S&P Acoustic Cabinet Fans CHAT-N Series

Product Overview

Image shows a S&P CHAT-N Series acoustic cabinet fan, a rectangular unit with a metal casing, visible internal motor, and circular air inlet/outlet flanges.

The S&P CHAT-N Series comprises direct-driven backward curved centrifugal cabinet fans engineered for smoke extraction in fire conditions, certified to F400-120 (CE marked). The fan casings are constructed from a robust galvanized frame combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). All models are equipped with F400-120 rated motors designed for continuous operation (S1) and emergency situations (S2). Depending on the model, these fans are available with three-phase motors in 4, 6, or 4/8 poles.

Key Features

Specific Applications

These fans are officially approved to EN12101-3 standard (Certificate n° 0370-CPR-2475) and are suitable for:

Technical Characteristics

Before installation, verify that the product's electrical characteristics (voltage, power, frequency, etc.) listed on the data plate label match the intended electrical supply.

General Specifications

Model Speed (rpm) Motor power (kW) Nominal current (A) Maximum airflow (m³/h) Sound pressure level (dB(A)) at 1.5 m* Weight (kg) Speed controller
Outlet Inlet Radiated
4 POLE
CHAT/4-400 N 1420 0,37 0,87 3.380 53 54 46 80 VFTM TRI 0,37
CHAT/4-450 N 1410 0,55 1,38 4.770 57 58 50 90 VFTM TRI 0,55
CHAT/4-500 N 1430 1,1 2,4 6.940 60 61 53 110 VFTM TRI 1,1
CHAT/4-560 N 1425 1,5 3,26 9.500 63 65 57 185 VFTM TRI 1,5
CHAT/4-630 N 1410 3 6,17 13.900 67 68 60 200 VFTM TRI 3
CHAT/4-710 N 1460 5,5 10,5 19.570 70 72 64 215 VFTM TRI 5,5
6 POLE
CHAT/6-560 N 910 0,55 1,49 6.370 54 55 47 185 VFTM TRI 0,55
CHAT/6-630 N 925 1,1 2,78 9.320 58 59 51 200 VFTM TRI 1,1
CHAT/6-710 N 940 1,5 3,71 13.320 61 62 54 215 VFTM TRI 1,5
CHAT/6-800 N 960 3 7,3 18.950 65 66 58 229 VFTM TRI 3
4/8 POLE*
CHAT/4/8-450 N 1430/715 0,55/0,09 1,7/0,84 4.770/2.380 57 58 50 90 -
CHAT/4/8-500 N 1430/720 1,1/0,18 2,73/1,21 6.940/3.490 60 61 53 110 -
CHAT/4/8-560 N 1425/720 1,5/0,25 3,65/1,6 9.500/4.800 63 65 57 185 -
CHAT/4/8-630 N 1410/705 3/0,55 6,29/2,35 13.900/6.950 67 68 60 200 -
CHAT/4/8-710 N 1475/735 5,5/1,1 11,7/3,7 19.570/9.750 70 72 64 215 -

* CHAT fans fitted with 2-speed motors are ErP no compliant.

Dimensions

The following diagrams illustrate the physical dimensions of the CHAT-N series fans. The diagrams show front and side views, with dimensions labeled A through L.

Model A B C D E F G H J K L
CHAT/-400 N 650 780 754 400 65 125 104 300 45 40 386
CHAT/-450 N 650 760 754 448 55 101 104 300 45 40 386
CHAT/-500 N 800 910 904 498 55 151 104 375 45 40 461
CHAT/-560 N 860 970 964 558 55 151 104 405 45 40 470
CHAT/-630 N 980 1090 1084 628 55 176 104 465 45 40 530
CHAT/-710 N 1037 1147 1141 708 55 164,5 104 493,5 45 40 558,5
CHAT/-800 N 1200 1310 1304 798 55 201 104 575 45 40 640

Performance Curves

The following sections present performance curves for the CHAT-N series fans, detailing their operational characteristics. These curves are generated in accordance with ISO 5801.

Each set of curves includes:

Performance curves are provided for 4-pole motors (covering models CHAT/4-400 N to CHAT/4-710 N) and 6-pole motors (covering models CHAT/6-560 N to CHAT/6-800 N).

Acoustic Characteristics

This section details the sound power level spectrum in dB(A) for the CHAT-N series fans across various frequency bands (63 Hz to 8000 Hz). Data is provided for Inlet, Outlet, and Radiated sound levels for different models.

Model 63 125 250 500 1000 2000 4000 8000 LWA
CHAT/4-400 N
INLET 1 435763656367595272
INLET 2 405862636160555169
INLET 3 426162646261575370
OUTLET 1 495559616868615373
OUTLET 2 435256586460544967
OUTLET 3 495556586460544968
RADIATED 1 354955575559514464
RADIATED 2 325054555352474361
RADIATED 3 345354565453494562
CHAT/4-450 N
INLET 1 476167696771635675
INLET 2 446266676564595572
INLET 3 466566686665615774
OUTLET 1 535963657272655776
OUTLET 2 475660626864585371
OUTLET 3 535960626864585371
RADIATED 1 395359615963554867
RADIATED 2 365458595756514764
RADIATED 3 385758605857534966
CHAT/4-500 N
INLET 1 516571737175676079
INLET 2 486670716968635976
INLET 3 506970727069656177
OUTLET 1 576367697676696180
OUTLET 2 516064667268625775
OUTLET 3 576364667268625775
RADIATED 1 435763656367595271
RADIATED 2 405862636160555168
RADIATED 3 426162646261575369
CHAT/4-560 N
INLET 1 546874767478706382
INLET 2 516973747271666279
INLET 3 537273757372686480
OUTLET 1 606670727979726483
OUTLET 2 546367697571656078
OUTLET 3 606667697571656078
RADIATED 1 466066686670625574
RADIATED 2 436165666463585471
RADIATED 3 456465676564605672
CHAT/4-630 N
INLET 1 577177797781736686
INLET 2 547276777574696583
INLET 3 567576787675716784
OUTLET 1 636973758282756786
OUTLET 2 576670727874686381
OUTLET 3 636970727874686381
RADIATED 1 496369716973655878
RADIATED 2 466468696766615775
RADIATED 3 486768706867635976
CHAT/4-710 N
INLET 1 617581838185777089
INLET 2 587680817978736986
INLET 3 607980828079757187
OUTLET 1 677377798686797190
OUTLET 2 617074768278726785
OUTLET 3 677374768278726785
RADIATED 1 536773757377696281
RADIATED 2 506872737170656178
RADIATED 3 527172747271676379
CHAT/6-560 N
INLET 1 445864666468605372
INLET 2 415963646261565269
INLET 3 436263656362585471
OUTLET 1 505660626969625473
OUTLET 2 445357596561555068
OUTLET 3 505657596561555068
RADIATED 1 365056585660524564
RADIATED 2 335155565453484461
RADIATED 3 355455575554504663
CHAT/6-630 N
INLET 1 486268706872645776
INLET 2 456367686665605673
INLET 3 476667696766625875
OUTLET 1 546064667373665877
OUTLET 2 485761636965595472
OUTLET 3 546061636965595472
RADIATED 1 405460626064564968
RADIATED 2 375559605857524865
RADIATED 3 395859615958545067
CHAT/6-710 N
INLET 1 516571737175676080
INLET 2 486670716968635977
INLET 3 506970727069656178
OUTLET 1 576367697676696180
OUTLET 2 516064667268625775
OUTLET 3 576364667268625775
RADIATED 1 435763656367595272
RADIATED 2 405862636160555169
RADIATED 3 426162646261575370
CHAT/6-800 N
INLET 1 556975777579716484
INLET 2 527074757372676381
INLET 3 547374767473696582
OUTLET 1 616771738080736584
OUTLET 2 556468707672666179
OUTLET 3 616768707672666179
RADIATED 1 476167696771635676
RADIATED 2 446266676564595573
RADIATED 3 466566686665615774

Mounting Accessories

The following accessories are available for the CHAT-N series fans:

ACOPEL F400 N

Circular flexible connector, certified F400-120. Can be installed at the inlet or outlet side.

APC

Protection guards for direct connection to the inlet-outlet fan flange connector.

CTI CVA/CHAT

Outdoor cover designed for outdoor installations.

CHAT-N Model APC Model CTI CVA/CHAT Model
400 APC-400 CTI CVA-355/400 CHAT-400/450
450 APC-450 CTI CVA-355/400 CHAT-400/450
500 APC-500 CTI CVA-500 CHAT-500
560 APC-560 CTI CVA-9000 CHAT-560
630 APC-630 CTI CVA-14000 CHAT-630
710 APC-710 CTI CVA-17000 CHAT-710
800 APC-800 CTI CHAT-800 N

* For more information see Mounting accessories.

PDF preview unavailable. Download the PDF instead.

EN CHAT-N Adobe PDF Library 15.0 Adobe InDesign CC 13.1 (Macintosh)

Related Documents

Preview S&P EB-N Series Centrifugal Fans - Product Overview
Discover the S&P EB-N Series centrifugal fans, featuring an integrated back draft shutter, polypropylene construction, and high performance for demanding ventilation applications up to 40°C.
Preview S&P CTVT HP Series Centrifugal Roof Mounted Fans - Technical Specifications
Detailed technical specifications and installation guide for S&P CTVT HP Series centrifugal roof mounted fans, including F400-120 fire extraction models. Features include motor details, acoustic characteristics, and installation components.
Preview S&P TTT-N Series Axial Flow Fans | Industrial Ventilation & ATEX Certified
Explore the S&P TTT-N Series cylindrical cased axial flow fans. Features include high-temperature operation (120°C), robust construction, ATEX certified options for hazardous environments, and easy maintenance. Ideal for industrial ventilation applications.
Preview S&P EP-N Series Portable Electric Fan Heaters - Product Overview
Detailed information on the S&P EP-N Series portable electric fan heaters, designed for commercial, industrial, and drying applications. Features include IP24 rating, steel construction, quiet axial fan, adjustable settings, thermostat, and thermal protection.
Preview S&P EC-N Series Wall-Mounted Fan Heaters - Technical Specifications
Detailed technical specifications for S&P's EC-N Series wall-mounted fan heaters, including EC-9N, EC-3N, EC-5N, EC-12N, and EC-15N models. Features, technical data, and dimensions for commercial and industrial heating applications.
Preview S&P Serie COMPACT Axial Fans - Installation and User Manual
Comprehensive instructions manual for S&P Serie COMPACT axial fans, covering installation, safety, operation, maintenance, and recycling. Includes wiring diagrams for HCFB, HCFT, TCBB, and TCBT models.
Preview S&P Centrifugal In-Line Fans VENT-NK/VENT-N Series: Technical Specifications and Performance Data
Detailed technical specifications, performance curves, acoustic data, and accessory information for S&P's VENT-NK and VENT-N series centrifugal in-line duct fans.
Preview S&P CHGT Series Axial Flow Cabinet Fans - Technical Datasheet
Detailed specifications and features of S&P CHGT Series axial flow cabinet fans, designed for smoke extraction in fire conditions, with certifications like F400-120 and F300/F200-120. Includes information on construction, impellers, motors, and installation.