low-speed operations.
- Table 7: Electric Heating Modes: Lists airflow for electric heating across various kW ranges.
- Table 8: Minimum CFM for Electric Heater Application: Specifies minimum acceptable airflows for electric heater installations.
Capacities and Corrections
- Table 9: Cooling Capacities (MBtuh): Presents cooling capacities at different saturated evaporator leaving temperatures and airflow rates.
- Table 10: Estimated Sound Power Level of Airflow from Duct (dB): Provides sound power levels across octave bands for various conditions.
- Table 11: Airflow Performance Correction Factors: Details static pressure correction factors based on heater elements and sizes.
- Table 12: Air Delivery Performance Correction Component Pressure Drop: Shows pressure drop corrections for dry-to-wet coil conditions at indicated airflows.
- Table 13: Factory-Installed Filter Static Pressure Drop: Lists static pressure drop across factory filters for different unit sizes and airflows.
Electrical and Heater Data
- Table 14: Units without Electrical Heat: Provides motor HP, voltage, FLA, MCA, MOCP, and branch circuit wire size information for units without electric heat.
- Table 15: Electric Heaters: Lists heater part numbers, kW ratings, stages, internal circuit protection, fan coil size compatibility, and intelligent heat capability.
- Table 16: Electric Heater Internal Protection: Details fuses and circuit breaker quantities and sizes for electric heaters.
- Table 17: Electric Heater Electrical Data: Provides comprehensive electrical data for heaters, including amps, ampacity, wire sizing, and fuse/breaker requirements for various configurations.
- Table 18: Field Multipoint Wiring: Outlines wiring configurations for 24- and 30-kW single-phase electric heaters.
Acceptable Duct Conditions
For optimal operation, particularly for maintaining a dry secondary trap, fan coils must be installed with duct systems falling within the 'Acceptable Range' depicted in performance charts. These charts illustrate nominal airflow delivery versus duct system static pressure drop for heating and cooling modes. Cooling mode is shown with solid vertical lines, and heating mode with dashed vertical lines. Dotted curves represent static pressure drop characteristics for fixed duct systems, aiding in predicting system static pressure at any airflow based on a known point.
For example, a duct system designed for a 0.15 in. W.C. drop at 1200 CFM would result in the FT5 (036 size) delivering 1050 CFM with a 0.11 in. W.C. drop in cooling mode (Point 1). In heating mode, it would deliver 945 CFM with a 0.09 in. W.C. drop (Point 2). The FT5 can deliver these airflows against significantly higher static pressures.
Accessories
A range of accessories are available to enhance functionality and installation:
- Disconnect Kit: For safely disconnecting electrical power.
- Downflow Base Kit: Provides required clearance for downflow installations.
- Downflow Conversion Kit: Ensures proper condensate drainage and coil support for downflow applications.
- Downflow/Horizontal Conversion Gasket Kit: Provides proper gasketing for downflow or horizontal installations.
- Horizontal Water Management Kit: For installations with high static pressure and high relative humidity.
- Single-Point Wiring Kit: Simplifies wiring for units with 15- and 20-kW fused heaters.
- Filters: Collect dust particles to maintain coil cleanliness and system efficiency.
- Fan Coil Filter Cabinet: Houses filter media for particle removal.
- Infinity Series Air Purifier: Captures and kills airborne contaminants.
- Condensate Drain Trap Kit: Ensures proper condensate flow.
- Door Gasket Kit: Improves sealing to limit air leakage.
- Accessory Quick Connect Kit: Facilitates easy connection of IAQ accessories.
Warranty
The FT5 comes with a default 5-year parts limited warranty, which includes the compressor and coil. A 10-year parts limited warranty is available with timely registration. Equipment must be registered within 90 days of original installation, unless local laws dictate otherwise. This warranty applies to the original purchaser/homeowner and is not transferable to subsequent owners, except where laws mandate.