Vaxcel C0264 Assembly and Installation Instructions
Model Number: C0264
[warning-symbol] WARNING
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.
NOTE
- Before installing, consult local electrical codes for wiring and grounding requirements.
- READ AND SAVE THESE INSTRUCTIONS.
Hardware Package (included)
The hardware package contains the following items:
- Mounting Strap Unit (A)
- Mounting Screw (B)
- Wire Connector (C)
- Finial (D)
Diagram illustrating the assembly of the lighting fixture. It shows an outlet box, house ground wire, hex nut, washer, mounting strap unit (A), green ground screw, mounting screw (B), threaded pipe, wire connector (C), fixture wire, fixture ground wire, and the fixture itself, connected to the outlet box.
Installation Steps
Turn off the power at fuse or circuit box.
-
Attach the mounting strap unit (A) to the outlet box by using two mounting screws (B).
-
Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:
- Connect the hot wire (black insulation) from the fixture to the black wire from the power source.
- Connect the neutral wire (white insulation) from the fixture to the white wire from the power source.
- Attach the fixture ground wire (bare wire) to the mounting strap unit (A) with the green ground screw. Then, depending on local code, connect it to the house ground wire with the wire connector (C).
Carefully put all of the wires back into the outlet box.
-
Remove the finial (D) from the mounting strap unit (A).
-
Attach the fixture to the mounting strap unit (A) by inserting the finial (D).
NOTE: Depth of threaded pipe may need to be adjusted to properly fit the finial.
Illustration of the finial (D) and a note: 'Max. 60W Type B Bulb (not included)'.
-
Install 6 x 60W Max. candelabra base bulbs (not included). Check relamping label at socket area or packaging for maximum wattage allowed.
Turn on the power at fuse or circuit box.
Spare Parts List
The following parts are available for re-order if damaged or missing.
- Mounting Strap Unit (A)
- Mounting Screw (B)
- Wire Connector (C)
- Finial (D)
Assembly Kit 6480MM (1 SET)
Diagram of the ceiling fixture with dimensions. Dimension A measures 8 inches, and dimension B measures 16-1/4 inches.