Rheem PERFORMANCE PLATINUM™ Hybrid Electric Heat Pump
The new degree of comfort®
Overview
The PERFORMANCE PLATINUM™ Hybrid Electric Heat Pump is presented as the most efficient water heater available.
Key Features:
- Efficiency: High 3.83 - 4.07 UEF reduces operating cost. [ENERGY STAR Certified].
- Performance: Delivers hot water faster than most standard electric water heaters, with 60-87 gallons first-hour delivery depending on model. Features an ambient operating range of 37-145° F, the widest in its class, offering more heat pump operation annually and designed to meet Northern Climate Spec (Tier 4). Offers Quiet Operation.
- Easy Installation: Universal top and side water connections, quick access to electrical junction box, duct ready design, and easily replaces a standard electric water heater.
- Integration: Electronic control for easy temperature adjustment and mode management. Audible alarm for service alerts. Built-in Wi-Fi powered by [EcoNet Wi-Fi logo] and a free mobile app provides users control over the water heater, allowing for customizable temperature, vacation settings, energy savings, and system monitoring at home or away. Demand Response Ready with built-in EcoPort™ (CTA-2045 Port). Easily add leak detection and prevention with the leak sensor and shut-off valve kit (part# SP21265A sold separately).
Operation Modes
- Energy Saver
- Heat Pump
- High Demand
- Electric
- Vacation/Away: 2-28 days (or placed on hold indefinitely)
Additional Features
- Premium grade anode rod extends the life of the tank.
- Dip tube diffuser reduces sediment, improving efficiency and tank life.
- 3/4" NPT water inlet and outlet; 3/4" condensate drain connections.
- Incoloy stainless steel resistor elements.
- Dry-fire protection.
- Easy access, top mounted washable air filter.
- 2" Non-CFC foam insulation.
- Enhanced flow brass drain valve.
- Temperature and pressure relief valve installed.
- Design certified to NSF/ANSI 372 (Lead Content).
Warranty
10-Year limited warranty for tank and parts, 1-year full in-home labor warranty. See Residential Warranty Certificate for complete information.
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.
Product Details
Model Series: PERFORMANCE PLATINUM Hybrid Electric Heat Pump
Capacities: 40, 50, 65 and 80-Gallon
Electrical: 208-240 Volt / 1 PH 30 Amp
Note: * Wi-Fi broadband internet connection required.
Visual Description: Image shows the Rheem PERFORMANCE PLATINUM Hybrid Electric Heat Pump, highlighting top connections and ducting options. It displays the [ENERGY STAR logo], [UL certification logo], and indicates [LEED Points = 3].
Specifications
Technical Specifications
Fuel Type | Desc. | Nominal Gallon Cap. | Rated Gallon Cap. | Model Number | Electric Breaker Size | Uniform Energy Factor (UEF) | Element Wattage | Compressor Btu/H | First Hr. Rating (Gallons) | Recovery 90° F Rise | Tank Height A | Diam. B | Ht. to Cold Inlet & Drain Valve | Ht. to Hot Outlet & T&P | Unit Wt. (LBS.) | Approx. Ship Wt. (LBS.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electric | Tall | 40 | 36 | XE40T10H45U1 | 30 | 3.83 | 4,500 | 4200 | 60 | 27 | 63" | 20-1/4" | 3-5/8" | 39-5/8" | 166 | 184 |
Electric | Tall | 50 | 45 | XE50T10H45U1 | 30 | 3.88 | 4,500 | 4200 | 67 | 27 | 62" | 22-1/4" | 3-5/8" | 39-5/8" | 185 | 203 |
Electric | Tall | 65 | 59 | XE65T10H45U1 | 30 | 4.05 | 4,500 | 4200 | 76.6 | 27 | 65" | 24-1/4" | 3-7/8" | 42-3/8" | 245 | 289 |
Electric | Tall | 80 | 72 | XE80T10H45U1 | 30 | 4.07 | 4,500 | 4200 | 87 | 27 | 75" | 24-1/4" | 3-7/8" | 42-3/8" | 261 | 306 |
Dimensions
Diagram Description: A schematic illustration of the Rheem Hybrid Electric Heat Pump showing dimensions labeled A through K. A note indicates "2" Clearance Needed for T&P Release".
DESCRIPTION | NOMINAL GALLON CAPACITY | MODEL NUMBER | A | B | C | D | E | F | G | H | I | J | K |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions (in inches) | 40 | XE40T10H45U1 | 62-5/16 | 20-1/4 | 47 | 3-5/8 | 39-5/8 | 23-3/8 | 20-1/2 | 78-7/8 | 20-1/4 | 23-1/4 | 64-15/16 |
Dimensions (in inches) | 50 | XE50T10H45U1 | 61-3/4 | 22-1/4 | 47 | 3-5/8 | 39-5/8 | 25-3/8 | 22-1/2 | 78-5/8 | 22-1/4 | 25-9/16 | 64-3/8 |
Dimensions (in inches) | 65 | XE65T10H45U1 | 64-3/16 | 24-1/4 | 49 | 3-7/8 | 42-3/8 | 27-1/2 | 24-5/8 | 81-1/8 | 24-1/4 | 27-3/8 | 66-13/16 |
Dimensions (in inches) | 80 | XE80T10H45U1 | 74-3/16 | 24-1/4 | 59 | 3-7/8 | 42-3/8 | 27-1/2 | 24-5/8 | 91 | 24-1/4 | 27-3/8 | 76-13/16 |
Installation Guidelines
Hybrid Electric Heat Pump Water Heater Installation Guidelines to Provide Optimal Efficiency
- Heater: Not Ducted (Large Room)
Room size: Larger than 700 ft³ (e.g. 7' x 10' x 10'). Requirements: No additional ventilation needed.
Diagram Description: Illustrates a heater installation in a spacious room where no specific ventilation is required. - Heater: Not Ducted (Small Room)
Room size: Smaller than 700 ft³ (e.g. 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom.
Diagram Description: Depicts a heater in a smaller room, mandating a louvered door or separate louvers for ventilation. - Heater: Not Ducted (Small Closet)
Room: Small Closet. Requirements:- Air gap under door equal to 18 in² (0.75" clearance).
- Louver must be located the same height on door as the air exhaust on heater.
- Heater air exhaust must be positioned towards louver within one foot of door.
Diagram Description: Shows a heater in a closet with precise clearance requirements for the door and air exhaust placement relative to louvers. - Heater: Ducted with inlet OR outlet duct
Room size: Any size room. Requirements: Air gap under door equal to 18 in² (0.75" clearance).
Diagram Description: Illustrates a heater with ductwork connected to either the inlet or outlet, requiring an air gap under the door. - Heater: Ducted with inlet AND outlet duct
Room size: Any size room. Requirements: No additional ventilation needed.
Diagram Description: Shows a heater with ductwork connected to both inlet and outlet, not requiring additional room ventilation.
Important Note: Heat pump water heaters may operate in rooms less than 700 ft³ down to 450 ft³ but with reduced energy efficiency and performance. Rheem Manufacturing has not evaluated this reduced performance, and it is not recommended for optimal unit operation. For small enclosures, a door or wall with a minimum of 2.3 sq ft of louvers is recommended for proper air changes.
Accessories
Hybrid Electric Heat Pump Accessories List
PART NUMBER | DESCRIPTION | USE FOR |
---|---|---|
AP19134 | Leak Sensor | Automatic detection of internal and external leaks |
AS50618A | Shutoff Valve | Automatic shut off of water supply to unit |
SP20882 | Earthquake Isolation Kit | Installations in seismic regions |
SP20883 | Vibration Isolation Kit | Installation on non-concrete floors |
SP20884 | 8" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 8" diameter |
SP20885 | 7" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 7" diameter |
SP20886 | 6" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 6" diameter |
SP20887 | 5" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 5" diameter |
SP20888 | 8" Collar for Flex Venting | Exhaust only to the outside ducting configuration (no inlet duct) |
SP20889 | 25' Flexible 8" Diameter Duct Kit | For up to 25' of ducting |
SP20890 | 8" Rigid Elbow Duct Kit | Installation in tight places where space needs to be minimized |
UPGRADE KIT
PART NUMBER | DESCRIPTION | USE FOR |
---|---|---|
SP21265A | Kit - Automatically Shutoff Valve Assembly | Add leak detector, shutoff valve and S.O.V extension harness for top connection setup |
Accessory Visual Descriptions: Images are provided for the following accessories: Leak Sensor, Shutoff Valve, Earthquake Isolation Kit, Vibration Isolation Kit, 8" Diameter UL Certified Termination Kit, 7" Diameter UL Certified Termination Kit, 6" Diameter UL Certified Termination Kit, 5" Diameter UL Certified Termination Kit, 8" Collar for Flex Venting, 25' Flexible 8" Diameter Duct Kit, and 8" Rigid Elbow Duct Kit. An image also depicts the "Leak Sensor & Shutoff Valve Kit" for the UPGRADE KIT.