Installation Guide for APsystems models including: 4271901072 Energy Communication Unit ECU-R, 4271901072, Energy Communication Unit ECU-R, Communication Unit ECU-R, Unit ECU-R
Europe, Middle East, Africa Library – APsystems EMEA
Latin America Library – APsystems Latin America | The global leader in multi-platform MLPE technology
File Info : application/pdf, 26 Pages, 2.97MB
DocumentDocumentInstallation / User Manual APsystems Energy Communication Unit ECU-R Please scan this QR code to download our APPs or click the link below: http://q-r.to/1OrC © All Rights Reserved Table of Contents 1. Introduction .................................................................................................................................. 2 2. Interface Explanation .....................................................................................................................3 2.1 Interface Layout .........................................................................................................3 2.2 Reset .......................................................................................................................... 4 2.3 Power Connection Port ............................................................................................. 4 2.4 RJ45 Ethernet Network Port ......................................................................................4 2.5 RJ45 Signal (Only for Australia) ..................................................................................4 2.6 Antenna ..................................................................................................................... 4 2.7 AP ...............................................................................................................................5 2.8 LED1 ........................................................................................................................... 5 2.9 LED2 ........................................................................................................................... 5 3. Hardware Installation .................................................................................................................... 6 3.1 Preparation ................................................................................................................ 6 3.2 Selecting an Installation Location for the ECU-R ....................................................... 6 3.3 Installation ................................................................................................................. 6 3.4 Cable Connection ...................................................................................................... 7 3.5 Internet Connection .................................................................................................. 9 4. ECU-R User Interface ....................................................................................................................10 4.1 Commissioning the ECU-R ....................................................................................... 10 4.2 Enter microinverters UID (serial numbers) into the ECU-R ..................................... 11 4.3 Historical ID ............................................................................................................. 12 4.4 Delete UID ............................................................................................................... 12 4.5 Grid Profile ...............................................................................................................13 4.6 Time management .................................................................................................. 14 4.7 Modbus Settings ......................................................................................................14 4.8 ECU Network Settings ..............................................................................................15 4.9 Checking the commissioning of the ECU-R ............................................................. 18 4.10 Module .................................................................................................................. 19 4.11 Data ....................................................................................................................... 20 4.12 Inverter Connection Progress ................................................................................20 4.13 Automatic System Check ....................................................................................... 21 4.14 ECU AP Settings ..................................................................................................... 21 4.15 Do-It-Yourself(DIY) Registration .............................................................................22 4.16 Settings .................................................................................................................. 22 5. Technical Data ..............................................................................................................................23 5.1 Disposal ................................................................................................................... 23 6. Contact Information .....................................................................................................................25 APsystems ECU-R Installation/User Manual 1 1. Introduction The APsystems Energy Communication Unit (ECU-R) is the information gateway for our microinverters. The ECU-R collects module performance data from each individual microinverter and transfers the information to an Internet database in real time. Through the APsystems Energy Monitoring and Analysis (EMA) software, the ECU-R gives you precise analysis of each microinverter and PV module in your solar installation powered by APsystems. The user-friendly interface gives you access to your solar array performance in seconds from our web based portal or from our APP. Features Collects individual PV module and microinverter statistics Communicates in real time Requires no additional wiring The APsystems ECU-R is used in utility-interactive grid-tied applications, typically consisting of five key elements: APsystems microinverter(s) APsystems Energy Communication Unit (ECU-R) EMA Manager APP: for installer to set-up the ECU-R EMA APP: to enable end-users to have access to the data and performance of their system anytime, anywhere APsystems Energy Monitoring and Analysis (EMA): web-based monitoring and analysis system, for both end-users and installers microinverter PV Module Junction Box Meter Energy Communication Unit Neutral Ground APP Internet EMA Figure 1 APsystems ECU-R Installation/User Manual 2 2. Interface Explanation 2.1 Interface Layout The ECU-R interface includes, (figure 2) from left to right Reset button Wifi antenna connector (WLAN communication between ECU and router) power connection port RJ45 Signal port (for Australia only) RJ45 ethernet network port (LAN communication between ECU and router) Zigbee antenna connector (communication between ECU and microinverters) Reset Antenna (WIFI) RJ45 ethernet network port Antenna (ZigBee) Figure 2 On the side ECU: from top to bottom are: USB port: for reserved. AP button: in case there is need to activate the ECU-R hotspot (see later in the document) Figure 3 APsystems ECU-R Installation/User Manual 3 2. Interface Explanation 2.2 Reset Press the Reset button for a minimum of three seconds: the ECU-R will automatically return to the default settings. 2.3 Power Connection Port The power connection port connects power through the power adapter. 2.4 RJ45 Ethernet Network Port The ECU-R allows the user to communicate with the EMA server via Ethernet cable. 2.5 RJ45 Signal (Only for Australia) The RJ45 Signal is designed for DRM0, it should be connected by RJ45 connector in the package otherwise the inverter will not work. Please do not plug out the RJ45. 2.6 Antenna The antennas supplied with the ECU-R must be connected to the ECU-R. One antenna is used for the communication between ECU-R and microinverters (Zigbee signal), the other antenna is used for the Wi-Fi connection between ECU-R and router. APsystems ECU-R Installation/User Manual 4 2. Interface Explanation 2.7 AP The AP button enables to turn on the ECU wifi hotspot. When setting up the ECU, installer needs to first connect to the ECU hotspot via his smart phone or tablet. Press the AP button for a few seconds: the ECU hotspot will be live for one hour. If more time is needed to set-up the ECU, press the AP button to reactivate the hotspot. 2.8 LED1 LED1 will be ON (green light) when the ECU is powered ON Figure 4 2.9 LED2 LED2 will be ON (green light) when the ECU is exchanging data with the EMA server. When you haven't entered microinverters UID into the ECU-R, or The ECU cannot connect to the EMA server, LED2 is OFF. APsystems ECU-R Installation/User Manual 5 3. Hardware Installation 3.1 Preparation Make sure you have the following components ready before beginning the installation of the ECU-R: A standard AC electrical outlet (located as close as possible of the PV array to ensure good communication between ECU and microinverters). A broadband Internet connection available for your use. A broadband router with either a CAT5 Ethernet, or a wireless router. A smartphone or tablet with EMA Manager APP ready to use (see page 11). 3.2 Selecting an Installation Location for the ECU-R Choose a location that is as close as possible of the PV array. The ECU-R is NOT rated for outdoor use. If installing outdoor, ensure that the ECU-R is put in a waterproof box, and that the antenna (wifi and Zigee) are placed outside of the box to ensure optimum communication. In case you need to use extension antennas to be closer to the PV array, please make sure the extension antennas are Wifi 2.4GHz with SMA connectors male/female. These extension antennas are not supplied by APsystems, but can be purchased at any electrical/PV shop. 3.3 Installation 1) Using a Wall Mount When mounting the ECU-R to a wall, make sure to select a cool, dry indoor location. Depending on the wall surface you are mounting the ECU-R to, use either two drywall screws or wall anchors, installed 100 mm apart (The drywall screws and wall anchors are not included in the ECU-R kit). Align and slide the ECU-R onto the mounting screws. Figure 5 APsystems ECU-R Installation/User Manual 6 3. Hardware Installation 2) if the HECU-R is not mounted on a wall mount, you can put it anywhere on a flat surface or furniture, close to a power outlet. 3.4 Cable Connection 1) ECU-R outside of a cabinet (wall mounted or not) Connect the adapter to the power connection port at the back of the ECU-R. Figure 6 The antennas used for ZigBee port and WI-FI port are exactly the same type and are interchangeable. APsystems ECU-R Installation/User Manual 7 3. Hardware Instrallation 2Installation inside a power cabinet Install the socket on the guide rail (The socket is not be supplied by APsystems). Connect the adapter to the power connection port at the back of the ECU-R. Figure 7 ECU antennas must be left outside of the cabinet, even if the cabinet is made of plastic. Please make sure the extension antennas are Wifi 2.4GHz with SMA connectors male/female. These extension antennas are not supplied by APsystems, but can be purchased at any electrical/PV shop. APsystems ECU-R Installation/User Manual 8 3. Hardware Installation 3.5 Internet Connection There are two different approaches to connect the ECU-R to the Internet: Option 1: Direct LAN cable connection. 1) Make sure the LAN cable is connected to the network port on the back of the ECU-R. 2) Connect the LAN cable to a spare port on the broadband router. See more info later in the document. Option 2: Wireless Connection. Use ECU-R internal WLAN (see later in the document, page 15 ). Figure 8 ECU-R can communicate with the microinverters up to 76 meters (250 ft) with direct sight. ECU-R can utilize WiFi (WLAN) up to 9 meters (30 ft) with direct sight. 4G router is also supported. ECU can be connected to 4G router by wifi or LAN. LAN 4G SIM Figure 9 APsystems ECU-R Installation/User Manual 9 4. ECU-R User Interface Please scan QR code below to have access to our products and APP catalogue, or click this link to download our APPs: http://q-r.to/1OrC. EMA Manager APP: for installers Professional installers: all features available DIY (Do It Yourself) installers: only ECU_APP features available EMA APP: for end-users only 4.1 Commissioning the ECU-R Make sure you have downloaded the EMA Manager APP on your smartphone or tablet. Make sure the ECU-R hotspot is activated (if not, press the AP button for a few second). Open Settings > Wi-Fi in your smartphone or tablet. Select ECU-R hotspot: name is ECU_R_216xxxx (mimicking ECU-R serial number). Connect your smartphone or tablet to the ECU-R hotspot. Default password is "88888888" (8 times 8). Once the connection is established with the ECU-R hotspot, open the EMA Manager APP. Select "ECU APP" to enter into the commissioning tool (you can access to ECU APP without any login or password). APsystems ECU-R Installation/User Manual 10 4. ECU-R User Interface 4.2 Enter microinverters UID (serial numbers) into the ECU-R Click "Workspace", select "ID Management", input the microinverters UID (serial number: 12 digits starting with a 4, a 5, a 7 or a 8) manually or scan the UID with your smartphone or tablet scanner. Once the microinverters UID have been entered, please press "Sync". Please do not enter the ECU UID into the ID management menu (serial number of 12 digits starting with 216-). APsystems ECU-R Installation/User Manual 11 4. ECU-R User Interface 4.3 Historical ID If the ECU accidentally emptied the inverter list, you can use the same mobile phone to quickly restore the inverter id list. 4.4 Delete UID In case of wrong entry or typo, select the microinverter UIDs, click "Delete" then click "Sync". The selected UID(s) will be removed from the ECU-R. Note: when deleting, please press also "Sync". Otherwise the microinverter will not be removed from the ECU-R. Once the microinverters UID have been successfully entered into the ECU-R, you need to select grid profile and define the adequate time zone of your ECU. APsystems ECU-R Installation/User Manual 12 4. ECU-R User Interface 4.5 Grid Profile From the work space, select "Grid profile". First select country and then the city. If you select the wrong grid profile, the microinverters may not start or may not produce as per optimal performance. APsystems ECU-R Installation/User Manual 13 4. ECU-R User Interface 4.6 Time management From the workspace, please select menu "ECU Date Settings" manual set-up, click "Date", "Time" and "Timezone" to modify. Automated set-up: Click "Time quick setting": the APP will synchronise on the time and time zone as per smartphone or tablet settings. 4.7 Modbus Settings As shown in Figure 9 below, RS485 interface is on the bottom of the ECU. It can be connected by Serial line. Figure 10 For three-phase Microinverter: Please refer to the document Altenergy_Power_System_Inc.___three_phase_microinverter_11-12.xlsx on SunSpec website. https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc. ___three_phase_microinverter_11-12.xlsx APsystems ECU-R Installation/User Manual 14 4. ECU-R User Interface For single-phase Microinverter: Please refer to the document Altenergy_Power_System_Inc.___single_phase_MicroinverterAPpcs_11-12 on SunSpec website. https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc. ___single_phase_MicroinverterAPpcs_11-12.xlsx Click Modbus Settings in the Workspace, switch on the SunSpec Modbus function. Select the baud rate and configure Inverters ' address in the address text box. Finally, click Save to finish configuration. The host's RS485 port must be configured to the same baud rate, 8 data bits, 1 stop bit, none parity bit. 4.8 ECU Network Settings 4.8.1 WLAN From the Workspace menu, select "ECU Network settings". Swipe down the screen, the available SSIDs will be displayed . Select the network of your choice and enter its password. When connecting to the local Wifi, the smartphone or tablet may lose its connection to the ECU hotspot and connect to other wifi network or 4G. If more operations are needed to finish-up the ECU commissioning, please make sure to reconnect your smartphone or tablet to the ECU hotspot (may have to press the AP button to re-activate the hotspot). APsystems ECU-R Installation/User Manual 15 4. ECU-R User Interface When your smartphone or tablet is connected to the ECU hotspot again, you can open the ECU APP home page and check the internet connection status. The first bullet (with ECU UID) is green when the smartphone/tablet is properly connected to the ECU hotspot. The 2nd bullet shall be green if the internet connection to the router has been successfully established. APsystems ECU-R Installation/User Manual 16 4. ECU-R User Interface 4.8.2 LAN Make sure the LAN cable is connected to the network port on the back of the ECU-R. Connect the LAN cable to a spare port on the broadband router. ECU's wired network setting has 2 options: automatically obtain an IP address: the router will give an IP address to the ECU-R automatically (preferred method) . use a fixed IP address. In that case, you need to enter enter IP address, subnet mask, default gateway, Preferred DNS server and Alternate DNS server. Once the LAN connection has been established, you can check the internet connection on the home page of the ECU APP: The first bullet (with ECU UID) is green when the smartphone/tablet is properly connected to the ECU hotspot. The 2nd bullet shall be green if the internet connection to the router has been successfully established. APsystems ECU-R Installation/User Manual 17 4. ECU-R User Interface 4.9 Checking the commissioning of the ECU-R Once the ECU-R has been commissioned, installer can check status on the home page of the ECU APP: Several infos are displayed - Systems info (ECU UID, serial number) - number of microinverters communicating with the ECU / total number of microinverters entered in the ECU (using the ID Management menu). APsystems ECU-R Installation/User Manual 18 4. ECU-R User Interface Status of connectivity The traffic light (on the left) in front of the ECU UID shows connectivity status between smartphone or tablet and ECU hotspot: Smartphone or tablet is connected to the ECU hotspot. Smartphone or tablet is not connected to the ECU hotspot. Please try again by pressing the AP button. The traffic light (on the right) shows connectivity status between the ECU and the local internet: The ECU is connected to the local internet. The ECU is not connected to the internet. Other info visible from the home page power output of the day -Total power output since installation -COReduction since installation. 4.10 Module This page displays the microinverters entered in the ECU (via the Menu ID Management) and properly registered by the ECU. A dual microinverter will be shown by default with 2 PV modules, while a quad microinverters will be shown by default with 4 PV modules. if some DC channels are not connected on purpose, the ECU_APP will nonetheless continue to display the maximum number of panels which can be connected to a given microinverter. Removing un-used channel needs to be done from the EMA installer account when creating end-user account. On the module page, installer can visualize the performance of microinverters registered into the ECU. Click "Panel": the detailed information of the microinverter is displayed, including inverter UID, PV module DC power, grid voltage, frequency and temperature. APsystems ECU-R Installation/User Manual 19 4. ECU-R User Interface 4.11 Data In this Menu, you can view the detailed data at system level: -Per day -Per month 4.12 Inverter Connection Progress This menu shows the connection progress and communication quality between microinverter and ECU, 100% means the connection is over. The microinverters with "OK" are properly connected to the ECU APsystems ECU-R Installation/User Manual 20 4. ECU-R User Interface 4.13 Automatic System Check Once the ECU has been commissioned, the menu "Automatic System Check" can help you to check proper communication and production of each microinveter. This menu also gives some basic troubleshooting tips. 4.14 ECU AP Settings This menu can be used if you would like to change the default password of the ECU-R hotspot. Please connect to the ECU hostpot first, open the menu "ECU APP settings" and change the password at your convenience. If doing a reset of the ECU, password will be reinitialized as 88888888. APsystems ECU-R Installation/User Manual 21 4. ECU-R User Interface 4.15 Do-It-Yourself(DIY) Registration This menu is only for DIY installers: it will allow DIY installer to create their EMA account by themselves. They can later on access to their account via the EMA APP. Once the ECU has been properly commissioned, make sure to connect your smartphone or tablet to local internet. Enter "Do it Yourself Registration Menu" and follow instructions to create your own EMA account. . ECU-R User Interface 4.16 Settings This basic menu allows you to change the Language: English, French, Spanish, Portuguese, Polish, Simplified Chinese and traditional Chinese. We're adapting to more languages. APsystems ECU-R Installation/User Manual 22 5. Technical Data For technical data, please refer to the most Up To Date datasheet to APsystems website. 5.1 Disposal Disposal of your old appliance 1. When this crossed-out wheeled bin symbol is attached to a product, it means the product is covered by the European Directive 2002/96/EC. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. 3. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health. 4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. CAUTION The professional person is allowed to replace the battery. Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. This Class B digital apparatus complies with Canadian ICES-003. APsystems ECU-R Installation/User Manual 23 5. Technical Data This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the useris encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. APsystems ECU-R Installation/User Manual 24 6. Contact Information ALTENERGY POWER SYSTEM Inc. www.APsystems.com APsystems Jiaxing China No. 1, Yatai Road, Nanhu District, Jiaxing, Zhejiang Tel: 400-100-8470 Mail: info@apsystems.cn APsystems Shanghai China B305 No. 188, Zhangyang Road, Pudong, Shanghai Tel: 400-100-8470 Mail: info@apsystems.cn APsystems Australia Suite 502, 8 Help Street, Chatswood NSW 2067 Australia Mail: info@altenergy-power.com APsystems America 8701 N. Mopac Expy, Ste 160, Austin, TX 78759 Mail: info@APsystems.com APsystems Europe 244c rue du Point du Jour 01000 Saint Denis lès Bourg, France Mail: emea@APsystems.com Karspeldreef 8, 1101 CJ, Amsterdam, The Netherlands Mail: emea@APsystems.com APsystems Mexico AV. Lazaro Cardenas 2850-5 º Piso, Colonia Jardines del Bosque C.P. 44520, Guadalajara, Jalisco Mail: info.latam@APsystems.com APsystems ECU-R Installation/User Manual 25
![]() |
APsystems ECU-B Installation and User Manual for Solar Monitoring Comprehensive installation and user guide for the APsystems ECU-B, detailing setup, interface, monitoring, and technical specifications for solar energy systems. |
![]() |
APsystems ECU-C Energy Communication Unit Installation and User Manual Comprehensive guide for installing, configuring, and operating the APsystems ECU-C Energy Communication Unit for solar energy monitoring. Covers hardware setup, network connectivity, local and remote management, and technical specifications. |
![]() |
APsystems ECU-C Installation and User Manual for Energy Communication Unit This manual details the installation, operation, and network configuration of the APsystems ECU-C Energy Communication Unit, a key component for monitoring solar energy systems and microinverter performance via the APsystems EMA platform. |
![]() |
APsystems ECU-B Installation and User Manual This manual provides detailed instructions for the installation and use of the APsystems Energy Communication Unit (ECU-B), a gateway for monitoring small PV systems. It covers interface explanations, hardware installation, user interface setup, technical data, and contact information. |
![]() |
APsystems YC1000-3 3-Phase Microinverter: Installation and User Manual Detailed installation and user guide for the APsystems YC1000-3 3-Phase Microinverter. Covers safety instructions, system overview, installation procedures, operation, troubleshooting, technical specifications, and wiring diagrams for solar photovoltaic systems. |
![]() |
APsystems EMA API Operation Manual This operation manual details the APsystems EMA API, a powerful interface designed for third-party users and applications. It enables seamless access to data from APsystems' Energy Monitoring and Analysis (EMA) systems and Energy Control Units (ECUs). Discover how to authenticate, retrieve performance metrics, and integrate with APsystems' solar energy monitoring solutions. The API supports fetching real-time and historical data, including system and ECU output power, as well as meter energy production and consumption across various timeframes. |
![]() |
APsystems DS3 Series Microinverter User Manual and Installation Guide Comprehensive user manual and installation guide for APsystems DS3 series microinverters (DS3-S, DS3-L, DS3) for North America. Covers safety, system introduction, installation procedures, operation, troubleshooting, technical data, and wiring diagrams. |
![]() |
APsystems DS3 Series Microinverter User Manual - Installation & Operation Guide Comprehensive user manual for APsystems DS3-L and DS3 series microinverters. Covers installation procedures, safety instructions, troubleshooting, technical data, and system operation for grid-tied PV systems. |