Ferroli Solar Systems Catalog

Ferroli Solar Systems Catalog

Celebrating 70 years of Italian tradition since 1955.

Table of Contents

EcoHeat PRO Pressurized Solar Panels

Ferroli EcoHeat PRO are pressurized solar panels that operate by exchanging energy between the collector and the water in the reservoir. As the vacuum tubes absorb solar energy, the heatpipe transfers heat to the water in the reservoir. The liquid in the heatpipes turns into vapor, rises to the condenser, heat passes through the heat exchanger, and the vapors condense back into liquid, returning to the base of the heatpipe. This process continuously heats the cold water. The system is pressurized, supplying hot water under pressure without the need for a pump. It offers high efficiency due to an increased heat exchange surface area provided by the 18mm bulb heatpipe.

System Components:

  • Water reservoir
  • Heatpipe vacuum tube
  • Metal frame (support)
  • Support for vacuum tube
  • Side protection
  • Safety valve (6 bar)

Support:

  • Material: Stainless steel
  • Inclination angle: 30-45°

Optional Accessories:

  • Electric resistance (see page 10)

Vacuum Tube Composition:

  • Material: Extremely resistant borosilicate glass, copper heatpipe conductor.
  • Diameter: Ø 58 mm
  • Length: 1800 mm
  • Hail resistance: 25 mm
  • Thickness: 1.8 mm

Technical Specifications

Parameters Unit 12x1800 15x1800 20x1800
Total solar panel volume liters 120 150 200
Panel insulation thickness mm 50 50 50
Usable panel area sqm 1.50 1.88 2.5
Vacuum tube dimension mm 58x1800 58x1800 58x1800
Number of vacuum tubes 12 15 20
Panel weight kg 62.95 75.45 96.40

Diagram Description: Schematic of the EcoHeat PRO pressurized solar system. It shows a water reservoir connected to solar collectors via heatpipes. Key components include a 6-bar safety valve, an automatic air vent, a cold water inlet, and a connection to the consumer. The system operates with pressurized water, eliminating the need for a pump.

EcoSole Non-Pressurized Solar Panels

EcoSole non-pressurized solar panels for water heating rely on natural water circulation between the vacuum tubes and the water reservoir. As water in the vacuum tubes heats up, it naturally rises into the reservoir, while cooler water from the reservoir flows into the vacuum tubes, driving circulation throughout the system.

Reservoir:

  • Inner reservoir: SUS 304-2B (food-grade) stainless steel
  • Outer reservoir: Stainless steel
  • Insulation layer: Polyurethane foam
  • Heat retention: 72h

Vacuum Tube:

  • Material: Extremely resistant borosilicate glass.
  • Diameter: Ø58 mm
  • Length: 1800 mm
  • Hail resistance: 25 mm.
  • Thickness: 1.8 mm

Support:

  • Material: Stainless steel

Optional Accessories:

  • Electric resistance (see page 10)
  • Booster Pump (see page 9)

Technical Specifications

Parameters Unit 12x1800 15x1800 18x1800
Total solar panel volume liters 120 150 180
Panel insulation thickness mm 50 50 50
Usable panel area sqm 1.50 1.88 2.21
Vacuum tube dimension mm 58x1800 58x1800 58x1800
Number of vacuum tubes 12 15 18
Panel weight kg 58 78 86

Diagram Description: Schematic of the EcoSole non-pressurized solar system. It illustrates a water reservoir with a float and air vent, connected to vacuum tubes exposed to sunlight. Cold water enters the tubes, heats up, and rises naturally to the reservoir, creating a continuous circulation. The diagram shows the water flow path and key components like the reservoir, vacuum tubes, and support structure.

Ecotube NEW Evacuated Tube Solar Panels

Ecotube NEW are solar panels with heatpipe technology. They are available in three variants: Ecotube NEW 15 (15 vacuum tubes), Ecotube NEW 20 (20 vacuum tubes), and Ecotube NEW 25 (25 vacuum tubes). The selective coating on the inside of the vacuum tubes converts solar energy into thermal energy and transfers heat to the heatpipes via fins. The liquid in the heatpipes turns into vapor, rises to the condenser, heat passes through the heat exchanger, and the vapors condense back into liquid, returning to the base of the heatpipe. Heat is transferred to the heat transfer fluid (antifreeze or water) through the copper pipe. This heat transfer creates continuous circulation in the heatpipe as long as the collector is heated by the sun. Annual energy production in Wurzburg conditions is over 675 kWh/sqm.

Advantages:

  • No risk of freezing or bursting in winter (tubes do not contain water).
  • Compact structure, easily adaptable to mounting location.
  • Functions even if one or more tubes are broken.
  • Easy tube replacement.

Technical Specifications

Parameters Unit 15 20 25
Test pressure bar 10 10 10
Working pressure bar 4 4 4
Max. thermal agent temperature °C 280 280 280
Recommended thermal agent flow rate l/h 50-150 50-150 50-150
Thermal agent volume liters 1.15 1.15 1.15
Collector insulation thickness mm 40 40 40
Min/max inclination deg 20/70 from horizontal 20/70 from horizontal 20/70 from horizontal
Capture area sqm 2.06 2.74 3.36
Distance between tubes mm 78 78 78
Vacuum tube dimension mm 58x1800 58x1800 58x1800
Panel dimension mm 2020x1410x155 2020x1825x155 2020x2240x155
Number of vacuum tubes nr. 15 20 25
Panel weight kg 74 80 90

Ecotube NEW Solar Packages

These packages provide domestic hot water (DHW) production using Ecotube NEW evacuated tube solar panels. They are available in Basic and Comfort configurations for different household sizes.

Ecotube NEW - BASIC Package

For 2-3 People

Component Model/Description Qty
Solar Panels Ecotube NEW 20 TUBURI (includes mounting supports) 1
Boiler Wall-mounted boiler with 2 parallel serpentine coils ECOUNIT DW 150 1
Circulation Pump CRS25/6 - EAB 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C (10 KG) 1
Expansion Vessel VFN 24 liter for VFN systems 1

For 3-4 People

Component Model/Description Qty
Solar Panels Ecotube NEW 20 TUBURI (includes mounting supports) 1
Boiler Boiler with 2 serpentine coils ECOUNIT F 200-2C (with 1.5 kW resistance included) 1
Circulation Pump CRS25/6 - EAB 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C (10 KG) 1
Expansion Vessel VFN 24 liter for VFN systems 1

For 4-5 People

Component Model/Description Qty
Solar Panels Ecotube NEW 20 TUBURI (includes mounting supports) 2
Boiler Boiler with 2 serpentine coils ECOUNIT F 300-2C (with 1.5 kW resistance included) 1
Circulation Pump CRS25/6 - EAB 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C (10 KG) 2
Expansion Vessel VFN 24 liter for VFN systems 1

For 6-9 People

Component Model/Description Qty
Solar Panels Ecotube NEW 25 TUBURI (includes mounting supports) 2
Boiler Boiler with 2 serpentine coils ECOUNIT 500-2 WB 1
Circulation Pump CRS25/6 - EAB 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C (10 KG) 2
Expansion Vessel VFN 35 liter for VFN systems 1

Note: Packages do not include: thermostatic mixing valve kit, tap and automatic air vent kit, expansion vessel for boiler (VFN19, VFN24, VFN50 depending on boiler volume), copper or stainless steel pipe for connection from panel to boiler serpentine. Optional: An electric resistance kit with thermostat 3 kW or 4.5 kW can be mounted on the ECOUNIT-2C WB boiler.

Hydraulic Scheme: Solar Panels and Wall-Mounted Boiler for DHW Preparation

Diagram Description: Hydraulic schematic for preparing domestic hot water (a.c.m.) with solar panels and a wall-mounted boiler using an external boiler. It depicts the integration of solar collectors (Ecotube NEW), a hydraulic group (IDRO 12S Easy), an Ecotronic PRO controller, a boiler (ECOUNIT F 2C), an expansion vessel (VFN), safety valves, and sensors (S1, S2). The legend identifies S1 as the collector PT sensor and S2 as the boiler PT sensor.

Ecotube NEW - COMFORT Package

For 2-3 People

Component Model/Description Qty
Solar Panels Ecotube NEW 20 1
Boiler ECOUNIT WD 150-2C 1
Circulation Group IDRO 12S EASY 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C, 10 kg 1
Expansion Vessel VFN 35 liter 1

For 3-4 People

Component Model/Description Qty
Solar Panels Ecotube NEW 25 1
Boiler ECOUNIT F 200-2C (with 1.5/2 kW electric resistance included) 1
Circulation Group IDRO 12S EASY 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C, 10 kg 3
Expansion Vessel VFN 35 liter 1

For 4-5 People

Component Model/Description Qty
Solar Panels Ecotube NEW 20 2
Boiler ECOUNIT F 300-2C (with 1.5/2 kW electric resistance included) 1
Circulation Group IDRO 12S EASY 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C, 10 kg 3
Expansion Vessel VFN 50 liter 1

For 6-9 People

Component Model/Description Qty
Solar Panels Ecotube NEW 25 2
Boiler ECOUNIT WB 500-2C (with 2 kW electric resistance included) 1
Circulation Group IDRO 12S EASY 1
Control Panel ECOTRONIC PRO 1
Antifreeze Solar Antifreeze -30°C, 10 kg 3
Expansion Vessel VFN 50 liter 1

Note: Packages do not include: thermostatic mixing valve kit, tap and automatic air vent kit, expansion vessel for boiler (VFN19, VFN24, VFN50 depending on boiler volume), copper or stainless steel pipe for connection from panel to boiler serpentine. Optional: An electric resistance kit with thermostat 3 kW or 4.5 kW can be mounted on the ECOUNIT-2C WB boiler.

Hydraulic Scheme: Solar Panels and Wall-Mounted Boiler for DHW Preparation

Diagram Description: Hydraulic schematic for preparing domestic hot water (a.c.m.) with solar panels and a wall-mounted boiler using an external boiler. This diagram shows a different configuration involving a wall-mounted thermal unit (BlueHelix HiTech RRT H), a hydraulic group (IDRO 12S Easy), an Ecotronic PRO controller, a boiler (ECOUNIT F/HP 2C), an expansion vessel (VFN), safety valves, and sensors (S1, S2).

SOLAREVO V Flat Plate Solar Collectors

SOLAREVO V is a flat plate solar collector with forced circulation, offering high efficiency. It is certified by Keymark Solar (EN 12975), recognized as one of the most efficient solar collectors on the market (η=80%). Key features include a highly selective absorber surface made of aluminum with titanium oxide treatment, a robust frame supported by two aluminum bars for neat and versatile installation, a double-walled aluminum profile (2.4 mm) ensuring durability and enhanced insulation, and prismatic tempered glass with high transparency (3.2 mm thickness). The collector utilizes a high-performance absorber with a copper harp structure welded by laser and an ultra-selective surface of 0.5 mm. Integrated support accessories facilitate easy installation and universal compatibility. The collector is adjustable for various mounting types, including pitched or flat roofs, and uses Ø 22 mm fittings for compression connection/interconnection.

Mounting Options

Inclined Roof Mounting

Mounting Frame Code Fixing Supports Code
Complete mounting frame for 1 collector (*) 076239X0 Kit of 4 supports for tile mounting 076242X0
Complete mounting frame for 2 collectors (*) 076240X0 Kit of 4 universal consoles 076241X0

(*) For mounting multiple collectors in combination, use multiple kits.

Flat Roof Mounting

Mounting Frame Code Extension Kit Code
Base frame kit for 1 collector mod. 2.1 V 076235X0 Extension kit for each collector (mod. 2.1 V) - additional 076237X0
Base frame kit for 1 collector mod. 2.6 V 076236X0 Extension kit for each collector (mod. 2.6 V) - additional 076238X0

Hydraulic Accessories

Accessory Code Hydraulic Accessories Code
Thermostatic mixer connections 1/2" 013002X0 Hydraulic connections (interconnection set) (EXTENSION) 072292X0
Base hydraulic connections - set - first/last collector 072291X0 Automatic air vent 072293X0

Diagram Description: Diagrams illustrating mounting options for SOLAREVO V collectors on inclined and flat roofs, showing frame and support kits. Also includes hydraulic connection diagrams.

Technical Specifications and Pressure Drop

Model Unit V 2.1 V 2.6
Dimensions (LxHxD) mm 1230 x 1696 x 86 1230 x 2111 x 86
Gross area sqm 2.09 2.60
Effective area sqm 1.96 2.44
Weight (without fluid) kg 34.5 41.2
Closed circuit volume liters 1.6 1.8
Stagnation temperature °C 175.2 175.2
Absorber factor % 95 95
Emissivity factor % 4 4
Collector thermal insulation 40 mm high-density mineral wool
Heat transfer circuit fittings mm 22 22
Max. primary circuit operating pressure bar 10 10
Collector fittings nr. 4 4
Number of units per pallet nr. 12 12
CODE 0XGF1VWA 0XGF2VWA

Graph Description: Graph showing the pressure drop (delta p) in kPa versus volumetric flow rate (vdot) in l/h for SOLAREVO V collectors (models V 2.1 and V 2.6). The graph indicates that pressure loss increases with higher flow rates.

Solar System Accessories

Ecounit 2C WB / Ecounit 2C F Accumulation Boilers

Details on two-serpentine accumulation boilers, including technical specifications and diagrams with legends for connections.

Model Insulation (Polyurethane) Diameter Height Serpentine S1 Area Serpentine S2 Area Serpentine S1 Pressure Drop Serpentine S2 Pressure Drop Max. boiler/serpentine working temp. Electric Resistance Weight
mm mm mm sqm sqm mbar mbar °C kW kg
ECOUNIT-2C WB 150 rigid 455 1070 0.74 0.4 65 48 95/110 optional 65
500 moale 100 750 1710 1.8 1.2 210 90 95/110 optional 185
ECOUNIT-2C F 200 rigid 50 540 1453 0.5 0.83 155 254 95/110 1.5 73
620 1535 0.72 1.00 220 308 95/110 1.5 103

Diagram Description: Diagrams of Ecounit 2C WB and Ecounit 2C F boilers with legends indicating various connection points, sensors, and components like magnesium anodes and electric resistance.

Ecotronic Pro Electronic Controllers

Ecotronic Pro is specially designed for controlling pump speeds in high-efficiency solar and heating systems. It features two PWM outputs and an additional input for a Grundfos Direct Sensor™ VFD, enabling precise heat quantity measurement. Technical data includes 4 PT1000 temperature sensor inputs, 1 Grundfos Direct Sensor™ VFD input, 1 semiconductor relay output, 1 PWM output (512 Hz frequency, 10.5 V voltage), switching capacity up to 1(1) A at 100-240V, and total switching capacity of 1A at 240V. It operates on 100-240V, 50-60 Hz, with standby power consumption less than 1W. Functions include operation control, operating hour tachometer, speed regulation, drain-back option, and calorimeter. The housing is made of plastic (PC-ABS and PMMA) and can be wall-mounted or installed in a control panel. The display shows system status with 16-segment and 7-segment displays, plus 8 system status symbols. Control is via three front buttons. Protection type is IP 20 / EN 60529, protection class is I. Ambient temperature range is 0-40°C (32-104°F). Dimensions are 172 x 110 x 46 mm.

IDRO 12S Easy / IDRO 30 N Forced Circulation Groups

Characteristics: 3-speed circulation pump, installation filling/draining valve, thermometer, wall mounting kit, expanded polystyrene insulation, expansion vessel fixing ears, safety group with safety valve and manometer, and flow adjustment valve with visual indicator.

VFN Expansion Vessels

VFN are vertical expansion vessels designed for a maximum pressure of 10 bar. They are suitable for heating, cooling, potable water, and solar applications. Features include a fully welded body, an interchangeable high-quality rubber membrane compliant with DIN 4807-3, CE compliance for pressure vessels (97/23/CE, DIN EN 13881), maximum working temperature of 99°C, minimum working temperature of -10°C, continuous working temperature of 70°C, and a preset pressure of 2 bar.

MODEL Code Capacity (liters) Connections (C) Weight (kg) Diameter (mm) (D) Height (mm) (H) Preset Pressure (bar)
VFN 24 VFN0024 24 1" 3.26 250 430 2
VFN 35 VFN0035 35 1" 4.91 370 400 2
VFN 50 VFN0050 50 1" 7.65 370 695 2
VFN 80 VFN0080 80 1" 13.01 450 800 2

Booster - Automatic Pump

The Booster WG automatic pump is used to increase water pressure in non-pressurized solar panels. The pump rotor only works with domestic water. The pump operation can be adjusted using the switch: "O" - OFF, "I" - MANUAL Mode, "II" - AUTO Mode. It is primarily used to increase cold or hot water pressure for domestic use. Water temperature should not exceed 80°C during operation.

MODEL Max. Flow (L/min) Max. Head (m) Connection (")
15WG-120(A/R) 23 15 G3/4

Notes

Electric Heater

For pressurized/non-pressurized solar panels (EcoHeat/EcoSole models). Due to climatic changes, for example, when sunlight is weak, you can use the electric resistance to heat the water in the collector. If installing the electric resistance without connecting it to a controller, ensure it is equipped with a residual current device (overvoltage protection) for safe use. Remember to turn it off before showering. Washing or taking a bath with electrical appliances nearby is strictly prohibited.

Antifreeze -30°C

Antifreeze -30°C is intended for pressurized solar installations. Applications include improving heat transfer in radiators, air conditioning units, and heating, reducing friction by 45%, and providing flocculant, anti-limescale, anti-algae, and anti-freeze effects. To use, introduce it into the installation as is. For applications with a special freezing point, the product can be supplied upon request.

PDF preview unavailable. Download the PDF instead.

1752752536 Corel PDF Engine Version 16.1.0.843 CorelDRAW X6

Related Documents

Preview Catalog Ferroli: Boilere și Puffere pentru Încălzire Eficientă
Descoperiți gama completă de boilere electrice, termoelectrice și cu acumulare, precum și puffere Ferroli. Soluții fiabile și eficiente pentru apă caldă menajeră și sisteme de încălzire. Septembrie 2025.
Preview Ferroli EGEA TECH LT Heat Pump Water Heater - Features & Specifications
Discover the Ferroli EGEA TECH LT, an efficient heat pump water heater for wall and floor-standing installation, designed for negative air temperatures. Learn about its features, operating modes, connectivity, and technical specifications.
Preview Ferroli BOIPELLET PRO Pellet Boiler: Assembly and Exploitation Manual
Comprehensive assembly and operation manual for the Ferroli BOIPELLET PRO pellet boiler, covering safety instructions, technical specifications, installation, maintenance, and control panel functions.
Preview Ferroli BIOPELLET PRO: Cazane pe Peleți Eficiente pentru Încălzire Centrală
Descoperiți cazanul Ferroli BIOPELLET PRO, o soluție eficientă și automată pentru încălzire centrală. Cu randament ridicat, dimensiuni compacte și funcționare optimizată, ideal pentru locuințe.
Preview Ferroli FCP 20-V, 30-V, 40-V Wall-Mounted Fan Coil Installation and Operation Manual
Comprehensive guide for installing and operating Ferroli FCP series wall-mounted fan coil units (20-V, 30-V, 40-V). Covers general specifications, safety regulations, machine installation, electrical connections, wiring diagrams, unit positioning, wet connections, pipe insulation, condensation drainage, air venting, remote control usage, indicator lights, probe diagnostics, operating modes, timer programming, emergency key functions, and routine maintenance including filter and unit cleaning.
Preview Ferroli HE Programmer: User Instructions and Setup Guide
A comprehensive guide to setting up and operating the Ferroli HE Programmer for central heating and domestic hot water control. This manual covers time and day setting, pre-set programs, operating modes, detailed programming, and override functions.
Preview Ferroli ECOUNIT H 1B-2B: Installation, Maintenance, and Warranty Guide
Comprehensive guide for the Ferroli ECOUNIT H 1B-2B water heater and storage tanks, covering installation, commissioning, maintenance, technical specifications, and warranty information.
Preview Ferroli SFI00500R Stainless Steel Water Heater User Manual and Technical Data