HEAT PUMP WATER HEATER FOR WALL MOUNTING AND FLOOR-STANDING INSTALLATION WITH NEGATIVE AIR TEMPERATURES
Product Visual Description
The EGEA TECH LT units are presented in a clean, modern design, typically white with contrasting black elements. The product images showcase the wall-mounted and floor-standing configurations, highlighting the integrated nature of the heat pump and storage tank. A separate visual depicts the intuitive touch control panel on the unit and a smartphone interface displaying the 'FERROLI HOME' app, illustrating the connectivity features.
APPLICATIONS
The air can be ducted both in and out to convey the flow appropriately in different situations. Suitable for using energy present outside.
GENERAL FEATURES
- Air heat pump and integrated storage tank for DHW (Domestic Hot Water) production.
- Active defrosting system for operation down to -7°C air temperature.
- Uses R290 ecological gas for models 90-120 and R134a for models 200-260.
- Possibility of ducting expelled air.
- Wall mounting available for model 90-120; floor-standing installation for models 200-260.
- Support heating element: 1500 W (floor-standing models) / 1200 W (wall-mounted models).
- Available operating modes: Eco, Auto, Boost, Electric, Fan.
- Wi-Fi card installed as standard, enabling control via smartphone using the "FERROLI HOME" App.
- Simple and intuitive touch control panel on board the machine.
- Enameled steel water storage tank with 50 mm polyurethane insulation.
- Aluminum main heat exchanger located outside the tank.
- Arrangement for solar coil (version "LT-S").
- Double anti-corrosion magnesium anode (model 200-260).
- Programmable anti-legionella cycle.
- Digital input for activation based on photovoltaic energy availability.
- Digital input for activation based on reduced electricity rates.
- Digital input for combination with solar thermal systems (models "LT-S").
- Integrated management of forced circulation solar thermal systems (models "LT-S").
CONTROL SYSTEM AND MODES
The intuitive programmable control system allows selection of various operating modes:
- Eco: Heat pump only (Max setpoint 62°C).
- Auto: Heat pump with heating element for support (Max setpoint 62°C).
- Boost: Heat pump and heating element simultaneously (Max setpoint 75°C).
- Electric: Heating element only (Max setpoint 75°C).
- Fan: Active ventilation only.
The EGEA TECH electronics can manage and optimize integration with other energy sources:
- Deactivating the heat pump if solar thermal energy is available (models LT-S).
- Activating and exploiting photovoltaic overproduction by raising water temperature up to a user-set value (max 75°C).
- LT-S models can be combined with solar thermal systems, managed either by their own control unit or directly by the EGEA TECH electronics.
CONNECTIVITY
Thanks to the "FERROLI HOME" App, downloadable on smartphone, EGEA TECH can be fully managed by changing its parameters and operating modes. [? Ferroli Home App interface]
Available on [? App Store] and [? Google Play].
OPERATING LIMITS
Temperature range for guaranteed correct operation:
Model 90-120 LT
Model 200-260 LT / LT-S
[Graph description: The graph illustrates operating limits based on inlet air temperature (°C) on the x-axis and the temperature of hot water produced (°C) on the y-axis. For model 90-120 LT, the heat pump operates effectively between -5°C and 43°C air temperature, producing hot water up to 62°C. The integration with the heating element extends the maximum hot water temperature to 75°C. For model 200-260 LT/LT-S, the heat pump operates between -7°C and 43°C air temperature, producing hot water up to 62°C. The heating element integration allows for hot water temperatures up to 75°C.]
A: Inlet air temperature (°C)
B: Temperature of hot water produced (°C)
Working range for heat pump
Integration with heating element only
SUPPLY VOLTAGE RANGE
Allowed variation conditions for the power supply:
- Standard power supply: 230-1-50 V-ph-Hz
- Permissible voltage range: 207-254 V
GENERAL TECHNICAL DATA
Feature | Unit | 90 LT | 120 LT | 200 LT | 260 LT | 200 LT-S | 260 LT-S |
---|---|---|---|---|---|---|---|
Nominal storage capacity | L | 89 | 118 | 192 | 250 | 187 | 247 |
Max. hot water capacity at 40°C | L | 102 | 145 | 247 | 340 | 241 | 335 |
Storage dispersion | W | 40 | 46 | 60 | 70 | 60 | 70 |
DHW max. temperature (heat pump only) | °C | 62 | 62 | 62 | 62 | 62 | 62 |
DHW max. temperature (supplementary booster) | °C | 75 | 75 | 75 | 75 | 75 | 75 |
Integrated heating element power | W | 1200 | 1200 | 1500 | 1500 | 1500 | 1500 |
Average absorbed power (heating) | W | 270 | 270 | 430 | 430 | 430 | 430 |
Pump heat output | W | 607 | 613 | 1339 | 1249 | 1339 | 1249 |
Dimensions (Ø x H) | mm | 510 x 1333 | 510 x 1555 | 621 x 1607 | 621 x 1892 | 621 x 1607 | 621 x 1892 |
Empty weight | kg | 49 | 55 | 88 | 100 | 97 | 109 |
Max. water pressure | bar | 7 | 7 | 7 | 7 | 7 | 7 |
Max. air temperature | °C | 43 | 43 | 43 | 43 | 43 | 43 |
Min. air temperature | °C | -5 | -5 | -7 | -7 | -7 | -7 |
Nominal air flow | m³/h | 170 | 170 | 450 | 450 | 450 | 450 |
Max. available head for cold air outlet | Pa | 110 | 110 | 117 | 117 | 117 | 117 |
Duct diameter | mm | 125 | 125 | 160 | 160 | 160 | 160 |
Required room volume | m³ | 15 | 15 | >20 | >20 | >20 | >20 |
Power supply parameters | V-Hz | 230V - 50Hz | 230V - 50Hz | 230V - 50Hz | 230V - 50Hz | 230V - 50Hz | 230V - 50Hz |
Protection rating | IP24 | IP24 | IP24 | IP24 | IP24 | IP24 | |
Indoor sound power Lw(A) | dB(A) | 54 | 53 | 53 | 51 | 53 | 51 |
Gas type | R290 | R290 | R134a | R134a | R134a | R134a | |
Charge quantity | g | 150 | 150 | 1000 | 1000 | 1000 | 1000 |
Heating time 7°C in ECO mode | hh:mm | 05:52* | 08:15* | 06:27* | 09:29* | 06:27* | 09:29* |
COP DHW 7°C | 3.12 | 2.75 | 3.23 | 3.37 | 3.23 | 3.37 | |
Internal coil for solar | -- | -- | -- | -- | 0.72 | 0.72 | |
Energy efficiency class (heating water, average conditions) | A+ | A+ | A+ | A+ | A+ | A+ | |
Energy efficiency of water heating (%) (average conditions) | % | 134 | 119 | 135 | 138 | 135 | 138 |
Annual energy consumption (average conditions) | kW/h | 383 | 430 | 761 | 1210 | 761 | 1210 |
Declared load profile | M | M | L | XL | L | XL | |
CODE | 2CP0020F | 2CP0021F | 2CP0024F | 2CP0025F | 2CP0026F | 2CP0027F |
* Test in accordance with EN16147-2017 with air inlet temperature at 7°C, boiler storage ambient temperature 20°C, water heating from 10°C to 53°C.
** Test in accordance with EN16147-2017 with air inlet temperature at 14°C, boiler storage ambient temperature 20°C, water heating from 10°C to 53°C.
ACCESSORIES
- CODE: 043007X0, DESCRIPTION: Solar collectors probe (for LT-S versions only)
- CODE: 2CP00280, DESCRIPTION: Cascade regulator kit (1 piece per water heater in cascade)
DIMENSIONS
Dimensional data for EGEA TECH models (in mm):
Model | A | B | C | D | E | F | G | H | I |
---|---|---|---|---|---|---|---|---|---|
90 LT | 1303 | 912 | 843 | 690 | 711 | - | - | - | - |
120 LT | 1555 | 1162 | 1094 | 940 | 963 | - | - | - | - |
200 LT | 1607 | 976 | 843 | 705 | 877 | 1142 | 705 | 1607 | 976 |
260 LT | 1892 | 1261 | 1094 | 785 | 1162 | 1427 | 735 | 1892 | 1261 |
200 LT-S | 1607 | 976 | 843 | 705 | 877 | 1142 | 705 | 1607 | 976 |
260 LT-S | 1892 | 1261 | 1094 | 785 | 1162 | 1427 | 735 | 1892 | 1261 |