I. Overview

This product is a wireless Internet of Things monitor, providing real-time monitoring, alarm, data recording, data uploading, and large screen display of temperature and humidity. Integrated with the "Elitech iCold" platform and APP, it enables functions like remote data viewing, historical data query, remote alarm push, and equipment GPS positioning (4G version only). It is widely used in the food, medicine, catering, international warehousing, and logistics industries.

1. Features

2. Interface

4G Version Interface:

Note: When temperature and humidity exceed upper limits, values are in red; below lower limits, values are in blue.

WIFI Version Interface: (Similar to 4G version, without GPS icon)

Device Components:

Figure: Gel bottle Sensor

Figure: The Aircraft Interface

3. Model Selection List

Probe TypeBuilt-inExternal
Channel1 temperature probe and 1 humidity probeOne temperature probe1 temperature probe and 1 humidity probe2 temperature probes and 2 humidity probesTwo temperature probesOne temperature probes
Measuring rangeTemperature: -20~60°C Humidity: 0~100%RHTemperature: -40~80°C Humidity: 0~100%RHTemperature: -20~60°CTemperature: -40~80°CTemperature (Normal): -40~80°C Temperature (Ultralow): -196~150°C
Sensor typeDigital temperature and humidity sensor, Digital temperature sensor, Gel bottle temperature sensor using aircraft head interface, Ultra low temperature sensor using aircraft head interface
Measurement accuracy(Normal) Temperature: ±0.5°C Humidity: ±5%RH (Ultralow) ±0.3°C(-20°C~40°C), ±0.5°C (-50°C~85°C), ±1°C(-100°C~150°C), ±2°C (Others)

Note: The specific sensor type is subject to the actual product.

II. Technical Parameters

  1. Power input: 5V/2A (DC)
  2. Temperature display resolution: 0.1°C
  3. Humidity display resolution: 0.1%RH
  4. Number of offline recording groups: 100,000
  5. Data storage mode: Circular storage
  6. Record, upload interval and alarm interval:
    • Normal recording interval: 1min~24H
    • Alarm recording interval: 1min~24H (must be less than or equal to normal recording interval)
    • Normal upload interval: 1min~24H, default 5min (must be greater than or equal to normal recording interval)
    • Alarm upload interval: 1min~24H, default 2min (must be greater than or equal to alarm upload recording interval)
  7. Battery life:
    • Not less than 3 months (@25°C, upload interval: 30min, LBS positioning, 4G version)
    • Not less than 14 days (@25°C, upload interval: 30min, LBS+GPS positioning, 4G version)
    • Not less than 4 months (@25°C, upload interval: 30min, WIFI version)
  8. Indicator light: Alarm indicator, charging indicator.
  9. Screen: TFT color screen.
  10. Communication mode: 4G/WIFI.
  11. Alarm modes: Local alarm and cloud alarm.
  12. Buttons: Power on/off, start, menu, stop.
  13. Support Bluetooth printing.
  14. Support GPS and LBS positioning (4G version only).
  15. Waterproof grade: IP65 for built-in probe and IP64 for external probe.
  16. Specification and dimension: 109*69.4*22.9mm

III. Operation Instructions

1. Installing and removing the probe (Only aircraft head interface)

Align the aviation plug with the interface and insert it. Turn the screw clockwise to fix the probe. To disassemble, turn the screw counterclockwise and pull out the probe.

[Image: Illustration showing probe installation and removal]

2. Charging

Connect to the power adapter via USB cable. The charging indicator flashes during charging and is always on when fully charged.

3. Power on/off

Press and hold the power on/off button for 3 seconds to turn the device on/off. The device cannot be turned off while recording.

4. Start recording

When the equipment is in an unmonitored running state, press the "Start" button for 3 seconds. In the pop-up box, click "Yes" to start, then click the "Menu" button to confirm.

[Image: Device screen showing "Start recording? Yes/No" prompt]

5. Stop recording

When the equipment is in a monitored running state, press the "Stop" button for 3 seconds. In the pop-up box, click "Yes" to stop, then click the "Menu" button to confirm.

[Image: Device screen showing "Stop recording? Yes/No" prompt]

6. Maximum, Minimum, Average View

Click the "Menu" button to enter the maximum, minimum, and average display page.

[Image: Device screen displaying MAX, MIN, AVG temperature and humidity values]

7. Menu

Press the "Menu" button for 3 seconds to enter the main menu. Button functions:

Menu Options:

[Image: Menu screen showing options like Bluetooth Print, Display Settings, Configuration, Device Information, WIFI Config]

[Image: Configuration screen showing settings for recording and upload intervals, buzzer alarm, etc.]

[Image: Device Information screen showing device name, GUID, etc.]

4. Print data

Ensure the Bluetooth printer is connected. Select "Bluetooth printing" from the menu to enter the printing interface. Wait for the printer to connect, then select data to print.

[Image: Bluetooth Print screen showing connection status and print options]

IV. Elitech iCold Platform

Please scan the QR code on the cover or search for "Elitech iCold" in the App Store or Google Play to download the Elitech App.

1. APP Login

[Image: App screens showing login, registration, and adding a device]

WiFi network configuration (Only WiFi Version):

  1. Connect your mobile phone to your preferred WiFi/WLAN network.
  2. Turn on the device. Navigate to "WIFI config" via the Menu, select "smartlink mode", and confirm. Wait for the "[Wi-Fi icon]" icon to appear.
  3. Follow the "Add Device" steps. The APP will prompt for Wi-Fi configuration. Click "OK" to proceed if the device is not connected, or "CANCEL" otherwise.
  4. Configure the Wi-Fi network by entering the password. The "[Wi-Fi icon]" icon will appear upon successful configuration. If timed out, verify the Wi-Fi password and reconfigure.
  5. To reconfigure Wi-Fi, repeat steps 1 and 2. Then, go to "Device Information" on the APP, click the "[Wi-Fi icon]" icon, and follow steps 2-4.

[Image: App screens showing Wi-Fi configuration steps]

3. Device Management

After the device starts recording and is added to the platform, wait for data upload to display online. Refer to III-3 for starting recording.

To make further configurations (e.g., historical data, temperature unit, alarm limits, upload intervals), enter the device information page.

Note: If the device temperature unit is changed, it must also be changed in user settings (More-Setting).

[Image: App screens showing Online Data, Historical Data, Configurations, and Temperature Unit settings]

VII. Elitech iCold Platform

For more functions, please visit the Elitech iCold Platform: new.i-elitech.com.

VIII. Top-up

Free data and advanced platform service are activated upon the first registration. After the probation period, customers need to recharge the device by referring to the operation manual.

Models: RCW-360 Plus 4G WiFi Wireless Temperature, RCW-360, RCW-360 Wireless Temperature, Plus 4G WiFi Wireless Temperature, WiFi Wireless Temperature, Plus 4G Wireless Temperature, Wireless Temperature, Temperature

PDF preview unavailable. Download the PDF instead.

Elitech RCW-360 Plus 4G WiFi IoT Temperature Data Logger User Manual Adobe PDF library 10.01 Adobe Illustrator(R) 16.0

Related Documents

Preview Elitech RCW-360 2G/4G/WIFI User Manual - Temperature & Humidity Data Logger
User manual for the Elitech RCW-360 series data logger, covering setup, operation, Elitech app integration, cloud services, and technical specifications for temperature and humidity monitoring.
Preview Elitech IoT & Cold Chain Data Loggers | Comprehensive Product Catalog
Explore Elitech's extensive range of IoT and cold chain data loggers, including temperature, humidity, and multi-use devices. Discover features, technical specifications, and software solutions for reliable monitoring and compliance.
Preview Elitech RCW-360 Pro 4G/WiFi User Manual - Temperature & Humidity Monitoring
Comprehensive user manual for the Elitech RCW-360 Pro 4G/WiFi wireless temperature and humidity data logger. Learn about features, interface, technical parameters, operation instructions, and Elitech iCold platform usage.
Preview Elitech RCW-5i Single-Use IoT Data Logger User Manual
User manual for the Elitech RCW-5i single-use IoT data logger, detailing its product presentation, technical specifications, selection table, operation instructions, data export, LED indicator meanings, LCD display declarations, and safety precautions.
Preview Elitech RCW-360 Plus IoT Data Loggers: Temperature & Humidity Monitoring
Discover the Elitech RCW-360 Plus IoT Data Loggers for precise temperature and humidity monitoring. Features include real-time data upload, cloud platform access, HACCP compliance, and advanced alarm notifications for logistics and food safety.
Preview Elitech RCW-360 WIFI User Manual - Temperature and Humidity Data Logger
User manual for the Elitech RCW-360 WIFI, a real-time temperature and humidity data logger. Features include WiFi connectivity, cloud access, technical specifications, and setup instructions.
Preview Elitech RCW-360 2G/4G/WIFI User Manual
User manual for the Elitech RCW-360, a 2G/4G/WIFI temperature and humidity data logger. Covers device appearance, charging, power operations, app setup, WiFi configuration, cloud access, and technical specifications.
Preview Elitech RCW-3000/3200 Data Logger and Transceiver Monitor System User Manual
User manual for the Elitech RCW-3000/3200 split network monitoring system, detailing product overview, features, structure, display interface, technical parameters, and operation instructions for data logging and transceiver monitoring.