Provided by ManualsAndMore.com

Download PDF User Manual

Inkbird ITC-1000F User Manual - User Manual - PDF Download

PDF preview unavailable. Download the PDF instead.

Inkbird-ITC1000F-User-Manual
All-Purpose Temperature Controller
ITC-1000F User Manual
Version 1.0s
Inkbird Tech. Co., Ltd.
Copyright Copyright© 2016 Inkbird Tech. Co., Ltd. All rights reserved. No part of this document may be reproduced without prior written permission. Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Please contact Inkbird to ensure you have the latest version of this document.

ITC-1000 User Manual
Contents
1. Safety Precautions ................................................................................................3 2. Specification ........................................................................................................4
Main features .....................................................................................................4 Mounting dimension ............................................................................................4 3. Wiring Diagram ....................................................................................................5 3.1 ITC-1000F-110V ...........................................................................................5 3.2 ITC-1000F-220V ...........................................................................................5 3.3 ITC-1000F-12V .............................................................................................5 4. Keys Instruction ...................................................................................................6 5. Key Operation Instruction ......................................................................................6 5.1 Check Parameter...........................................................................................6 5.2 Parameter Setting .........................................................................................6 5.3 Operating instruction .....................................................................................7 6. Menu Instruction ..................................................................................................8 6.1 When the set temperature is degrees Celsius (FCC) ........................................8 6.2 When the set temperature is degrees Fahrenheit (FCF) ...................................8 7. Error Description ..................................................................................................9 Sensor Error Alarm .............................................................................................9 Over-temperature Alarm......................................................................................9 8. Technical Assistance and Warranty ....................................................................... 10 8.1 Technical Assistance .................................................................................... 10 8.2 Warranty .................................................................................................... 10

Inkbird Tech. Co., Ltd. 2

www.ink-bird.com

1. Safety Precautions

ITC-1000 User Manual

 Ensure the product using within the specification.  Do not touch the terminals at least while power is being supplied. Doing so may
occasionally result in injury due to electric shock.  Do not allow pieces of metal, wire clippings, or fine metallic shaving or filings from
installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction.  Do not use the product where subject to flammable or explosive gas. Otherwise, injury from explosion may occasionally occur.  Never disassemble, modify or repair the product or touch any of the internal parts. Electric Shock, fire, or malfunction may occasionally occur.

If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. The life expectancy of output relays varies considerably with the output load and switch conditions.

Inkbird Tech. Co., Ltd. 3

www.ink-bird.com

2. Specification

ITC-1000 User Manual

Main features
 Fahrenheit and Celsius Display Can Be Choose;  More User-friendly Operating;  Switch Between Cooling and Heating Modes;  Control the Temperature by Setting the Temperature Set Value and the Difference
Value;  Temperature Calibrating;  Refrigerating Control Output Delay Protection;  Alarm When Temperature Exceeds the Limit or When Sensor Error;

Mounting dimension:
 Front Panel Size: 75(L)*34.5(W)mm  Mounting Size: 71(L)*29(W)mm  Product Size75(L)*34.5(W)*85(D)mm  Sensor Length: 2m (include the probe)

Temperature Measuring Range Resolution
Measuring Accuracy Power Supply
Power Consumption Sensor
Relay Contact Capacity Ambient Temperature Storage Temperature
Relative Humidity Warranty

-50210 oF / -50 oC-99 oC 0.1 oF / 0.1 oC
±1 oF-50 oF -160 oF/ ±1 oC-50 oC -70 oC 110Vac/220Vac 50Hz/60Hz, 12Vdc <3W NTC Sensor
Cooling (10A/250VAC)/ Heating (10A/250VAC) 0 oC - 60 oC
-30 oC - 75 oC 20-85% (No Condensate)
1 Year

Inkbird Tech. Co., Ltd. 4

www.ink-bird.com

3. Wiring Diagram
3.1 ITC-1000F-110V

ITC-1000 User Manual

Note:  Strictly distinguish interface of relay,sensor and power  Strictly distinguish connection of sensor and power  Sensor down-lead and power wire should be kept a proper distance
3.2 ITC-1000F-220V

Note:  Strictly distinguish interface of relay,sensor and power  Strictly distinguish connection of sensor and power  Sensor down-lead and power wire should be kept a proper distance
3.3 ITC-1000F-12V

Note:  Strictly distinguish interface of relay,sensor and power
 Strictly distinguish connection of sensor and power
 Sensor down-lead and power wire should be kept a proper distance

Inkbird Tech. Co., Ltd.

www.ink-bird.com

5

4. Keys Instruction

ITC-1000 User Manual

5. Key Operation Instruction

5.1 Check Parameter:
In normal working status, press " " key once, it will display the setting temperature value; press " " key once, it will display the difference value;

5.2 Parameter Setting:
In normal working status, keep pressing " " for more than 3s to enter set mode, set indicator lamp is on, screen displays the first menu code "TS". Press " " key or " " key to move up or down the menu item and display the menu code. Press " " key to enter the parameter setting of current menu, the parameter value starts to flash. Press " " key or " " key to adjust the parameter value of current menu. After the set, press " " key to exit the parameter setting of current menu, the parameter value stops to flash. User can set the other functions as above steps.

In any status, press " " key to save the parameter modified value, and return to the normal temperature value.

Inkbird Tech. Co., Ltd.

www.ink-bird.com

6

ITC-1000 User Manual
If no operating within 10s, it will exit the menu automatically and return to normal temperature display status, and does not save the parameter of this modification.
5.3 Operating instruction:
In normal working status, press and hold " " key for more than 3s to turn off the
controller; in Power-off Status, press and hold " " key for more than 1s to turn on the controller. In normal working status, screen displays the current measuring value, the controller switch modes between heating and cooling automatically. If the measuring temperature  temperature set value + difference set value, the controller starts refrigerating, the cool indicator lamp lights on, and the refrigerating relay is connected. When cool indicator lamp flashes, indicating that the refrigerating device is under compressor delay protecting status. If the measuring temperature  temperature set value, the cool indicator lamp turns off, and the refrigerating relay is disconnected. If the measuring temperature  temperature set value - difference set value, the controller starts heating, the heat indicator lamp lights on, and the heating relay is connected. If the measuring temperature  temperature set value, the heat indicator lamp turns off, and the heating relay is disconnected.

Inkbird Tech. Co., Ltd. 7

www.ink-bird.com

6. Menu Instruction

ITC-1000 User Manual

6.1 When the set temperature is degrees Celsius (FCC)

Code TS DS

Function Temperature Set Value
Difference Set Value

Set range -5099.9 oC
0.315 oC

Default 10.0 oC 1.0 oC

PT

Compressor Delay

010 minutes

3munites

CA

Temperature Calibration Value

-15 oC15 oC

0 oC

CF

Fahrenheit or Celsius Setting

C

Note

6.2 When the set temperature is degrees Fahrenheit (FCF)

Code TS DS

Function Temperature Set Value
Difference Set Value

Set range -50210 oF
130 oF

Default 50 oF 3 oF

Note Min. Unit 1 oF

PT

Compressor Delay

010 minutes 3 minutes

CA

Temperature Calibration Value

-1515 oF

0 oF

CF

Fahrenheit or Celsius Setting

F

Note: When CF value change, all the set values restore to default value.

Inkbird Tech. Co., Ltd. 8

www.ink-bird.com

7. Error Description

ITC-1000 User Manual

Sensor Error Alarm: When the temperature sensor circuit is short circuit or open
circuit, the controller starts sensor error mode and closes all running status, the buzzer alarm sounds, screen displays ER. Press any keys can cancel buzzer alarm, the system returns to the normal working status after error is cleared.

Over-temperature Alarm: When the measuring temperature exceeds the
temperature measuring range, the controller starts over-temperature error alarm mode and closes all running status, the buzzer alarm sounds, screen displays HL. Press any keys can cancel buzzer alarm, the system returns to the normal working status after the temperature returns to measuring range.

Inkbird Tech. Co., Ltd. 9

www.ink-bird.com

ITC-1000 User Manual
8. Technical Assistance and Warranty
8.1 Technical Assistance
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please write us to cs@ink-bird.com. We will reply your emails in 24 hours from Monday through Saturday. You can also visit our web site www.ink-bird.com to find the answers of the common technical questions.
8.2 Warranty
INKBIRD TECH. C.L. warrants this thermostat for one years from the date of purchase when operated under normal condition by the original purchaser (not transferable), against defects caused by INKBIRD's workmanship or materials. This warranty is limited to the repair or replacement, at INKBIRD's discretion, of all or part of the thermostat. The original receipt is required for warranty purposes. INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising directly from an actual or alleged in mater of workmanship of the product. There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than herein contained in the sale of goods act or any other statue.

Contact Us Business Contact: sales@ink-bird.com
Technical Support: cs@ink-bird.com Business Hours: 09:00-18:00(GMT+8) from Monday to Friday
URL: www.ink-bird.com

Inkbird Tech. Co., Ltd. 10

www.ink-bird.com


My Name