BRISTAN
Installation Instructions & User Guide
Key Specifications
Product Code: ACR EFSNK Range (D3)
Dynamic Water Pressure: Min: 0.3 bar, Max: 5.0 bar
Inlet Water Temperature: Maximum Hot 65°C
Maximum Static Pressure: 10.0 bar
Inlet Connections: 1/2" BSP Flexible Tails with Isolation Valves, Non-Return Valves Included
Outlet: Housed M22 8lpm Aerator
Tools You'll Need
- Adjustable Spanner
- Hexagonal Keys (2.5 mm, 4 mm)
- EasyFit Tool
Prior to Installation
Please leave these instructions with the end user.
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 and The Water Supply (Water Fittings) (Scotland) Byelaws 2014. For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/servicing purposes.
This product must not be modified in any way as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing. Address: The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791.
Installation
Remove the protective cap from the base assembly.
[Diagram: Base assembly with a protective cap being removed.]
Feed the base through the sink hole from the top. Drop the Plain Inlet Connector into the base. Ensure the flat area of the plain inlet connector is sitting flush adjacent to the threaded inlet connector.
[Diagram: Base being fed through a sink hole, with a plain inlet connector being inserted into the base. Shows the connector's flat side alignment.]
Turn the hexagonal key clockwise until the base is secured. DO NOT OVER-TIGHTEN.
[Diagram: Hexagonal key turning the base assembly clockwise. Text overlay: "DO NOT OVER-TIGHTEN".]
Screw the flexible tails into the base.
[Diagram: Flexible tails being screwed into the base of the tap fitting.]
REMEMBER: Hot on the left, cold on the right. Connect the hot and cold water connections.
[Diagram: Showing connection points for hot and cold water, with labels indicating left for hot and right for cold.]
Grease the O-Rings using the Molykote Grease provided.
[Diagram: Applying Molykote Grease to O-rings.]
Place your desired tap onto the base.
[Diagram: Placing the tap body onto the secured base assembly.]
IMPORTANT: Ensure the tap is correctly positioned and fully located on the base. Secure in place with the grub screws using the tool provided.
[Diagram: Tap body secured to the base with grub screws using the provided tool. Text overlay: "IMPORTANT Ensure the tap is correctly positioned and fully located on the base".]
Thread the hexagonal key through the EasyFit tool and tighten the grub screws with an extra 1/2 turn.
[Diagram: Using the EasyFit tool and hexagonal key to tighten grub screws further.]
Operation: Your tap is now ready to use.
[Diagram: Tap handle in 'Off' position, then moved to 'On' position for Hot and Cold water flow.]
Pack Contents
- 2x Flexible Connecting Pipes (with slight 90° bend angle)
- 1x EasyFit Tool
- 1x Housed M22 8lpm Aerator
- 1x Aerator Housing
- 1x Molykote Grease
- 10x Grub Screws
- 2x Non-Return Valves
- 1x Isolation Valve
Spare Parts
To replace any spare parts for your tap, why not scan the QR code or visit www.bristan.com and search for your product.
[Diagram: QR code mentioned for spare parts and website.]
Alternative Installation for Surfaces Out of Tolerance/Extra Stability
Turn the hexagonal key anti-clockwise to remove the back nut from the EasyFit Base.
[Diagram: Hexagonal key turning anti-clockwise to remove back nut.]
Feed the base through the sink hole from the top.
[Diagram: Base being fed through sink hole.]
REMEMBER: Make sure the base is centralised when viewed from the front of the tap.
[Diagram: Visual guide to centering the base.]
Feed the Reinforcing Plate (if required) and Back nut up to the underside of the sink.
[Diagram: Reinforcing plate and back nut positioned under the sink.]
Turn the hexagonal key clockwise to secure the EasyFit Base. Proceed to Step 4 of the Installation Steps.
[Diagram: Hexagonal key securing the base. Instruction to proceed to step 4 of main installation.]
Maintenance - Replacing Cartridge
IMPORTANT: Isolate the water supply before starting! Remove the handle and spline adapter.
[Diagram: Isolating water supply, then removing tap handle and spline adapter.]
Unscrew the valve to remove it.
[Diagram: Unscrewing the valve component.]
Reverse the steps to replace the valves.
[Diagram: Reassembly steps for replacing valves.]
Maintenance - Cleaning/Replacing Outlet
Unscrew the aerator housing.
[Diagram: Unscrewing the aerator housing.]
Remove the aerator from housing. Clean and replace as necessary.
[Diagram: Removing and cleaning the aerator.]
Secure the aerator. Turn on the mains water supply, letting the water flow for a few minutes to flush through the system.
[Diagram: Re-securing aerator, turning on water, and flushing.]
Troubleshooting
Symptom | Cause(s) | Remedy |
---|---|---|
No flow or low flow rate | Partially closed isolation valve. Head of water is below the minimum distance required. Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous flow rate. Airlock or partial blockage in the supply pipework or hoses. Water supply failure. | Open isolation valve. Refer to your the Specification for the minimum working pressure/distance required. Do not use other water outlets when using the taps. Flush through pipework to ensure removal of debris and any airlocks. Investigate water supply. Check your plumbing and heating systems for any faults. |
Water dripping from taps | This is normal for a short time after using the taps. If water continues to drip, possibly due to the ceramic disc valves/cartridge. | This is caused by residual water tension, the build up of water in the tap body. Refer to the Maintenance section to replace the valves/cartridge. |
Taps do not turn on | Closed isolation valve. Mains water supply turned off. | Open isolation valve. Turn on mains water supply. |
Wobbly Tap | Grub screws are not tight enough at the base. Extra security may be required depending on the surface the tap is fitted on to. | Ensure the grub screws are fully tightened against the base. Refer to the Alternative Installation steps in order to fit the Reinforcing Plate. |
Notes
Please use this space for any notes you or your installer may have regarding the installation/plumbing of this product.
Contact Us
Bristan Group Ltd.
A Masco Company
UK:
Bristan Group,
Pooley Hall Drive,
Birch Coppice Business Park,
Dordon, Tamworth
B78 1SG.
EU:
Masco Europe S.à.r.l.
14 Rue Strachen
6933 Mensdorf
Luxembourg
Email Us: enquire@bristan.com
Website: www.bristan.com
Call Us: +44330 026 6273
[Diagram: Bristan logo mentioned.]
General Cleaning
Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes.
Your tap should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
[Diagram: QR code mentioned for guarantee registration.]