Legrand Green'up Home Connected Charging Stations for Electric Vehicles
References: 0 570 01/02/03/04/07, 0 570 21/22/30/31/32/35/37, GUH057003 - GUH057030
1. Usage
The Green'up Home electric vehicle charging station allows charging in Mode 3 or Mode 2 + Mode 3. It is natively connected to the Home + Control App and enables:
- Remote charging control (Start and Stop)
- Charging schedule programming (by day/hour)
- Electricity consumption monitoring (real-time and historical)
- Receiving status change notifications
Connection to the domestic Internet network is possible via RJ45 cable or Wi-Fi. In the case of Wi-Fi, automatic firmware updates for the station will occur. A Bluetooth connection with a smartphone with network access allows for manual firmware updates.
It is suitable for residential or small tertiary use and can be installed indoors or outdoors, directly on the wall or on a metal stand (ref. 0 570 57) alone or back-to-back.
2. Product Range
2.1 References
The charging stations are designed for electric vehicles and comply with the following standards:
- IEC 61851-1: Product standard for conductive charging systems for electric vehicles
- NF C 15-100: Low voltage electrical installation standard
- UTE C 17-722 guide: Electric or hybrid vehicle charging supply installations via socket outlets
- IEC 60364-7-722: Requirements for electrical installations and locations for electric vehicles
Conformity: EV Ready 2.0, REACH, RoHS. RED: ETSI EN 300 328-V2.2.2: 2019.
2.2 Delivery Status
Reference | Delivered Protection | Pre-assembled Glands |
---|---|---|
0 570 03 - GUH057003 | Yes | 4-entry gland ISO 32 |
0 570 30 - GUH057030 | No* | 4-entry gland ISO 32 + ISO 25 cable gland (not fitted) |
0 570 01/04 | Yes | 4-entry gland ISO 32 + ISO 32 gland, to be fitted + ISO 25 cable gland |
0 570 21/31/35 | No* | 4-entry gland ISO 32 + ISO 25 cable gland (not fitted) |
0 570 02/07 | Yes | 4-entry gland ISO 32 |
0 570 22/32/37 | No* | 4-entry gland ISO 32 + ISO 32 gland, to be fitted + ISO 25 cable gland |
* See page 2 for recommended protection to install.
Details of the sockets:
- For Mode 3 charging: Type T2s socket (single-phase or three-phase depending on version) equipped with a locking system with pilot contacts conforming to IEC62196-1 and IEC 62196-2. Only use a manufacturer-approved plug with silver-plated contacts.
- For Mode 2 charging: Domestic Type E or F socket 2P+T (16A 250V 16A VE) with magnetic presence detection for Green'up plug conforming to NF C 61-314 and IEC 60884-1. The use of extension cords and adapters is prohibited.
Details of the indicators:
An LED bar is visible on the front panel for reporting the charging station's status:
- Green: ready for charging
- Blue: charging in progress
- Red: fault
The intensity and operating mode of the LEDs are customizable in the Home + Control App. For example, the LEDs can be turned off when the station is not in use.
3. Technical Specifications
3.1 Mechanical Characteristics
- Impact resistance: IK 10
- Solid/liquid ingress protection: IP 55
- Plug engaged Mode 3 socket: IP55
- Plug engaged Mode 2 socket: IP54
3.2 Material Characteristics
- Station color: Two-tone RAL 7016 + RAL 9005
- Front panel: Polycarbonate RAL 7016
- Cover: Polycarbonate - RAL 9005
- Base: Polycarbonate - RAL 7016
- Fixing plate: 20/10 INOX 304L steel sheet
- Stand: DC01 steel - Primary coating + RAL 7016 paint
- Glow wire resistance: conforms to IEC 61439-1, clause 10.2.3.2.1
3.3 Electrical Characteristics
Stations | Ph + N | 3 Ph + N | |
---|---|---|---|
Operating voltage (Ue) determined at 20°C | 230 V~ | 400 V~ | |
Impulse withstand voltage (Uimp) | 4 kV | ||
Insulation voltage (Ui) | 230 V | 500 V | |
Frequency (fn) | 50 Hz/60 Hz | ||
Rated voltage | 230 V | 400 V | |
Tolerance of simple voltage (V) (excluding vehicle requirements) | 195V-265V | ||
Conditional short-circuit current | 4.5kA/6kA/10kA depending on upstream protection device | ||
Thermal stress limit in C/C | 16,000 A²s | ||
Neutral system compatibility: TNS, TT. | In case of IT neutral system, it is possible to locally change the neutral system by adding an isolation transformer. Integrated differential protection: 6mA DC fault current detection. Overcurrent detection function. |
3.4 Charging Station Communication Operation
Connected Mode (automatic firmware update)
Wi-Fi Technology: 2.4 GHz, range 100m in open field. Residential and private Wi-Fi type, type A BGN (not compatible with open Hotspot networks) or via Ethernet cable category 5 F/UTP minimum, maximum length 100 m.
Non-connected Mode
Bluetooth BLE: range 10 m in open field. Updating the station in this configuration (station not connected) requires at least access to a 4G/5G, Wi-Fi or IP connection with the smartphone.
3.5 Electromagnetic Compatibility
- General classification of disturbances: IEC 61000-6-1 and IEC 61000-6-3 criterion A
- EMC: IEC 61851-21-2
- Immunity to electrostatic discharges (IEC 61000-4-2): ± 8kV in air / ± 4kV contact criterion B
- Immunity to fast transients (IEC 61000-4-4): ± 2kV on control / ±4kV on power criterion A
- Immunity to surges (IEC 61000-4-5): ±2kV differential mode criterion A on power, ±4kV common mode criterion A on power, ±1kV coupling clamp criterion A on control
- Immunity to magnetic fields (IEC 61000-4-8): 100A/m
- Immunity to voltage dips (IEC 61000-4-11/IEC 61000-4-34): 0% residual voltage for 250/300 cycles at 50/60Hz criterion C, 0% residual voltage for 1 cycle at 50/60Hz criterion B, 70% residual voltage for 25/30 cycles at 50/60Hz criterion B, 40% residual voltage for 10/12 cycles at 50/60Hz criterion B.
- Immunity to short interruptions: IEC 61851-21-2
- Immunity to conducted disturbances: IEC 61000-4-6: 10V/m from 0.15 MHz to 80MHz, 80% AM - 1KHz criterion A, ETSI301489-1; 3V/m criterion A
- Immunity to the vehicle's ground measurement signal (ZOE type): Peak 1.5 to 2ms 20mA peak for 30s in C1 state according to IEC 61851-1 (ZE READY specification)
- Immunity to radiated electromagnetic fields at radio frequencies: IEC 61000-4-3: 10V/m from 80 MHz to 6 GHz criterion A, ETSI301489-1: 3V/m criterion A
3.6 Climatic Characteristics
- Operating temperature: -30° C to + 50° C
- Storage temperature: -25° C to + 70° C
- Indoor or outdoor installation
- UV resistant according to Test ISO 4892-2 weatherometer 750 h Method A
4. Connection
Some stations are supplied with the necessary protection to meet regulatory installation requirements. Below are the recommended protections to install for versions supplied without protection:
- Protection for Type E or F socket: integrated in all stations with this type of socket.
- Prescribed upstream differential protection: 30mA Type A or F for single-phase stations (1 phase + N), 30mA Type F for three-phase stations (3 phases + N). Or according to local regulations, 30mA Type F for all stations.
- Prescribed overcurrent protection: for charging station set to 16A: 20A circuit breaker curve C, for charging station set to 20A: 25A circuit breaker curve C, for charging station set to 25A: 32A circuit breaker curve C, for charging station set to 32A: 40A circuit breaker curve C.
- Voltage release: 12V to 48 V.
Safety control (outgoing signal): via a 12V= pulsed signal controlling a voltage release ref. 4 062 76 on the upstream protection device.
External control (incoming signal): via a dry contact, 12V contact voltage, authorizing charging on the Hp/Hc terminal block (overrideable) or on the On/Off terminal block (not overrideable).
The station's stand can accommodate a junction box of maximum 130 x 130 mm or a Plexo³ 4-module box cover.
Sector connection:
Phase/Neutral/Ground on automatic terminals 2.5 to 10 mm² rigid H07 V/U or flexible H07 V K with ferrule. The charging station is permanently connected to the AC power supply network.
TIC connection:
The station is compatible with standard TIC and historical TIC with a maximum length of 100 m.
Ethernet network connection:
Connection possible via Ethernet cable category 5 F/UTP minimum, maximum length 100 m.
5. Dimensions and Weight
Mode 3
0 570 01: 4 kgs
0 570 21: 3.6 kgs
0 570 02: 3.9 kgs
0 570 22: 3.9 kgs
Mode 2 + Mode 3
0 570 03: 4.4 kgs
0 570 30: 4 kgs
0 570 04: 4.4 kgs
0 570 31: 4 kgs
0 570 07: 4.4 kgs
0 570 32: 4.4 kgs
0 570 35: 4 kgs
0 570 37: 4.4 kgs
6. Maintenance
Attention: For the use of specific cleaning products, a preliminary test is necessary.
Resistant to the following products: Ethanol 96%, Ethylene glycol, Fuel, Hexane, Engine oil 5W40, Ergacid 1% dilution, Ergagem 1% dilution, white spirit.
Superficial cleaning with soapy water, diluted ammonia, diluted bleach at 10%, glass cleaner, pre-impregnated wipes.
The maintenance plan is available in the installer guide.
7. Standards and Regulations
The charging stations for electric vehicles are designed in compliance with the standards:
- IEC 61851-1: product standard for conductive charging systems for electric vehicles
- NF C 15-100: low voltage electrical installation standard
- UTE C 17-722 guide: Electric or hybrid vehicle charging supply installations via socket outlets
- IEC 60364-7-722: Requirements for electrical installations and locations for electric vehicles
Conformity: EV Ready 2.0, REACH, RoHS. RED: ETSI EN 300 328-V2.2.2: 2019.
8. Other Information
Installer Guide: Mounting information, equipment, accessories, spare parts and maintenance plan available in the online catalog.
PEP File: available in the online catalog.
Related Documents
![]() |
Legrand EV Charging Station Installation and Technical Guide Comprehensive guide for the installation, connection, and technical specifications of Legrand EV charging stations. Covers electrical connections, calibration, signal wiring, and safety instructions. |
![]() |
Legrand Green'up Access EV Charging Solutions Information on Legrand Green'up Access kits and sockets for electric vehicle charging, including installation principles and product specifications. |
![]() |
Legrand Green'up Access IP55 Electric Vehicle Charging Socket Installation Guide Comprehensive guide for installing the Legrand Green'up Access IP55 electric vehicle charging socket. Covers safety instructions, installation steps, and technical specifications for Mode 1 and Mode 2 charging. |
![]() |
Legrand Green'up Access Safety Socket for Electric Vehicle Charging Detailed information on the Legrand Green'up Access safety socket for charging electric vehicles in modes 1 and 2. Includes installation instructions, technical specifications, and safety guidelines. |
![]() |
Legrand EV Charging Station User Guide Comprehensive user guide for the Legrand EV Charging Station (models 0 570 10 to 0 570 17), covering features, safety, intended use, user interfaces, charging modes, load management, maintenance, app control, and troubleshooting. |
![]() |
Legrand 20A EV Charger Wall Socket Discover the Legrand 20A EV Charger Wall Socket, offering fast and reliable electric vehicle charging stability. Suitable for residential applications, this energy-efficient socket is part of the Excel Life range. |
![]() |
Legrand Module Control with Netatmo (Gateway) - Technical Specifications and Installation Guide Comprehensive guide to the Legrand Module Control with Netatmo, detailing its technical specifications, electrical and mechanical characteristics, installation, configuration, and compliance with standards. This smart home gateway connects devices via Wi-Fi and RF. |
![]() |
Legrand Wireless 4 Scenes Control CB0414 - Installation and Usage Guide Install, reset, and use the Legrand Wireless 4 Scenes Control (CB0414) with the Home + Control app. Includes safety instructions, technical specifications, and EU declaration of conformity. |