Image of the Inkbird ITC-100 PID Temperature Controller. It features a black casing with a dual-line LED display showing 'TEMPERATURE', 'PV' (Process Value), 'SV' (Set Value), and status indicators like 'OUT', 'AL 1', 'AL 2', 'RUN', 'AT/RUN'. Below the display are control buttons labeled 'ITC', 'SET', and directional arrows.

INKBIRD

Inkbird Tech. Co., Ltd.

Copyright

Copyright© 2016 Inkbird Tech. Co., Ltd. All rights reserved. No part of this document may be reproduced without prior written permission.

Disclaimer

Inkbird has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Please contact Inkbird to ensure you have the latest version of this document.

1. Safety Precautions

2. Specification

Mounting dimension

Main Features

2. Specification (Continued)

Attribute Details
Units Degree Celsius (<1000°C)
Weight Approx. 140g
Power Supply Voltage AC 100-240V ±10% 50/60Hz
AC/DC 12-24V ±10% 50/60Hz
DC 12-24V ±10%
Operating voltage range 85~110% Rated voltage
Power Consumption Approx. 5VA (100~240VAC)
Approx. 4VA (12~24VAC)
Approx. 3W (12~24VDC)
Display Character PV: 4 digital 9.9mm height Red LED Letters
SV: 4 digital 8mm height Green LED Letters
Display Accuracy ±0.2%FS 0.1°C (<1000°C); 1°C (≥1000°C)
Period of Sampling 0.5S
Temperature Compensation 0-50°C
Main Output Relay Contact Output (ITC-100R):
AC250V 3A (Resistive load) ON/NC.
Alarm 1 AC250V 3A (Resistive load) ON/NC.
Voltage Pulses Output (ITC-100V):
DC 12V, 30mA;
Alarm 1 AC250V 3A (Resistive load) ON/NC
Life Expectancy of Relay Mechanical ≥10,000,000 operations
Electrical ≥10,000,000 operations
Storage Temperature -25~65°C (no icy or condensation)
Data Storage 10 year
Mounting Method Flush mounting and screw terminals
Environmental Conditions -10~55°C (no icy or condensation), RH 35-85% Humidity

3. Connection

3.1 Dimension (unit: mm)

Shell Diagram: A rectangular diagram showing dimensions: Height 89mm, Width 74mm, Depth (indicated by X) 48mm.

Mounting bracket Diagram: A diagram showing a bracket with dimensions: Length 49mm, Width (indicated by X) 56mm.

Panel Cutout Diagram: A diagram showing the required panel cutout dimensions: Minimum 60mm for width and height, with a cutout size of 45+0.6mm for width and 45+0.6mm for height.

3.2 Connection

ITC-100V Connection Diagram: Shows terminals numbered 1 through 12. Terminal 1 (NC), 6 (NO), 11 (SSR Output). Terminal 3 (TC-), 8 (Output+). Terminal 4 (AL1), 9 (AL1). Terminal 5 (COM), 12 (Power). Terminal 10 (COM). Connections are shown to SSR and Power.

ITC-100R Connection Diagram: Shows terminals numbered 1 through 12. Terminal 1 (NC), 6 (NO), 11 (SSR Output). Terminal 3 (TC-), 8 (Output+). Terminal 4 (AL1), 9 (AL1). Terminal 5 (COM), 12 (Power). Terminal 10 (COM). Connections are shown to SSR and Power.

4. Front Panel and Operation

Front Panel Diagram Description: The front panel features a large LED display area showing 'TEMPERATURE' and two rows of numerical displays (PV and SV). Status indicator LEDs are labeled 'OUT', 'AL 1', 'AL 2', 'RUN', 'AT/RUN'. Below the display are control buttons: 'ITC', 'SET', and directional arrows: '◀' (Left/Shift), '▶' (Right/Move), '▲' (Up), '▼' (Down).

The buttons are numbered 1 through 7:

5. Operation Process

5.1 Input Type (Table1)

Input Type Input Value Measuring Range
Thermocouple K 0 -50~1300°C
S 1 -50~1700°C
Wr 2 -0~2300°C
T 3 -2000~350°C
E 4 0~1000°C
J 5 0~1000°C
B 6 0~1800°C
N 7 0~1300°C
Cu resistance CU50 20 -50~150°C
Platinum resistance PT100 21 -200~600°C

5.2 Alarm Function Setting (Table 2)

Alarm Output Alarm Type ALP Value
AL1 Output Upper Alarm Limit 0
Lower Alarm Limit 0
Maximum Deviation Alarm 0
Minimum Deviation Alarm 0
AL2 Output Upper Alarm Limit 1
Lower Alarm Limit 2
Maximum Deviation Alarm 4
Minimum Deviation Alarm 8

5.3 Error Display (Fault Diagnosis)

SV Display Explain Remedy
orAL (orAL) Input Sensor Selected Error Input the correct value consistent with parameters of sensor.
Signal Wire Connected Error Correct the Connecting Signal Wire.
(orAL) Sensor Fault Check the sensor.

6. Operating Instruction

7. Parameter Setting and Defining

After power-on, press and hold the [SET] key for more than 2 seconds to enter setting mode. Use the [Up Arrow] or [Down Arrow] keys to set the value. After finishing, press the [SET] key to confirm and proceed to the next function setting. The PV/SV screen will return to normal display after setting.

Note: If modifications are made in setting mode, the instrument will automatically save the current value after more than 10 seconds of inactivity and return to normal status.

Function Setting Code Name Description Setting Range Unit Remarks Factory Default
HI AL HIAL Upper Alarm Limit -1999~+9999 1°C 9999
LoAL LOAL Lower Alarm Limit -1999~+9999 1°C -1999
dH AL dHAL Maximum Deviation Alarm 0~9999 1°C 9999
dL AL dLAL Minimum Deviation Alarm 0~9999 1°C 9999
dF dF Hysteresis 0~200.0 0.1°C 0.3
CtrL Ctrl Control Output 0: ON/OFF
1/3: PID
2: Self-adjustment
3
" M50 M50 Integral 0~9999 0.1°C 0: Cancel 1000
" P P Differential 0~9999 0.01S/°C 500
" t t Hysteresis Time 1~9999 S 120
" CEI Ctl Control Period 1~120 S 4
" 5n Sn Input Sensor 0~42 Table 1 0

7. Parameter Setting and Defining (Continued)

Function Setting Code Name Description Setting Range Unit Remarks Factory Default
di P dip Decimal Point Position 0~3 1
di L diL Input Lower Limit Value -1999~+9999 1 Digital 0
di H diH Input Upper Limit Value -1999~+9999 1 Digital 1000
SC SC Sensor Calibration -199~+999 0
oP1 OP1 Output Mode 0/2: Time Duty
1: 0-10mA
0
OPL Opl Output Lower Limit 0~220 1% 0
OPH Oph Output Upper Limit 0~220 1% 100
ALP ALP Alarm Function 0~31 Table 2 0
CF CF System Function 2: Heater
3: Cooler
2
Addr Addr Address 0~63 1
bRud Baud Baud Rate 0~4800 Filter Effect 9600
dL dl Input Digital Filter 0~20 0
run run Run Mode 0: Manual
1: Automatoc
2: No Manual
2
Loc LOC Lock Function 0~999 40
EP1 ~ EP8 8 User-defined Parameters Select any Parameter from this Table Except LOC and EP1~EP8 none

User-defined Parameter

In the process of setting parameters, the display modes of the last eight parameters differ from the previous ones. The PV screen displays the prompt EP1 - EP8. The SV screen displays various prompts of technical parameters (e.g., HiAL, LoAL, dHAL, and so on). Press the [Up Arrow] or [Down Arrow] key. The technical parameters in the SV screen will be listed in proper order as in the table above. After that, press the [SET] key to confirm and enter the next setting. "none" needs to be set if the user does not need to use the user-defined parameter. Press the [SET] key to set these 8 user-defined parameters until all are set, and then return to normal status.

Datalock (LOC)

When the setting values of LOC are not "2", "40", or "808", the instrument only allows setting 0-8 self-defined parameters and LOC parameters themselves. User can set all parameters only when the LOC value is "2", "40", or "808". Details are as follows:

8. Technical Assistance and Warranty

8.1 Technical Assistance

If you encounter any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. For assistance, please write to cs@ink-bird.com. Emails will be replied to within 24 hours from Monday through Saturday. You can also visit the Inkbird website at www.ink-bird.com to find answers to common technical questions.

8.2 Warranty

INKBIRD TECH. C.L. warrants this thermostat for one year from the date of purchase when operated under normal conditions by the original purchaser (not transferable), against defects caused by INKBIRD's workmanship or materials. This warranty is limited to the repair or replacement, at INKBIRD's discretion, of all or part of the thermostat. The original receipt is required for warranty purposes.

INKBIRD is not responsible for injury, property damage, or other consequential damages or damages of third parties arising directly from actual or alleged defects in workmanship of the product. There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than herein contained in the sale of goods act or any other statute.

Contact Us

Business Contact: sales@ink-bird.com

Technical Support: cs@ink-bird.com

Business Hours: 09:00-18:00 (GMT+8) from Monday to Friday

URL: www.ink-bird.com

PDF preview unavailable. Download the PDF instead.

Inkbird-ITC-100-spec-sheet PDFium PDFium

Related Documents

Preview Inkbird ITC-100 PID Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-100 PID Temperature Controller. Covers safety precautions, specifications, connection diagrams, front panel operation, input types, alarm settings, error diagnosis, parameter configuration, and warranty information.
Preview INKBIRD ITC-608T Temperature and Humidity Controller User Manual
This user manual provides comprehensive instructions for the INKBIRD ITC-608T, a versatile digital controller designed for precise environmental management. It guides users through setup and operation for single temperature, dual temperature, programmable temperature, and humidity control applications.
Preview Inkbird ITC-100 PID Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-100 PID Temperature Controller, covering specifications, connection, operation, parameter settings, and technical support. Includes details on input types, alarm functions, error diagnosis, and warranty information.
Preview INKBIRD ITC-608T Smart Temperature Controller User Manual
Comprehensive user manual for the INKBIRD ITC-608T smart temperature and humidity controller. This guide covers setup, operation, specifications, and technical assistance for various control modes.
Preview Inkbird IHC-200 WIFI Humidity Controller Internal Equipment Photographs
Detailed internal equipment photographs of the Inkbird IHC-200 WIFI Humidity Controller, showcasing its internal circuit boards, components, and wireless module. The device is identified by FCC ID 2AYZD-200WIFI and IC 30368-200. Key components include relays, microcontrollers, and a WBR3 Wi-Fi module.
Preview Inkbird ITC-1000F All-Purpose Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-1000F All-Purpose Temperature Controller, detailing specifications, wiring diagrams, operational instructions, menu settings, error codes, and warranty information. Essential guide for installation and use.
Preview INKBIRD IHC-200-WIFI Humidity Controller User Manual
Detailed user manual for the INKBIRD IHC-200-WIFI Humidity Controller, covering features, specifications, Wi-Fi setup, settings, operations, alarms, safeguards, and warranty information.
Preview INKBIRD ITC-308-WIFI Smart Temperature Controller User Manual
This user manual provides detailed instructions for setting up and operating the INKBIRD ITC-308-WIFI smart temperature controller, including specifications, app integration, control functions, and troubleshooting.