Anslut Counter Lighting LED
This document provides instructions for the Anslut Counter Lighting LED.
Safety Instructions
- Only intended for indoor use.
- Do not connect the light to the mains while it is still in the pack.
- Check that all electrical and connecting cables comply with applicable regulations and are connected according to the instructions.
- Never overload the mains; this can result in fire or electric shock.
- Keep out of reach of children.
- Do not store the light in damp, very cold, or very hot places, as this can damage the electronics.
- The electronics are sensitive to knocks and blows; avoid dropping the light.
- Never attempt to replace damaged power cords yourself.
- The product is not dimmable.
- Ensure that no concealed cables are damaged during installation.
- The LED light source is not replaceable; when it reaches the end of its life, the entire product must be replaced.
- To reduce the risk of strangulation, the flexible wiring connected to this luminaire must be effectively fixed to the wall if the wiring is within arm's reach.
- Maximum number of interconnected units: 9.
Warning!
New installations and extensions to existing systems should always be carried out by an authorized electrician. If you have the necessary experience and knowledge, you can replace power switches, wall sockets, fit plugs, extension cords, and light sockets. Otherwise, contact an electrician. Incorrect installation can result in fatal injury and the risk of fire.
Symbols
- CE: Approved as per applicable directives.
- Indoor use only symbol.
- Safety class II symbol.
- Recycle discarded product in accordance with local regulations symbol.
Technical Data
- Rated voltage: 230 V ~ 50 Hz
- Output: 11 W
- Luminous flux: 1250 lm
- Colour temperature: 3000 K
- Life span: 35000 h
- Off/On cycles: 20000 times
- Energy class: E
- Dimmable: No
- Protection rating: IP20
- Diffusion angle: 130°
- Luminous flux retention factor: 0.9
Installation
See figures for installation instructions:
FIG. 1
FIG. 2
FIG. 3
FIG. 4
FIG. 5
FIG. 6
FIG. 7
Product Information Sheet
- Supplier's name or trademark: Anslut
- Supplier's address: Jula AB, Julagatan, SE-532 24 Skara
- Model identifier: 019936
- Type of light source: LED
- Lighting technology used: LED
- Non-directional or directional: NDLS
- Light source connected to mains supply or light source not connected to mains supply: MLS
- Connected light source (CLS): No
- Colour-tuneable light source: No
- Envelope: No
- High luminance light source: No
- Anti-glare shield: No
- Dimmable: No
- Parameter: Energy consumption in on-mode (kWh/1000 h) | Value: 11
- Parameter: Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°) | Value: 1250 in Sphere (360°)
- Parameter: On-mode power (P), expressed in W | Value: 11.0
- Parameter: Networked standby power (Pnet) for CLS, expressed in W and rounded to the second decimal | Value: 0.00
- Parameter: Colour rendering index, rounded to the nearest integer, or the range of CRI-values that can be set | Value: 80
- Parameter: Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre) - Height | Value: 912
- Parameter: Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre) - Width | Value: 24
- Parameter: Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre) - Depth | Value: 34
- Parameter: Claim of equivalent power (c) | Value: 0.434
- Parameter: Chromaticity coordinates (x and y) | Value: 0.403
- Parameters for directional light sources: Peak luminous intensity (cd) | Value: -
- Parameters for directional light sources: Beam angle in degrees, or the range of beam angles that can be set | Value: -
- Parameters for LED and OLED light sources: R9 colour rendering index value | Value: 0
- Parameters for LED and OLED light sources: The lumen maintenance factor | Value: 0.96
- Parameters for LED and OLED mains light sources: Displacement factor (cos φ1) | Value: 0.70
- Parameters for LED and OLED mains light sources: Claims that an LED light source replaces a fluorescent light source without integrated ballast of a particular wattage. (b) | Value: -
- Parameters for LED and OLED mains light sources: Flicker metric (Pst LM) | Value: 1.0
- Parameter: Energy efficiency class | Value: E
- Parameter: Correlated colour temperature, rounded to the nearest 100 K, or the range of correlated colour temperatures, rounded to the nearest 100 K, that can be set | Value: 3000
- Parameter: Standby power (P♭), expressed in W and rounded to the second decimal | Value: 0.00
- Parameter: Spectral power distribution in the range 250 nm to 800 nm, at full-load | Value: See image in last page
- Parameter: If yes, equivalent power (W) | Value: -
- Parameter: Survival factor | Value: 0.90
- Parameter: Colour consistency in mcadam ellipses | Value: 6
- Parameter: If yes then replacement claim (W) | Value: -
- Parameter: Stroboscopic effect metric (SVM) | Value: 0.4