Uline Pure Flow 1000® Eyewash Station

Models: H-1297, S-11507

Contact: 1-800-295-5510 | uline.com

General Information

The H-1297 shipping carton should contain:

Before installing S-11507 Pure Flow 1000® Saline Cartridges, inspect the product for damage.

NOTE: S-11507 Pure Flow 1000® Saline Cartridges are sold separately.

Cartridge Installation

NOTE: This eyewash station requires two saline cartridges to be installed at the same time.

  1. Close the drain spigot by turning the handle to the rear. (See Figure 1)
  2. Remove the cover by lifting it up. (See Figure 2A) Open the activating door. (See Figure 2B)
  3. Raise the reservoir to the "Up" position, latch onto the housing by pressing back on the latching tabs. (See Figure 3)
  4. Place two S-11507 Pure Flow 1000® Saline Cartridges on the shelf. Nozzle assembly must be in front. (See Figure 4)
  5. Pull green latch tabs forward to drop down the reservoir, ensuring that plates are seated on bags and are not resting on the cartridge boxes. (See Figure 5)
  6. Replace the cover. (See Figure 6)
  7. Remove rubber bands from the activating strap and nozzle. Extend activating straps to the side. Do not pull on the straps. (See Figure 7)
  8. Snap the right-hand nozzle into place on the white nozzle plate. An audible 'click' will be heard to confirm that the nozzle is engaged. (See Figure 8)
  9. Snap the left-hand nozzle into place on the white nozzle plate. An audible 'click' will be heard to confirm that the nozzle is engaged. (See Figure 9)
  10. Position the two black straps over the top of the activation door with the expiration date and batch number visible. Do not twist or cross straps. Close the activation door. (See Figure 10)
  11. Position the activating straps over the door and down the raised area on either side of the door handle so the straps cover the labels on the activation door. (See Figure 11)
  12. Push the plastic fastener into the hole in the door until the flange is seated against the door. (See Figure 11)
  13. Push the center pin of the fastener until it snaps into place flush with the fastener head. (See Figure 11)
  14. Position the tamper seal on the middle right-hand side of the door. Half the seal must be on the door and the other half on the unit surface. (See Figure 12)
  15. Attach the lock or inspection tag through the tab on the cover. (See Figure 12)

Figure 1: Drain Spigot Operation

Diagram shows a drain spigot with a handle. The handle can be turned to the rear to close the spigot. Two positions are shown: Open and Closed.

Figure 2A & 2B: Cover and Activating Door

Figure 2A shows a cover being lifted up. Figure 2B shows the activating door being opened, with arrows indicating the direction of movement.

Figure 3: Reservoir Latching

Diagram shows the reservoir being raised to the 'Up' position and latched onto the housing by pressing back on the latching tabs.

Figure 4: Cartridge Placement

Diagram shows two saline cartridges being placed on a shelf with the nozzle assembly facing forward.

Figure 5: Reservoir Drop-Down

Diagram shows green latch tabs being pulled forward to drop the reservoir. It emphasizes ensuring plates are seated on bags and not resting on cartridge boxes.

Figure 6: Cover Replacement

Diagram shows the cover being placed back onto the unit.

Figure 7: Strap and Nozzle Preparation

Diagram shows rubber bands being removed from the activating strap and nozzle, and the activating straps being extended to the side.

Figure 8: Right Nozzle Engagement

Diagram shows the right-hand nozzle being snapped into place on the white nozzle plate. An audible click confirms engagement.

Figure 9: Left Nozzle Engagement

Diagram shows the left-hand nozzle being snapped into place on the white nozzle plate. An audible click confirms engagement.

Figure 10: Strap Positioning

Diagram shows the two black straps positioned over the activation door, ensuring the expiration date and batch number are visible. The straps should not be twisted or crossed.

Figure 11: Fastener Installation

Diagram shows the activating straps positioned over the door and down the sides of the handle to cover labels. A plastic fastener is pushed into the door, and its center pin is pushed to secure it flush with the head.

Figure 12: Seal and Tag Attachment

Diagram shows a tamper seal being positioned on the right side of the door, covering both the door and the unit surface. An inspection tag or lock is attached through a tab on the cover.

Models: Pure Flow 1000 Eyewash Station

File Info : application/pdf, 12 Pages, 2.00MB

PDF preview unavailable. Download the PDF instead.

IH-1297-SPFR Adobe InDesign 14.0 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview Uline H-5457, H-5795 Wall Mount Eyewash Station Installation and Maintenance Guide
Comprehensive guide for the installation, maintenance, and ANSI/ISEA Z358.1 compliance of the Uline H-5457 and H-5795 Wall Mount Eyewash Station. Includes instructions in English, Spanish, and French.
Preview ULINE H-6224 Mobile Eyewash Station - Parts and Specifications
Detailed parts list and diagram for the ULINE H-6224 Mobile Eyewash Station, including part numbers and descriptions for replacement components. Features safety equipment specifications.
Preview ULINE H-6618 Stainless Steel Shower Eyewash Station - Product Information
Detailed information and parts list for the ULINE H-6618 Stainless Steel Shower Eyewash Station, a safety and emergency equipment product.
Preview ULINE H-6697 Shower Eyewash Station Assembly Instructions
Comprehensive assembly guide for the ULINE H-6697 Shower Eyewash Station. Provides step-by-step instructions, part identification, and critical assembly notes for ensuring proper installation and function, compliant with ANSI Z358.1 standards.
Preview Uline H-5101 Shower Eyewash Station Parts and Assembly
Detailed parts list and assembly information for the Uline H-5101 Shower Eyewash Station, including part numbers and manufacturer part numbers.
Preview ULINE H-1036 Electronic Kraft Tape Dispenser - Parts List and Diagram
Comprehensive parts list and exploded view diagram for the ULINE H-1036 Electronic Kraft Tape Dispenser. Find part numbers, descriptions, and manufacturer details for efficient maintenance and replacement.
Preview Uline H-7630, H-7631 Packing Station Assembly and Accessories Guide
Comprehensive guide for assembling the Uline H-7630 and H-7631 Packing Stations, including detailed instructions, parts lists, hardware information, and optional accessory installations.
Preview ULINE Counting Scales Troubleshooting Guide | H-1114, H-1115, H-1116, H-1117, H-1121, H-1122, H-1123
Troubleshoot common issues with ULINE Counting Scales (models H-1114 to H-1123). Find solutions for accuracy, power, placement, and performance to ensure reliable operation.