Ferroli Solar Systems Catalog
Celebrating 70 years of Italian tradition since 1955.
Table of Contents
EcoHeat PRO Pressurized Solar Panels
Ferroli EcoHeat PRO are pressurized solar panels that operate by exchanging energy between the collector and the water in the reservoir. As the vacuum tubes absorb solar energy, the heatpipe transfers heat to the water in the reservoir. The liquid in the heatpipes turns into vapor, rises to the condenser, heat passes through the heat exchanger, and the vapors condense back into liquid, returning to the base of the heatpipe. This process continuously heats the cold water. The system is pressurized, supplying hot water under pressure without the need for a pump. It offers high efficiency due to an increased heat exchange surface area provided by the 18mm bulb heatpipe.
System Components:
- Water reservoir
- Heatpipe vacuum tube
- Metal frame (support)
- Support for vacuum tube
- Side protection
- Safety valve (6 bar)
Support:
- Material: Stainless steel
- Inclination angle: 30-45°
Optional Accessories:
- Electric resistance (see page 10)
Vacuum Tube Composition:
- Material: Extremely resistant borosilicate glass, copper heatpipe conductor.
- Diameter: Ø 58 mm
- Length: 1800 mm
- Hail resistance: 25 mm
- Thickness: 1.8 mm
Technical Specifications
Parameters | Unit | 12x1800 | 15x1800 | 20x1800 |
---|---|---|---|---|
Total solar panel volume | liters | 120 | 150 | 200 |
Panel insulation thickness | mm | 50 | 50 | 50 |
Usable panel area | sqm | 1.50 | 1.88 | 2.5 |
Vacuum tube dimension | mm | 58x1800 | 58x1800 | 58x1800 |
Number of vacuum tubes | 12 | 15 | 20 | |
Panel weight | kg | 62.95 | 75.45 | 96.40 |
Diagram Description: Schematic of the EcoHeat PRO pressurized solar system. It shows a water reservoir connected to solar collectors via heatpipes. Key components include a 6-bar safety valve, an automatic air vent, a cold water inlet, and a connection to the consumer. The system operates with pressurized water, eliminating the need for a pump.
EcoSole Non-Pressurized Solar Panels
EcoSole non-pressurized solar panels for water heating rely on natural water circulation between the vacuum tubes and the water reservoir. As water in the vacuum tubes heats up, it naturally rises into the reservoir, while cooler water from the reservoir flows into the vacuum tubes, driving circulation throughout the system.
Reservoir:
- Inner reservoir: SUS 304-2B (food-grade) stainless steel
- Outer reservoir: Stainless steel
- Insulation layer: Polyurethane foam
- Heat retention: 72h
Vacuum Tube:
- Material: Extremely resistant borosilicate glass.
- Diameter: Ø58 mm
- Length: 1800 mm
- Hail resistance: 25 mm.
- Thickness: 1.8 mm
Support:
- Material: Stainless steel
Optional Accessories:
- Electric resistance (see page 10)
- Booster Pump (see page 9)
Technical Specifications
Parameters | Unit | 12x1800 | 15x1800 | 18x1800 |
---|---|---|---|---|
Total solar panel volume | liters | 120 | 150 | 180 |
Panel insulation thickness | mm | 50 | 50 | 50 |
Usable panel area | sqm | 1.50 | 1.88 | 2.21 |
Vacuum tube dimension | mm | 58x1800 | 58x1800 | 58x1800 |
Number of vacuum tubes | 12 | 15 | 18 | |
Panel weight | kg | 58 | 78 | 86 |
Diagram Description: Schematic of the EcoSole non-pressurized solar system. It illustrates a water reservoir with a float and air vent, connected to vacuum tubes exposed to sunlight. Cold water enters the tubes, heats up, and rises naturally to the reservoir, creating a continuous circulation. The diagram shows the water flow path and key components like the reservoir, vacuum tubes, and support structure.
Ecotube NEW Evacuated Tube Solar Panels
Ecotube NEW are solar panels with heatpipe technology. They are available in three variants: Ecotube NEW 15 (15 vacuum tubes), Ecotube NEW 20 (20 vacuum tubes), and Ecotube NEW 25 (25 vacuum tubes). The selective coating on the inside of the vacuum tubes converts solar energy into thermal energy and transfers heat to the heatpipes via fins. The liquid in the heatpipes turns into vapor, rises to the condenser, heat passes through the heat exchanger, and the vapors condense back into liquid, returning to the base of the heatpipe. Heat is transferred to the heat transfer fluid (antifreeze or water) through the copper pipe. This heat transfer creates continuous circulation in the heatpipe as long as the collector is heated by the sun. Annual energy production in Wurzburg conditions is over 675 kWh/sqm.
Advantages:
- No risk of freezing or bursting in winter (tubes do not contain water).
- Compact structure, easily adaptable to mounting location.
- Functions even if one or more tubes are broken.
- Easy tube replacement.
Technical Specifications
Parameters | Unit | 15 | 20 | 25 |
---|---|---|---|---|
Test pressure | bar | 10 | 10 | 10 |
Working pressure | bar | 4 | 4 | 4 |
Max. thermal agent temperature | °C | 280 | 280 | 280 |
Recommended thermal agent flow rate | l/h | 50-150 | 50-150 | 50-150 |
Thermal agent volume | liters | 1.15 | 1.15 | 1.15 |
Collector insulation thickness | mm | 40 | 40 | 40 |
Min/max inclination | deg | 20/70 from horizontal | 20/70 from horizontal | 20/70 from horizontal |
Capture area | sqm | 2.06 | 2.74 | 3.36 |
Distance between tubes | mm | 78 | 78 | 78 |
Vacuum tube dimension | mm | 58x1800 | 58x1800 | 58x1800 |
Panel dimension | mm | 2020x1410x155 | 2020x1825x155 | 2020x2240x155 |
Number of vacuum tubes | nr. | 15 | 20 | 25 |
Panel weight | kg | 74 | 80 | 90 |
Ecotube NEW Solar Packages
These packages provide domestic hot water (DHW) production using Ecotube NEW evacuated tube solar panels. They are available in Basic and Comfort configurations for different household sizes.
Ecotube NEW - BASIC Package
For 2-3 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 20 TUBURI (includes mounting supports) | 1 |
Boiler | Wall-mounted boiler with 2 parallel serpentine coils ECOUNIT DW 150 | 1 |
Circulation Pump | CRS25/6 - EAB | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C (10 KG) | 1 |
Expansion Vessel | VFN 24 liter for VFN systems | 1 |
For 3-4 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 20 TUBURI (includes mounting supports) | 1 |
Boiler | Boiler with 2 serpentine coils ECOUNIT F 200-2C (with 1.5 kW resistance included) | 1 |
Circulation Pump | CRS25/6 - EAB | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C (10 KG) | 1 |
Expansion Vessel | VFN 24 liter for VFN systems | 1 |
For 4-5 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 20 TUBURI (includes mounting supports) | 2 |
Boiler | Boiler with 2 serpentine coils ECOUNIT F 300-2C (with 1.5 kW resistance included) | 1 |
Circulation Pump | CRS25/6 - EAB | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C (10 KG) | 2 |
Expansion Vessel | VFN 24 liter for VFN systems | 1 |
For 6-9 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 25 TUBURI (includes mounting supports) | 2 |
Boiler | Boiler with 2 serpentine coils ECOUNIT 500-2 WB | 1 |
Circulation Pump | CRS25/6 - EAB | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C (10 KG) | 2 |
Expansion Vessel | VFN 35 liter for VFN systems | 1 |
Note: Packages do not include: thermostatic mixing valve kit, tap and automatic air vent kit, expansion vessel for boiler (VFN19, VFN24, VFN50 depending on boiler volume), copper or stainless steel pipe for connection from panel to boiler serpentine. Optional: An electric resistance kit with thermostat 3 kW or 4.5 kW can be mounted on the ECOUNIT-2C WB boiler.
Hydraulic Scheme: Solar Panels and Wall-Mounted Boiler for DHW Preparation
Diagram Description: Hydraulic schematic for preparing domestic hot water (a.c.m.) with solar panels and a wall-mounted boiler using an external boiler. It depicts the integration of solar collectors (Ecotube NEW), a hydraulic group (IDRO 12S Easy), an Ecotronic PRO controller, a boiler (ECOUNIT F 2C), an expansion vessel (VFN), safety valves, and sensors (S1, S2). The legend identifies S1 as the collector PT sensor and S2 as the boiler PT sensor.
Ecotube NEW - COMFORT Package
For 2-3 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 20 | 1 |
Boiler | ECOUNIT WD 150-2C | 1 |
Circulation Group | IDRO 12S EASY | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C, 10 kg | 1 |
Expansion Vessel | VFN 35 liter | 1 |
For 3-4 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 25 | 1 |
Boiler | ECOUNIT F 200-2C (with 1.5/2 kW electric resistance included) | 1 |
Circulation Group | IDRO 12S EASY | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C, 10 kg | 3 |
Expansion Vessel | VFN 35 liter | 1 |
For 4-5 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 20 | 2 |
Boiler | ECOUNIT F 300-2C (with 1.5/2 kW electric resistance included) | 1 |
Circulation Group | IDRO 12S EASY | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C, 10 kg | 3 |
Expansion Vessel | VFN 50 liter | 1 |
For 6-9 People
Component | Model/Description | Qty |
---|---|---|
Solar Panels | Ecotube NEW 25 | 2 |
Boiler | ECOUNIT WB 500-2C (with 2 kW electric resistance included) | 1 |
Circulation Group | IDRO 12S EASY | 1 |
Control Panel | ECOTRONIC PRO | 1 |
Antifreeze | Solar Antifreeze -30°C, 10 kg | 3 |
Expansion Vessel | VFN 50 liter | 1 |
Note: Packages do not include: thermostatic mixing valve kit, tap and automatic air vent kit, expansion vessel for boiler (VFN19, VFN24, VFN50 depending on boiler volume), copper or stainless steel pipe for connection from panel to boiler serpentine. Optional: An electric resistance kit with thermostat 3 kW or 4.5 kW can be mounted on the ECOUNIT-2C WB boiler.
Hydraulic Scheme: Solar Panels and Wall-Mounted Boiler for DHW Preparation
Diagram Description: Hydraulic schematic for preparing domestic hot water (a.c.m.) with solar panels and a wall-mounted boiler using an external boiler. This diagram shows a different configuration involving a wall-mounted thermal unit (BlueHelix HiTech RRT H), a hydraulic group (IDRO 12S Easy), an Ecotronic PRO controller, a boiler (ECOUNIT F/HP 2C), an expansion vessel (VFN), safety valves, and sensors (S1, S2).
SOLAREVO V Flat Plate Solar Collectors
SOLAREVO V is a flat plate solar collector with forced circulation, offering high efficiency. It is certified by Keymark Solar (EN 12975), recognized as one of the most efficient solar collectors on the market (η=80%). Key features include a highly selective absorber surface made of aluminum with titanium oxide treatment, a robust frame supported by two aluminum bars for neat and versatile installation, a double-walled aluminum profile (2.4 mm) ensuring durability and enhanced insulation, and prismatic tempered glass with high transparency (3.2 mm thickness). The collector utilizes a high-performance absorber with a copper harp structure welded by laser and an ultra-selective surface of 0.5 mm. Integrated support accessories facilitate easy installation and universal compatibility. The collector is adjustable for various mounting types, including pitched or flat roofs, and uses Ø 22 mm fittings for compression connection/interconnection.
Mounting Options
Inclined Roof Mounting
Mounting Frame | Code | Fixing Supports | Code |
---|---|---|---|
Complete mounting frame for 1 collector (*) | 076239X0 | Kit of 4 supports for tile mounting | 076242X0 |
Complete mounting frame for 2 collectors (*) | 076240X0 | Kit of 4 universal consoles | 076241X0 |
(*) For mounting multiple collectors in combination, use multiple kits.
Flat Roof Mounting
Mounting Frame | Code | Extension Kit | Code |
---|---|---|---|
Base frame kit for 1 collector mod. 2.1 V | 076235X0 | Extension kit for each collector (mod. 2.1 V) - additional | 076237X0 |
Base frame kit for 1 collector mod. 2.6 V | 076236X0 | Extension kit for each collector (mod. 2.6 V) - additional | 076238X0 |
Hydraulic Accessories
Accessory | Code | Hydraulic Accessories | Code |
---|---|---|---|
Thermostatic mixer connections 1/2" | 013002X0 | Hydraulic connections (interconnection set) (EXTENSION) | 072292X0 |
Base hydraulic connections - set - first/last collector | 072291X0 | Automatic air vent | 072293X0 |
Diagram Description: Diagrams illustrating mounting options for SOLAREVO V collectors on inclined and flat roofs, showing frame and support kits. Also includes hydraulic connection diagrams.
Technical Specifications and Pressure Drop
Model | Unit | V 2.1 | V 2.6 |
---|---|---|---|
Dimensions (LxHxD) | mm | 1230 x 1696 x 86 | 1230 x 2111 x 86 |
Gross area | sqm | 2.09 | 2.60 |
Effective area | sqm | 1.96 | 2.44 |
Weight (without fluid) | kg | 34.5 | 41.2 |
Closed circuit volume | liters | 1.6 | 1.8 |
Stagnation temperature | °C | 175.2 | 175.2 |
Absorber factor | % | 95 | 95 |
Emissivity factor | % | 4 | 4 |
Collector thermal insulation | 40 mm high-density mineral wool | ||
Heat transfer circuit fittings | mm | 22 | 22 |
Max. primary circuit operating pressure | bar | 10 | 10 |
Collector fittings | nr. | 4 | 4 |
Number of units per pallet | nr. | 12 | 12 |
CODE | 0XGF1VWA | 0XGF2VWA |
Graph Description: Graph showing the pressure drop (delta p) in kPa versus volumetric flow rate (vdot) in l/h for SOLAREVO V collectors (models V 2.1 and V 2.6). The graph indicates that pressure loss increases with higher flow rates.
Solar System Accessories
Ecounit 2C WB / Ecounit 2C F Accumulation Boilers
Details on two-serpentine accumulation boilers, including technical specifications and diagrams with legends for connections.
Model | Insulation (Polyurethane) | Diameter | Height | Serpentine S1 Area | Serpentine S2 Area | Serpentine S1 Pressure Drop | Serpentine S2 Pressure Drop | Max. boiler/serpentine working temp. | Electric Resistance | Weight |
---|---|---|---|---|---|---|---|---|---|---|
mm | mm | mm | sqm | sqm | mbar | mbar | °C | kW | kg | |
ECOUNIT-2C WB | 150 rigid | 455 | 1070 | 0.74 | 0.4 | 65 | 48 | 95/110 | optional | 65 |
500 moale 100 | 750 | 1710 | 1.8 | 1.2 | 210 | 90 | 95/110 | optional | 185 | |
ECOUNIT-2C F | 200 rigid 50 | 540 | 1453 | 0.5 | 0.83 | 155 | 254 | 95/110 | 1.5 | 73 |
620 | 1535 | 0.72 | 1.00 | 220 | 308 | 95/110 | 1.5 | 103 |
Diagram Description: Diagrams of Ecounit 2C WB and Ecounit 2C F boilers with legends indicating various connection points, sensors, and components like magnesium anodes and electric resistance.
Ecotronic Pro Electronic Controllers
Ecotronic Pro is specially designed for controlling pump speeds in high-efficiency solar and heating systems. It features two PWM outputs and an additional input for a Grundfos Direct Sensor™ VFD, enabling precise heat quantity measurement. Technical data includes 4 PT1000 temperature sensor inputs, 1 Grundfos Direct Sensor™ VFD input, 1 semiconductor relay output, 1 PWM output (512 Hz frequency, 10.5 V voltage), switching capacity up to 1(1) A at 100-240V, and total switching capacity of 1A at 240V. It operates on 100-240V, 50-60 Hz, with standby power consumption less than 1W. Functions include operation control, operating hour tachometer, speed regulation, drain-back option, and calorimeter. The housing is made of plastic (PC-ABS and PMMA) and can be wall-mounted or installed in a control panel. The display shows system status with 16-segment and 7-segment displays, plus 8 system status symbols. Control is via three front buttons. Protection type is IP 20 / EN 60529, protection class is I. Ambient temperature range is 0-40°C (32-104°F). Dimensions are 172 x 110 x 46 mm.
IDRO 12S Easy / IDRO 30 N Forced Circulation Groups
Characteristics: 3-speed circulation pump, installation filling/draining valve, thermometer, wall mounting kit, expanded polystyrene insulation, expansion vessel fixing ears, safety group with safety valve and manometer, and flow adjustment valve with visual indicator.
VFN Expansion Vessels
VFN are vertical expansion vessels designed for a maximum pressure of 10 bar. They are suitable for heating, cooling, potable water, and solar applications. Features include a fully welded body, an interchangeable high-quality rubber membrane compliant with DIN 4807-3, CE compliance for pressure vessels (97/23/CE, DIN EN 13881), maximum working temperature of 99°C, minimum working temperature of -10°C, continuous working temperature of 70°C, and a preset pressure of 2 bar.
MODEL | Code | Capacity (liters) | Connections (C) | Weight (kg) | Diameter (mm) (D) | Height (mm) (H) | Preset Pressure (bar) |
---|---|---|---|---|---|---|---|
VFN 24 | VFN0024 | 24 | 1" | 3.26 | 250 | 430 | 2 |
VFN 35 | VFN0035 | 35 | 1" | 4.91 | 370 | 400 | 2 |
VFN 50 | VFN0050 | 50 | 1" | 7.65 | 370 | 695 | 2 |
VFN 80 | VFN0080 | 80 | 1" | 13.01 | 450 | 800 | 2 |
Booster - Automatic Pump
The Booster WG automatic pump is used to increase water pressure in non-pressurized solar panels. The pump rotor only works with domestic water. The pump operation can be adjusted using the switch: "O" - OFF, "I" - MANUAL Mode, "II" - AUTO Mode. It is primarily used to increase cold or hot water pressure for domestic use. Water temperature should not exceed 80°C during operation.
MODEL | Max. Flow (L/min) | Max. Head (m) | Connection (") |
---|---|---|---|
15WG-120(A/R) | 23 | 15 | G3/4 |
Notes
Electric Heater
For pressurized/non-pressurized solar panels (EcoHeat/EcoSole models). Due to climatic changes, for example, when sunlight is weak, you can use the electric resistance to heat the water in the collector. If installing the electric resistance without connecting it to a controller, ensure it is equipped with a residual current device (overvoltage protection) for safe use. Remember to turn it off before showering. Washing or taking a bath with electrical appliances nearby is strictly prohibited.
Antifreeze -30°C
Antifreeze -30°C is intended for pressurized solar installations. Applications include improving heat transfer in radiators, air conditioning units, and heating, reducing friction by 45%, and providing flocculant, anti-limescale, anti-algae, and anti-freeze effects. To use, introduce it into the installation as is. For applications with a special freezing point, the product can be supplied upon request.