1. Safety Precautions

  • Ensure the product is used within its specifications.
  • Do not touch terminals while power is supplied, as this may cause electric shock.
  • Prevent metal pieces, wire clippings, or filings from entering the product to avoid electric shock, fire, or malfunction.
  • Do not use the product in environments with flammable or explosive gas to prevent explosion injuries.
  • Never disassemble, modify, or repair the product, or touch internal parts, to avoid electric shock, fire, or malfunction.
  • Be aware that output relays may experience fusing or burning past their life expectancy. Always consider application conditions and use relays within their rated load and electrical life expectancy.

2. Specification

Main features

  • Fahrenheit and Celsius display options.
  • User-friendly operation.
  • Switchable between Cooling and Heating Modes.
  • Temperature control via Set Value and Difference Value.
  • Temperature Calibration.
  • Refrigerating Control Output Delay Protection.
  • Alarm for temperature exceeding limits or sensor errors.

Mounting dimension

  • Front Panel Size: 75(L) * 34.5(W) mm
  • Mounting Size: 71(L) * 29(W) mm
  • Product Size: 75(L) * 34.5(W) * 85(D) mm
  • Sensor Length: 2m (includes probe)

Technical Specifications

ParameterValue
Temperature Measuring Range-50~210 °F / -50 °C~99 °C
Resolution0.1 °F / 0.1 °C
Measuring Accuracy±1 °F (-50 °F -160 °F) / ±1 °C (-50 °C -70 °C)
Power Supply110Vac/220Vac 50Hz/60Hz, 12Vdc
Power Consumption<3W
SensorNTC Sensor
Relay Contact CapacityCooling (10A/250VAC) / Heating (10A/250VAC)
Ambient Temperature0 °C - 60 °C
Storage Temperature-30 °C - 75 °C
Relative Humidity20-85% (No Condensate)
Warranty1 Year

3. Wiring Diagram

3.1 ITC-1000F-110V

Diagram Description: Shows connections for a 110VAC power supply to terminals 1 and 2. Terminals 3 and 4 are for heating (10A/110VAC), and terminals 5 and 6 are for cooling (10A/110VAC). A sensor is connected to terminals 7 and 8.

Notes:

  • Strictly distinguish interface of relay, sensor, and power.
  • Strictly distinguish connection of sensor and power.
  • Sensor down-lead and power wire should be kept a proper distance.

3.2 ITC-1000F-220V

Diagram Description: Shows connections for a 220VAC power supply to terminals 1 and 2. Terminals 3 and 4 are for heating (10A/220VAC), and terminals 5 and 6 are for cooling (10A/220VAC). A sensor is connected to terminals 7 and 8.

Notes:

  • Strictly distinguish interface of relay, sensor, and power.
  • Strictly distinguish connection of sensor and power.
  • Sensor down-lead and power wire should be kept a proper distance.

3.3 ITC-1000F-12V

Diagram Description: Shows connections for a 12V power supply to terminals 1 and 2. Terminals 3 and 4 are for heating, and terminals 5 and 6 are for cooling. The sensor is connected to terminals 7 and 8.

Notes:

  • Strictly distinguish interface of relay, sensor, and power.
  • Strictly distinguish connection of sensor and power.
  • Sensor down-lead and power wire should be kept a proper distance.

4. Keys Instruction

Power Key: Power On and Off, Confirm Setting Value, Save and Exit Function.

Up Key (▲): Choose Parameter, Increase Value and Check the Setting Temperature Value.

Down Key (▼): Choose Parameter, Decrease Value and Check the Setting Difference Value.

Set Key (S): Entry, Exit and Set Parameters.

C/F Display: Shows temperature in Degrees Celsius or degrees Fahrenheit.

PV/SV Display: Displays Process Value, Set Value, and Parameter Menu.

Heat Indicator Lamp: On: Heating Start, Off: Heating Stop.

Set Indicator Lamp (Left lamp): On: Parameter Setting Status.

Cool Indicator Lamp (Right lamp): On: Refrigerating Start, Off: Refrigerating Stop, Flash: Compressor Delay Protection.

5. Key Operation Instruction

5.1 Check Parameter

In normal working status, press the Up Key (▲) once to display the setting temperature value; press the Down Key (▼) once to display the difference value.

5.2 Parameter Setting

In normal working status, press and hold the Set Key (S) for more than 3 seconds to enter set mode. The set indicator lamp will turn on, and the screen will display the first menu code "TS".

Press the Up Key (▲) or Down Key (▼) to move up or down the menu item and display the menu code.

Press the Set Key (S) to enter the parameter setting of the current menu; the parameter value will start to flash.

Press the Up Key (▲) or Down Key (▼) to adjust the parameter value of the current menu.

After setting, press the Set Key (S) to exit the parameter setting of the current menu; the parameter value will stop flashing. User can set other functions as above steps.

In any status, press the Power Key (ON/OFF) to save the parameter modified value and return to the normal temperature display.

If no operation occurs within 10 seconds, the system will automatically exit the menu and return to the normal temperature display status, without saving the modification.

5.3 Operating Instruction

In normal working status, press and hold the Power Key (ON/OFF) for more than 3 seconds to turn off the controller; in Power-off Status, press and hold the Power Key (ON/OFF) for more than 1 second to turn on the controller.

In normal working status, the screen displays the current measuring value, and the controller automatically switches between heating and cooling modes.

Cooling Mode: If the measuring temperature ≥ temperature set value + difference set value, the controller starts refrigerating. The cool indicator lamp lights on, and the refrigerating relay is connected. If the cool indicator lamp flashes, it indicates the refrigerating device is under compressor delay protection.

If the measuring temperature ≤ temperature set value, the cool indicator lamp turns off, and the refrigerating relay is disconnected.

Heating Mode: If the measuring temperature ≤ temperature set value - difference set value, the controller starts heating. The heat indicator lamp lights on, and the heating relay is connected.

If the measuring temperature ≥ temperature set value, the heat indicator lamp turns off, and the heating relay is disconnected.

6. Menu Instruction

6.1 When the set temperature is degrees Celsius (°C)

CodeFunctionSet rangeDefaultNote
TSTemperature Set Value-50~99.9 °C10.0 °C
DSDifference Set Value0.3~15 °C1.0 °C
PTCompressor Delay0~10 minutes3 minutes
CATemperature Calibration Value-15 °C~15 °C0 °C
CFFahrenheit or Celsius SettingC

6.2 When the set temperature is degrees Fahrenheit (°F)

CodeFunctionSet rangeDefaultNote
TSTemperature Set Value-50~210 °F50 °FMin. Unit 1 °F
DSDifference Set Value1~30 °F3 °F
PTCompressor Delay0~10 minutes3 minutes
CATemperature Calibration Value-15~15 °F0 °F
CFFahrenheit or Celsius SettingF

Note: When CF value changes, all set values restore to default.

7. Error Description

Sensor Error Alarm

When the temperature sensor circuit is short-circuited or open-circuited, the controller enters sensor error mode and closes all running status. The buzzer alarm sounds, and the screen displays "ER". Press any key to cancel the buzzer alarm. The system returns to normal working status after the error is cleared.

Over-temperature Alarm

When the measured temperature exceeds the temperature measuring range, the controller enters over-temperature error alarm mode and closes all running status. The buzzer alarm sounds, and the screen displays "HL". Press any key to cancel the buzzer alarm. The system returns to normal working status after the temperature returns to the measuring range.

8. Technical Assistance and Warranty

8.1 Technical Assistance

If you encounter any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. For assistance, please write to cs@ink-bird.com. Emails will be replied to within 24 hours from Monday through Saturday.

You can also visit the website www.ink-bird.com to find answers to common technical questions.

8.2 Warranty

INKBIRD TECH. C.L. warrants this thermostat for one year from the date of purchase, provided it is operated under normal conditions by the original purchaser (not transferable). This warranty covers defects caused by INKBIRD's workmanship or materials and is limited to repair or replacement, at INKBIRD's discretion, of all or part of the thermostat. The original receipt is required for warranty purposes.

INKBIRD is not responsible for injury, property damage, or other consequential damages arising directly from actual or alleged defects in workmanship of the product.

There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than those contained herein, as per the sale of goods act or any other statute.

Contact Information

Business Contact: sales@ink-bird.com

Technical Support: cs@ink-bird.com

Business Hours: 09:00-18:00 (GMT+8) from Monday to Friday

URL: www.ink-bird.com

Inkbird Tech. Co., Ltd.

Inkbird-ITC1000F-User-Manual My Name

Related Documents

Preview INKBIRD ITC-308-WIFI Smart Temperature Controller User Manual
This user manual provides detailed instructions for setting up and operating the INKBIRD ITC-308-WIFI smart temperature controller, including specifications, app integration, control functions, and troubleshooting.
Preview Inkbird ITC-2000 Alarm & Relay Output Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-2000 temperature controller, covering safety precautions, specifications, wiring diagrams, key operations, menu settings, error handling, and warranty information. Designed for precise temperature control in various applications.
Preview INKBIRD ITC-306A Smart Wi-Fi Temperature Controller for Aquarium - User Manual
Comprehensive user manual for the INKBIRD ITC-306A Smart Wi-Fi Temperature Controller, detailing features, setup, operation, troubleshooting, and technical specifications for aquarium use. Learn how to connect via Wi-Fi, set temperature controls, and manage alarms.
Preview Inkbird ITC-1000F All-Purpose Temperature Controller User Manual
User manual for the Inkbird ITC-1000F All-Purpose Temperature Controller, detailing specifications, wiring, operation, menu settings, error handling, and warranty information.
Preview Inkbird ITC-100 PID Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-100 PID Temperature Controller. Covers safety precautions, specifications, connection diagrams, front panel operation, input types, alarm settings, error diagnosis, parameter configuration, and warranty information.
Preview INKBIRD ITC-308 WiFi Temperature Controller for Cooling and Heating
Detailed specifications and features of the INKBIRD ITC-308 WiFi dual-relay temperature controller for cooling and heating applications, including technical data and warranty information.
Preview Inkbird ITC-308 Plug and Play Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-308 Plug and Play Temperature Controller. Covers product overview, detailed specifications, key functions, operational instructions, menu settings, error codes, and warranty information.
Preview Inkbird ITC-100 PID Temperature Controller User Manual
Comprehensive user manual for the Inkbird ITC-100 PID Temperature Controller, covering specifications, connection, operation, parameter settings, and technical support. Includes details on input types, alarm functions, error diagnosis, and warranty information.