TheraPure TPP220M UV Germicidal Air Purifier
Owner's Guide
Thank you for purchasing the TheraPure® 220M air purifier. This device offers UV germicidal protection to reduce germs and permanent HEPA-type filtration to purify the air, significantly improving air quality in your home, office, or other environments. It comes with a one-year limited warranty.
For more information and product upgrades, visit www.envionproducts.com.
Please read these instructions carefully for optimal performance and safety.
Safety Instructions
Read and Save These Instructions
WARNING: RISK OF ELECTRICAL SHOCK
Safety precautions should always be used when operating this or any electrical appliance. Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the warnings below.
Use only as described in this TheraPure manual. To reduce the risk of electric shock, do not attempt to service the product in any way other than in the manner described in the "Cleaning & Maintenance" section of this manual.
Read All Instructions Before Operating the Air Purifier.
- This product operates at 120V AC, 60Hz only.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
- Do not operate the product in any greasy environment, such as in the kitchen. This product is not intended to filter oil or grease from the air.
- Do not use the TheraPure® 220M air purifier in bathrooms or other humid environments. Do not use near fireplaces or in areas where flammable or combustible vapors or products may exist.
- Always unplug the power cord from the electrical outlet when the purifier is not in use, before cleaning, inserting or removing parts or before moving to another location.
- Never run the air purifier unless it is fully assembled.
- This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
- Always turn off all controls before unplugging the TheraPure® 220M air purifier from the outlet.
- Attempting to service the TheraPure® 220M air purifier in any way that is not described in this owner's manual will cause the warranty to be voided and could cause serious personal injury to the user and/or result in considerable damage to the unit.
- Do not place the cord near a heated surface.
- Do not operate this product with a damaged cord or plug. Discard the product or return to an authorized service facility for examination and/or repair.
- Never use the power cord to pick up, carry, drag, pull, or lift the TheraPure® 220M air purifier. Do not pull the cord against or around sharp corners and edges. This could result in injury to the user or damage to the cord.
- Always remove the plug from its power outlet by holding onto the plug itself and pulling gently. Never pull on the cord itself to unplug it from its power outlet.
- Use care when operating the TheraPure® 220M air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing and jewelry away from openings.
- Never touch the TheraPure® 220M air purifier or its plug when your hands are wet.
- The TheraPure® 220M air purifier is an electrical appliance. Adult supervision is required when operating the TheraPure® 220M in the presence of children.
- To reduce the risk of fire or electric shock, do not use this air purifier with any solid-state speed control devices.
Important Warnings
UV Lamp Notice
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision. Never look directly at the UV lamp while it is illuminated; doing so could cause loss of vision! Only view illumination through the window at the front of the unit. To prevent exposure to ultraviolet light, disconnect the power to the unit before servicing any part of the TheraPure® 220M air purifier.
UV Lamp Disposal
If the UV lamp breaks, turn off the unit. Do not operate the unit with a broken lamp. Do not use a vacuum to clean up breakage. Sweep debris into a plastic bag and dispose of properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp(s). To order a replacement lamp, call 1.800.875.8577 or go to www.envionproducts.com.
Mercury Notice
Because the TheraPure® 220M contains a light bulb and light bulbs contain mercury, Envion is required to provide the following warning:
WARNING: This product contains mercury, a chemical known to the State of California to cause birth defects or other reproductive harm.
Do not place your used lamp(s) in the trash. Disposal of any item containing mercury must be in accordance with any hazardous waste disposal or recycling laws and regulations of your state.
Product Benefits
Triple action purification:
- Permanent HEPA-type filter takes particles out of the air, purifying it.
- UV lamp kills germs, such as viruses and bacteria.
- Photo catalyst filter helps remove VOCs (volatile organic compounds) from the air, including toxic fumes, such as paint and new carpet fumes.
- Effectively removes smoke, pollen, dust, animal dander, dust mites, mold and bacteria.
- 3 speed fan setting – lets you select the desired cleaning level.
Main Parts
- 1. Locking Latch
- 2. Air Inlet Grill
- 3. Permanent HEPA-type filter: The permanent filter removes small visible and non-visible particles down to 0.1 microns in size.
- 4. UV Lamp Cover
- 5. Control Panel
- 6. Control Dial: Offers 3 speed settings: low, medium, and high, for you to choose from according to the air quality needs in the room.
- 7. UV Indicator Light Bar
- 8. UV/VOC Button: Activates the germicidal UV/VOC light to kill harmful airborne bacteria, germs, and viruses, and reduce harmful VOCs (volatile organic compounds).
- 9. Air Outlet Grill
- 10. Base of Unit
- 11. UV Lamp
Operating the TheraPure® 220M
Getting Ready
Before using the TheraPure® 220M air purifier, please read the following important information.
Electrical Ratings:
- Setting: 120Vac, 60 Hz
- Power consumption: 35 watts (0.5 ampere) at high fan speed, 3 watt UV light lamp
- Net weight: 5.2 lbs.
- Dimension (LxWxH): 9.6" x 7.9" x 15.1"
Replacement Parts:
- Lamp: TPP2200
- Filter: TPP220F
Locate a level surface on which to place the TheraPure® 220M air purifier near a 120V outlet. Position your TheraPure® at least one foot (12 inches) from the wall. Plug in the unit.
Safety Placement Guidelines:
- Do not place near fans.
- Keep both sides of the unit at least 1 foot away from a wall.
- Do not place the unit near curtains.
- Placing the unit close to the source of air pollution is an effective way to improve indoor air quality.
Note: DO NOT run the TheraPure® 220M with a broken filter. Replace the filter if it has a tear or a hole in it.
If the filter is damaged or needs replacement, please visit the Therapure® website at www.envionproducts.com, or call 1.800.875.8577, to order a replacement filter.
Controls/Settings
Power Control: To operate the TheraPure® 220M air purifier, turn the Control Dial clockwise to turn on.
Speed Control: The TheraPure® 220M has three different speeds of cleaning: LOW, MED, and HI. Turn the knob ONCE for LOW, TWICE for MED, and THIRD for HI.
UV Control: Press the "UV/VOC" button to turn on the UV lamp to kill harmful airborne germs and reduce harmful VOCs (volatile organic compounds). Press it again to turn off the UV and VOC. A blue UV indicator light will illuminate around the button when UV/VOC is turned on.
Cleaning & Maintenance
Cleaning the Permanent HEPA-type Filter:
Keep the TheraPure® 220M functioning properly by cleaning the permanent HEPA-type filter every four weeks. More frequent cleaning may be necessary if the unit is in an area with a high level of airborne contaminants (e.g., smoke, pet dander).
NOTE: Always ensure the TheraPure® 220M is turned off and unplugged before cleaning.
- Vacuuming will restore the performance of the permanent HEPA-type filter. The filter may appear stained, which is normal and does not affect performance.
- Do not use water or any household cleaners or detergents to clean the permanent HEPA-type filter.
- The inlet grill may be cleaned with a vacuum or a slightly damp cloth (after the unit is turned off and unplugged).
Steps for Cleaning the Permanent HEPA-type Filter:
- Release the inlet grill by pressing on the locking latch.
- Remove the inlet grill from the unit.
- Grasp the left and right frames of the permanent HEPA-type filter and remove it.
- To clean the filter, use the brush or crevice attachment with a vacuum cleaner. Run the attachment along the inlet and outlet sides of the filter, cleaning between the crevices as much as possible. Do not use water or household cleaners.
- Once cleaned and checked for damage, replace the filter in the reverse order of removal.
Exposing the TheraPure® 220M to candle/oil/fireplace soot and smoke is not recommended and will require more frequent cleaning.
Cleaning External Surfaces
- Turn off and unplug the unit.
- Use a washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces.
- Do not allow water to enter internal parts, as this could damage the unit and result in electrical shock or injury.
- Allow the unit to thoroughly dry before use.
UV Lamp
The lifetime of the UV lamp is up to 12 months of continuous, effective operation. After this time, the bulb may remain illuminated, but its effectiveness is greatly reduced. For maximum germicidal protection, replace the UV bulb annually.
If the lamp stops functioning or needs replacement, please visit www.envionproducts.com to order a replacement lamp, or call 1.800.875.8577.
Caution:
- Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the lamp.
- Never operate the unit without a filter or with a damaged filter. The UV lamp cover must be installed at all times. The UV light can cause severe damage to eyes and could cause blindness.
UV Lamp Notice Warning:
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision. Never look directly at the UV lamp while it is illuminated – doing so could cause loss of vision!
Replacing the UV Lamp
Before replacing the UV lamp, ensure the TheraPure® air purifier is turned off and unplugged. Let the lamp cool down for 5 minutes before replacing it.
Steps for Replacing the UV Lamp:
- Release the inlet grill by pressing on the locking latch.
- Remove the two bolts securing the UV lamp cover and remove the cover.
- Unscrew the old UV lamp from the lamp base.
- Install the new UV lamp into the lamp base.
- Install the UV lamp cover with the two bolts.
- Install the inlet grill.
Troubleshooting
Problem | Reason | Solution |
---|---|---|
Unit will not operate. | Power button has not been turned on. Unit is unplugged. The inlet grill has not been installed & locked into place. | Press the Power button. Check to ensure unit is plugged in. Check to make sure filter is properly installed & locked into place. |
Reduced airflow or poor filtering. | The inlet or outlet grill may be blocked. Permanent filter may be clogged. | Check to ensure nothing is blocking air inlet & air outlet. Check & clean filter, if necessary. |
No visible light in the UV light view window. | UV button is not turned on. UV lamp is broken. | Check that the UV button is turned on. Replace the UV lamp. |
One-Year Limited Warranty
Your TheraPure® 220M air purifier is warranted to be free from defects in materials and workmanship for one year from the original purchase date. Should the product have a defect, Envion will repair or replace it without charge (a shipping and processing fee may apply). To obtain service under warranty, call the customer service center toll-free at 800.875.8577.
This warranty does not cover damage caused by accident, misuse, or failure to maintain and clean the product as specified. This warranty applies only to the original purchaser.
Implied warranties of merchantability and fitness for a particular purpose are limited to the warranty period. No other warranties, express or implied, will apply after this period.
Some states do not allow limitations on the duration of implied warranties, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.
Contact Info for Warranty Service:
TheraPure® by Envion LLC
P.O. Box 9159 | Van Nuys, CA | 91409-8291
1.800.875.8577 | www.envionproducts.com
©2013 Envion, LLC. All Rights Reserved. Patents pending.
Arbitration Agreement
PLEASE READ THIS AGREEMENT CAREFULLY. You accept the terms of this Agreement by retaining the Products for more than thirty (30) days after receipt. If you do not agree, you may return the Product within thirty (30) days of receipt for a full refund.
This Arbitration Agreement contains a mandatory arbitration provision that affects your legal rights and remedies. Disputes between you and the manufacturer, distributor, and/or seller must be resolved through binding arbitration, not in court. It also prohibits class action or representative proceedings.
1. Resolution of Claims or Disputes.
Any claim or dispute arising out of or relating to the Product or this Agreement shall be resolved through final, binding arbitration. This applies regardless of whether the claim involves tort, fraud, misrepresentation, product liability, negligence, violation of a statute, or any other legal theory. You waive your right to bring a lawsuit and have it resolved by a judge or jury.
2. Limitation of Legal Remedies.
Arbitrations shall be conducted on an individual (not class-wide) basis. An arbitrator shall have no authority to award class-wide relief. This Agreement prohibits commencing arbitration proceedings as a representative of others or joining in any arbitration proceedings brought by any other person. No class or representative actions are permitted.
3. Arbitration Procedures.
- Before instituting arbitration, contact Envion to try to resolve the matter (call 800-218-3560).
- Arbitration will be conducted according to JAMS Comprehensive Arbitration Rules and Procedures.
- The arbitration will be conducted by an arbitrator with at least five years of arbitration experience.
- Arbitration will be conducted in the State of California or your location. For claims of $10,000 or less, you may choose in-person, telephone, or submission-based arbitration.
- Envion shall pay arbitration costs, including JAMS fees and arbitrator fees. Envion shall pay its own counsel, expert, and witness fees. You shall pay your own counsel, expert, and witness fees unless otherwise provided by law.
4. Choice of Law.
This Agreement and arbitration shall be governed by the Federal Arbitration Act. Otherwise, this Agreement and the rights of the parties shall be governed by and construed in accordance with the laws of the State of California, exclusive of conflict or choice of law rules.
5. Severability.
If any provision is found unlawful, unenforceable, or void, that provision will be ineffective only to that extent, and the remainder of the provision and all other provisions shall remain fully enforceable.