Bertazzoni 36-Inch Dual Fuel Range Installation Details
Side View
Diagram showing the side profile of the range with key dimensions:
- Height: 27 1/2" (698 mm)
- Depth: 25 1/4" (640 mm)
- Overall Height (including legs): 47" (1193 mm)
- Leg height adjustment indicated as A.
Front View
Diagram showing the front of the range with key dimensions and features:
- Width: 35 7/8" (911 mm)
- Height: 32" (814 mm) - labeled as 32" 814 + A, indicating leg adjustment
- Features include control knobs and an oven door.
- Leg detail shows a height of 5 1/8" (129 mm) and an adjustment range of 4"-5 1/8" (100-131 mm).
Rear View
Diagram showing the rear profile of the range with key dimensions:
- Depth: 26 7/8" (684 mm)
- Height: 32" (814 mm)
- Width: 35 7/8" (911 mm)
- Features labeled 'a' and 'b' indicate connection points.
Worktop Details
Diagram illustrating the cooktop layout and dimensions:
- Overall Width: 35 7/8" (911 mm)
- Overall Depth: 20 1/8" (512 mm)
- Burner spacing and dimensions are shown, with individual burner diameters indicated by the 11" (279 mm) measurements.
- A 2" (50 mm) clearance is noted.
Installation Requirements
Specific instructions for electrical and gas connections:
Electrical Connection (E)
A properly-grounded horizontally mounted electrical receptacle should be installed:
- No higher than 3" (7.6 cm) above the floor.
- No less than 2" (5 cm) from the left side (facing product).
- No more than 8" (20.3 cm) from the left side (facing product).
Check all local code requirements.
Gas Connection (G)
Install an agency-approved, properly sized manual shut-off valve:
- Maximum height of 3" from the floor.
- Minimum height of 2" from the right side (facing product).
- Maximum height of 8" from the right side (facing product).
Use an approved shut-off valve & regulator gas connection, with properly sized flex or rigid pipe. Check all local code requirements.
Installation Diagram
A diagram illustrates recommended clearances and placement for electrical (E) and gas (G) connections relative to the range, with dimensions such as 13" (330 mm), 18" (457 mm), and 36" (914/915 mm) for cabinet and overall height.
For installation with a hood, refer to the manufacturer's installation requirements.
Notes
- a. Electrical Connection
- b. Gas Connection