BRINK
Air for life
Technical Data Sheet
Flair 450/600
English
1 Delivery
1.1 Delivery size
Before installation of the heat recovery appliance is started, check that it has been supplied in complete and undamaged condition.
The delivery size of the heat recovery appliance type Flair 450/600 consists of the following components:
- 1. Heat recovery appliance
- 2. Wall mounting bracket consisting of:
- 1x mounting bracket
- 2x protective caps
- 2x rubber strip
- 3x rubber rings
- 1x washer
- 3. Siphon
- 4. Documentation set consisting of:
- 1x short installation instructions
- 1x occupant's instructions
2 Version
2.1 Technical information Flair 450
Parameter | Value |
---|---|
Supply voltage [V/Hz] | 230V/50Hz |
Dimensions (w x h x d) [mm] | 850 x 800 x 660 |
Duct diameter [mm] | Ø200 |
Ext. diameter condensate discharge [mm] | Ø32 |
Weight [kg] | 49 |
Filter class | ISO Coarse 60% (ISO ePM1.0 50% for the air supply optional) |
Fan setting (factory setting) | 0, 1, 2, 3, max |
Factory setting [m³/h] | 75, 100, 200, 300, 450 |
Permissible resistance of duct system [Pa] | 3, 6, 5, 10, 20, 40, 44, 89, 100, 200 |
Rated power (excl. preheater) [W] | 10.4, 10.8, 12.4, 13.2, 17.6, 23.8, 51.9, 69.3, 149.5, 198.8 |
Rated current (excl. preheater) [A] | 0.17, 0.17, 0.19, 0.19, 0.20, 0.27, 0.53, 0.69, 1.32, 1.68 |
Max. rated current (incl. preheater switched on) [A] | 5.2 |
Rated power preheater [W] | 1000 |
Cos φ | 0.271, 0.274, 0.291, 0.295, 0.378, 0.383, 0.425, 0.437, 0.492, 0.514 |
Sound power
Ventilation capacity [m³/h] | 100 | 200 | 200 | 300 | 300 | 450 | 450 |
---|---|---|---|---|---|---|---|
Static pressure [Pa] | 25 | 25 | 50 | 50 | 100 | 100 | 150 |
Casing radiation [dB(A)] | < 38.1 | 36.5 | 42.0 | 45.5 | 46.0 | 51.7 | 54.0 |
Sound power level Lw(A) | |||||||
Duct "Extract air" [db(A)] | < 36.3 | 38.5 | 40.0 | 45.0 | 42.5 | 49.0 | 49.5 |
Duct "Supply Air" [db(A)] | < 38.5 | 43.5 | 47.5 | 53.0 | 53.5 | 58.6 | 59.0 |
*) Duct noise including end correction. In practice the value may differ by 1dB(A) through measurement tolerances.
2.2 Technical information Flair 600
Parameter | Value |
---|---|
Supply voltage [V/Hz] | 230V/50Hz |
Dimensions (w x h x d) [mm] | 850 x 800 x 660 |
Duct diameter [mm] | Ø200 |
Ext. diameter condensate discharge [mm] | Ø32 |
Weight [kg] | 49 |
Filter class | ISO Coarse 60% (ISO ePM1.0 50% for the air supply optional) |
Fan setting (factory setting) | 0, 1, 2, 3, max |
Factory setting [m³/h] | 100, 150, 300, 500, 600 |
Permissible resistance of duct system [Pa] | 3, 6, 6, 13, 25, 50, 69, 139, 100, 188 |
Rated power (excl. preheater) [W] | 12.1, 12.5, 17.2, 18.3, 44.5, 54.2, 166.6, 203.1, 260.6, 288.0 |
Rated current (excl. preheater) [A] | 0.18, 0.19, 0.23, 0.24, 0.46, 0.55, 1.45, 1.71, 2.11, 2.3 |
Max. rated current (incl. preheater switched on) [A] | 5.7 |
Rated power preheater [W] | 1000 |
Cos φ | 0.288, 0.291, 0.322, 0.327, 0.421, 0.427, 0.500, 0.516, 0.536, 0.544 |
Sound power
Ventilation capacity [m³/h] | 150 | 300 | 300 | 500 | 500 | 600 | 600 |
---|---|---|---|---|---|---|---|
Static pressure [Pa] | 25 | 50 | 100 | 100 | 150 | 100 | 150 |
Casing radiation [dB(A)] | 37.5 | 45.5 | 46.0 | 56.0 | 54.5 | 56.5 | 56.5 |
Sound power level Lw(A) | |||||||
Duct "Extract Air" [db(A)] | 35.0 | 45.0 | 42.5 | 51.0 | 52.0 | 53.5 | 56.5 |
Duct 'To dwelling' [db(A)] | 43.5 | 53.0 | 53.5 | 60.5 | 61.5 | 62.0 | 66.6 |
*) Duct noise including end correction. In practice the value may differ by 1dB(A) through measurement tolerances.
2.3 Connections and dimensions
The Flair appliance is available in a left-hand and right-hand version. With a left-hand version the "warm" connections (from dwelling 3 and to dwelling 1) are on the left-hand side of the appliance; the condensate discharge is then mounted at the right-hand opening below the appliance. With a right-hand version the "warm" connections (1 & 3) are on the right-hand side of the appliance.
Left-hand version
No. | Description | Symbol |
---|---|---|
1 | Supply air | ↑ |
2 | Exhaust air | ↓ |
3 | Extract air | ↑ |
4 | Outdoor air | ↓ |
5 | Electrical connections | |
6a | Siphon connection | |
6b | Sealing cap unused condensate discharge connection; do not remove! | |
7 | Extract air filter | |
8 | Supply air filter | |
9 | Mounting bracket |
All dimensions in millimeters. Diameter of all collars is 200 mm.
Right-hand version
No. | Description | Symbol |
---|---|---|
1 | To dwelling | ↑ |
2 | Exhaust air | ↓ |
3 | Extract air | ↑ |
4 | Outdoor air | ↓ |
5 | Electrical connections | |
6a | Siphon connection | |
6b | Sealing cap unused condensate discharge connection; do not remove! | |
7 | Extract air filter | |
8 | Supply air filter | |
9 | Mounting bracket |
All dimensions in millimeters. Diameter of all collars is 200 mm.
2.4 Exploded view of appliance
No. | Component Name |
---|---|
1 | Touchscreen |
2 | USB connector (X13) |
3 | Service connector |
4 | LED indicator |
5 | Maximum protection preheater |
6 | Preheater |
7 | Temperature sensor (2x) |
8 | Supply filter |
9 | Exhaust fan |
10 | Siphon |
11 | Supply fan |
12 | Heat exchanger |
13 | Motor bypass valve |
14 | Exhaust air filter |
15 | Bypass valve |
16 | Power cable 230 volt |
17 | Signal output (X19) |
18 | 24 volt connector (X18) |
19 | eBus connector (X17) |
20 | 24 volt connector (X16) |
21 | Modbus/ internal bus connector (X15) |
22 | Multiple switch connector (X14) |
3 Service
3.1 Exploded view
When ordering parts, in addition to the article code number (see exploded view), please state the heat recovery appliance type, the serial number, the year of production, and the name of the part.
N.B.: Appliance type, serial number, and year of production are stated on the identification plate behind the plastic front panel on the appliance.
Example Order Information
Field | Details |
---|---|
Appliance type | Flair 450/600 |
Serial number | 432000221201 |
Year of production | 2023 |
Part | Fan |
Article code | 533037 |
Quantity | 1 |
3.2 Service articles
No. | Article description | Article code |
---|---|---|
1 | Front panel complete Flair 450 | 532828 |
1 | Front panel complete Flair 600 | 532826 |
2 | Filters (2 items) ISO Coarse 60% | 532821 |
3 | Heat exchanger | 532885 |
4 | Fan (1 item) | 533037 |
5 | Cable set | 532891 |
6 | Temperature sensor NTC 10K (1 item) | 531775 |
7 | Bypass valve with motor complete | 532760 |
8 | Display pcb UBP-2 | 532752 |
9 | Mains plug and cable 230 V * | 532929 |
10 | Appliances manufactured before 01-01-2023: Basic pcb UWA2-B + display | 532750 |
10 | Appliances manufactured after 01-01-2023: Basic pcb UWA2-B | 532966 |
11 | Collars 200 mm | 532899 |
12 | Maximum security | 532769 |
13 | Internal preheater | 532886 |
14 | Condensation discharge | 532762 |
* The power cable is fitted with a circuit board connector. When replacing it, always order a replacement mains cable from Brink. To prevent dangerous situations, a damaged mains connection can only be replaced by a qualified expert.
4 Conformity declaration
Manufacturer: Brink Climate Systems B.V.
Address: P.O. Box 11, NL-7950 AA, Staphorst, The Netherlands
Product: Heat recovery appliance type: Flair 450, Flair 600
The product described above complies with the following directives:
- 2014/35/EU (OJEU L 96/357; 29-03-2014)
- 2014/30/EU (OJEU L 96/79; 29-03-2014)
- 2009/125/EU (OJEU L 285/10; 31-10-2009)
- 2017/1369/EU (OJEU L 198/1; 28-07-2017)
- RoHS 2011/65/EU (OJEU L 174/88; 01-07-2011)
The product described above has been tested according to the following standards:
- EN IEC 55014-1: 2021
- EN IEC 55014-2: 2021
- EN IEC 61000-3-2: 2019 + A1:2021
- EN 61000-3-3: 2013 + A1:2019 + A2:2021
- EN 60335-1: 2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021
- EN 60335-2-40: 2003 + A11:2004 + A12:2005 +AC:2006 + A1:2006 + A2:2009 + AC:2010 + A13:2012
- EN 62233: 2008 + AC:2008
Staphorst, 07-06-2023
A. Hans
Managing Director
5 ERP values Flair 450
Technical information sheet Flair 450 in accordance with Ecodesign (ErP), no. 1254/2014 (Annex IV)
Manufacturer: Brink Climate Systems B.V.
Model: Flair450
Climate zone | Type of control | SEC Value in kWh/m²/a | SEC Class | Annual electricity consumption (AEC) in kWh | Annual heating saved (AHS) in kWh |
---|---|---|---|---|---|
Average | manual | -40.06 | A | 283 | 4646 |
clock control | -40.76 | A | 260 | 4658 | |
1x sensor (RV/CO2/VOC) | -42.09 | A+ | 217 | 4684 | |
2 or more sensors (RV/CO2/VOC) | -44.38 | A+ | 146 | 4735 | |
Cold | manual | -79.11 | A+ | 820 | 9088 |
clock control | -79.94 | A+ | 797 | 9113 | |
1x sensor (RV/CO2/VOC) | -81.51 | A+ | 754 | 9163 | |
2 or more sensors (RV/CO2/VOC) | -84.29 | A+ | 683 | 9263 | |
Hot | manual | -15.06 | E | 283 | 2101 |
clock control | -15.69 | E | 215 | 2106 | |
1x sensor (RV/CO2/VOC) | -16.88 | E | 172 | 2118 | |
2 or more sensors (RV/CO2/VOC) | -18.90 | E | 101 | 2141 |
Type of ventilation unit: Balanced residential ventilation appliance with heat recovery
Fan: EC - fan with infinitely variable control
Type of heat exchanger: Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency: 92%
Maximum flow rate: 450 m³/h
Maximum rated power: 192 W
Sound power level Lwa: 47 dB(A)
Reference flow rate: 315 m³/h
Reference pressure: 50 Pa
Specific Power Input (SEL): 0.20 Wh/m³
Control factor:
- 1.0 in combination with multiple switch
- 0.95 in combination with clock control
- 0.85 in combination with 1 sensor
- 0.65 in combination with 2 or more sensors
Leakage*: Internal: 0.90%, External: 0.90%
Position dirty filter indication: On the display of the appliance / on the multiple switch (LED) / on the Brink Air Control.
Attention! For optimal energy efficiency and a proper operation, a regular filter inspection, cleaning or replacement is necessary.
Internet address for Assembly instructions: https://www.brinkclimatesystems.nl/support/downloads
Bypass: Yes, 100% Bypass
* Measurements executed by TZWL according to the DiBt-standards
SEC Class Classification (Average climate zone)
SEC class ("Average climate zone") | SEC in kWh/m²/a |
---|---|
A+ (Most efficient) | SEC < -42 |
A | -42 < SEC < -34 |
B | -34 < SEC < -26 |
C | -26 < SEC < -23 |
D | -23 < SEC < -20 |
E (Least efficient) | -20 < SEC < -10 |
6 ERP values Flair 600
Technical information sheet Flair 600 in accordance with Ecodesign (ErP), no. 1254/2014 (Annex IV)
Manufacturer: Brink Climate Systems B.V.
Model: Flair 600
Climate zone | Type of control | SEC Value in kWh/m²/a | SEC Class | Annual electricity consumption (AEC) in kWh | Annual heating saved (AHS) in kWh |
---|---|---|---|---|---|
Average | manual | -38.02 | A | 358 | 4630 |
clock control | -38.92 | A | 328 | 4643 | |
1x sensor (RV/CO2/VOC) | -40.60 | A+ | 271 | 4670 | |
2 or more sensors (RV/CO2/VOC) | -43.49 | A+ | 177 | 4724 | |
Cold | manual | -76.92 | A+ | 895 | 9057 |
clock control | -77.95 | A+ | 865 | 9083 | |
1x sensor (RV/CO2/VOC) | -79.89 | A+ | 808 | 9136 | |
2 or more sensors (RV/CO2/VOC) | -83.29 | A+ | 714 | 9242 | |
Hot | manual | -13.11 | E | 313 | 2093 |
clock control | -13.93 | E | 283 | 2100 | |
1x sensor (RV/CO2/VOC) | -15.46 | E | 226 | 2112 | |
2 or more sensors (RV/CO2/VOC) | -18.06 | E | 132 | 2136 |
Type of ventilation unit: Balanced residential ventilation appliance with heat recovery
Fan: EC - fan with infinitely variable control
Type of heat exchanger: Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency: 92%
Maximum flow rate: 600 m³/h
Maximum rated power: 288 W
Sound power level Lwa: 53 dB(A)
Reference flow rate: 420 m³/h
Reference pressure: 50 Pa
Specific Power Input (SEL): 0.25 Wh/m³
Control factor:
- 1.0 in combination with multiple switch
- 0.95 in combination with clock control
- 0.85 in combination with 1 sensor
- 0.65 in combination with 2 or more sensors
Leakage*: Internal: 0.70%, External: 0.70%
Position dirty filter indication: On the display of the appliance / on the multiple switch (LED) / on the Brink Air Control.
Attention! For optimal energy efficiency and a proper operation, a regular filter inspection, cleaning or replacement is necessary.
Internet address for Assembly instructions: https://www.brinkclimatesystems.nl/support/downloads
Bypass: Yes, 100% Bypass
* Measurements executed by TZWL according to the DiBt-standards
SEC Class Classification (Average climate zone)
SEC class ("Average climate zone") | SEC in kWh/m²/a |
---|---|
A+ (Most efficient) | SEC < -42 |
A | -42 < SEC < -34 |
B | -34 < SEC < -26 |
C | -26 < SEC < -23 |
D | -23 < SEC < -20 |
E (Least efficient) | -20 < SEC < -10 |
7 Recycling
Recycling
Sustainable materials are used in the manufacture of this appliance. The packaging should be disposed of in a responsible manner and in accordance with governmental regulations.