Choosing your UPS
1. Choose the appropriate technology
Understanding the nine types of electrical faults is key to selecting the right UPS technology:
- 1. POWER FAILURE
- 2. POWER SAG
- 3. POWER SURGE
- 4. UNDERVOLTAGE
- 5. OVERVOLTAGE
- 6. ELECTRICAL NOISE
- 7. FREQUENCY VARIATION
- 8. SWITCHING TRANSIENT
- 9. HARMONIC DISTORTION
Passive Standby (Off-Line): Offers protection for less critical equipment against the first three types of electrical faults. Typical applications include PCs and home equipment. Example UPS models: Eaton 3S, Eaton Protection Station, and Eaton Ellipse ECO.
Line Interactive: Suitable for office applications where workstations are connected via a network, providing effective protection against the five most common types of faults. Typical applications include workstation/server, network and data storage equipment, and point-of-sale terminals. Example UPS models: Eaton Ellipse PRO, Eaton 5P, and Eaton 5PX.
Double Conversion (On-Line): Provides optimal protection against all nine types of electrical faults and offers a wide range of connectivity options. Ideal for critical servers and any equipment sensitive to electrical faults. Example UPS model: Eaton 9PX.
2. Calculate the power consumption of the equipment in question
The power consumption is usually indicated on the equipment's label in watts (W) or volt-amperes (VA). If consumption is given in amperes (A), convert it to VA by multiplying by 230V (for single phase). If consumption is in watts (W), convert it to VA by dividing by 0.7. It is recommended to add a margin of 20-30% for future changes.
Examples of electrical loads and average power in VA:
- Hub/Switch/Modem: ~50 VA
- Inkjet printer: ~100 VA
- PC/Mac: ~150 VA
- PC + 19" flat-screen monitor: ~250 VA
- PC + 22" flat-screen monitor: ~350 VA
- Server/Laser printer: > 400 VA
3. Determine how much backup battery runtime (autonomy) is required
A UPS battery typically provides 10 to 30 minutes of autonomy for standard use, sufficient to back up and shut down most computer systems during a power failure. For applications requiring longer backup times (e.g., telephone systems, critical servers, remote sites, industrial or medical facilities), verify if the UPS supports additional external battery modules to extend autonomy.
4. Choose the right UPS
Follow these steps:
- Choose the level of power protection (Technology).
- Choose the load to protect (Load).
- Identify the suitable products based on your needs.
UPS Product Overview by Technology and Load:
Technology | Product | Load |
---|---|---|
Passive Standby | Eaton 3S | 550 - 700VA |
Passive Standby | Eaton protection station | 500 - 800VA |
Passive Standby | Eaton ellipse ECO | 500 - 1600VA |
Line Interactive | Eaton ellipse PRO | 650 - 1600VA |
Line Interactive | Eaton 5P | 650 - 1550VA |
Line Interactive | Eaton 5PX | 1500 - 3000VA |
Double Conversion | Eaton 9PX | 1000 - 11000VA |
Detailed UPS Product Specifications
The following tables provide detailed specifications for Eaton UPS systems.
Passive Standby (Off-Line) UPS
TECHNOLOGY | UPS PRODUCT NAME | SALES REFERENCE | STANDARD WARRANTY | WARRANTY + 1 (Extended 1-year warranty) | WARRANTY + 3 (Extended 3-years warranty) | POWER IN VA/W | |
---|---|---|---|---|---|---|---|
PASSIVE STANDBY (Off-Line) | Eaton 3S | 3S550DIN | 2 years | W1001WEB | W3001WEB | 550VA/330W | |
PASSIVE STANDBY (Off-Line) | Eaton 3S | 3S700DIN | 2 years | W1001WEB | W3001WEB | 700 VA/420W | |
PASSIVE STANDBY (Off-Line) | Eaton protection station | Protection Station 500 | 66943 | 2 years | W1001WEB | W3001WEB | 500VA/250W |
PASSIVE STANDBY (Off-Line) | Eaton protection station | Protection Station 650 USB | 61062 | 2 years | W1001WEB | W3001WEB | 650VA/400W |
PASSIVE STANDBY (Off-Line) | Eaton protection station | Protection Station 800 USB | 61082 | 2 years | W1001WEB | W3001WEB | 800VA/500W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 500 DIN | EL500DIN | 2 years | W1001WEB | W3001WEB | 500VA/300W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 650 DIN | EL650DIN | 2 years | W1001WEB | W3001WEB | 650VA/400W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 650 USB DIN | EL650USBDIN | 2 years | W1001WEB | W3001WEB | 650VA/400W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 800 USB DIN | EL800USBDIN | 2 years | W1001WEB | W3001WEB | 800VA/500W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 1200 USB DIN | EL1200USBDIN | 2 years | W1002WEB | W3002WEB | 1200VA/750W |
PASSIVE STANDBY (Off-Line) | Eaton ellipse eco | Ellipse ECO 1600 USB DIN | EL1600USBDIN | 2 years | W1002WEB | W3002WEB | 1600VA/1000W |
Line Interactive UPS
TECHNOLOGY | UPS PRODUCT NAME | SALES REFERENCE | STANDARD WARRANTY | WARRANTY + 1 (Extended 1-year warranty) | WARRANTY + 3 (Extended 3-years warranty) | POWER IN VA/W | |
---|---|---|---|---|---|---|---|
LINE INTERACTIVE | Eaton Ellipse Pro | Ellipse PRO 650 DIN | ELP650DIN | 3 years | W1002WEB | W3002WEB | 650VA/400W |
LINE INTERACTIVE | Eaton Ellipse Pro | Ellipse PRO 850 DIN | ELP850DIN | 3 years | W1002WEB | W3002WEB | 850VA/510W |
LINE INTERACTIVE | Eaton Ellipse Pro | Ellipse PRO 1200 DIN | ELP1200DIN | 3 years | W1002WEB | W3002WEB | 1200VA/750W |
LINE INTERACTIVE | Eaton Ellipse Pro | Ellipse PRO 1600 DIN | ELP1600DIN | 3 years | W1003WEB | W3003WEB | 1600VA/1000W |
LINE INTERACTIVE | Eaton 5P (Tower) | 5P 650 | 5P650I* | 3 years | W1002WEB | W3002WEB | 650VA/420W |
LINE INTERACTIVE | Eaton 5P (Tower) | 5P 850 | 5P850I* | 3 years | W1003WEB | W3003WEB | 850VA/600W |
LINE INTERACTIVE | Eaton 5P (Tower) | 5P 1150 | 5P1150I* | 3 years | W1003WEB | W3003WEB | 1150VA/770W |
LINE INTERACTIVE | Eaton 5P (Tower) | 5P 1550 | 5P1550I* | 3 years | W1004WEB | W3004WEB | 1550VA/1100W |
LINE INTERACTIVE | Eaton 5P (Rack 1U) | 5P 650 Rack 1U | 5P650IR* | 3 years | W1003WEB | W3003WEB | 650VA/420W |
LINE INTERACTIVE | Eaton 5P (Rack 1U) | 5P 850 Rack 1U | 5P850IR* | 3 years | W1003WEB | W3003WEB | 850VA/600W |
LINE INTERACTIVE | Eaton 5P (Rack 1U) | 5P 1150 Rack 1U | 5P1150IR* | 3 years | W1004WEB | W3004WEB | 1150VA/770W |
LINE INTERACTIVE | Eaton 5P (Rack 1U) | 5P 1550 Rack 1U | 5P1550IR* | 3 years | W1004WEB | W3004WEB | 1550VA/1100W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 1500 RT 2U | 5PX1500IRT* | 3 years | W1004WEB | W3004WEB | 1500VA/1350W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 1500 RT 2U Netpack (2) | 5PX1500IRTN* | 3 years | W1004WEB | W3004WEB | 1500VA/1350W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 2200 RT 2U | 5PX2200IRT* | 3 years | W1004WEB | W3004WEB | 2200VA/1980W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 2200 RT 2U Netpack (2) | 5PX2200IRTN* | 3 years | W1005WEB | W3005WEB | 2200VA/1980W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 3000 RT 3U | 5PX3000IRT3U* | 3 years | W1005WEB | W3005WEB | 3000VA/2700W |
LINE INTERACTIVE | Eaton 5PX (Rack/Tower) | 5PX 3000 RT 2U Netpack (2) | 5PX3000IRTN* | 3 years | W1005WEB | W3005WEB | 3000VA/2700W |
Double Conversion (On-Line) UPS
TECHNOLOGY | UPS PRODUCT NAME | SALES REFERENCE | STANDARD WARRANTY | WARRANTY + 1 (Extended 1-year warranty) | WARRANTY + 3 (Extended 3-years warranty) | POWER IN VA/W | |
---|---|---|---|---|---|---|---|
DOUBLE CONVERSION (On-Line) | Eaton 9SX (1-PHASE) | 9SX 700 | 9SX700I | 2 years | W1003WEB | W3003WEB | 700VA/630W |
DOUBLE CONVERSION (On-Line) | Eaton 9SX (1-PHASE) | 9SX 1000 | 9SX1000I | 2 years | W1004WEB | W3004WEB | 1000VA/900W |
DOUBLE CONVERSION (On-Line) | Eaton 9SX (1-PHASE) | 9SX 1500 | 9SX1500I | 2 years | W1004WEB | W3004WEB | 1500VA/1350W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 1000 RT2U | 9PX1000IRT2U | 3 years* | W1004WEB | W3004WEB | 1000VA/1000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 1000 RT2U Netpack (2) | 9PX1000IRTN | 3 years* | W1004WEB | W3004WEB | 1000VA/1000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 1500 RT2U | 9PX1500IRT2U | 3 years* | W1005WEB | W3005WEB | 1500VA/1500W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 1500 RT2U Netpack (2) | 9PX1500IRTN | 3 years* | W1005WEB | W3005WEB | 1500VA/1500W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT2U | 9PX2200IRT2U | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT2U Netpack (2) | 9PX2200IRTN | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT3U | 9PX2200IRT3U | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT3U Hotswap (4) HW (3) | 9PX2200IRTBPH | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT3U Hotswap (4) IEC | 9PX2200IRTBP | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 2200 RT3U Hotswap (4) DIN | 9PX2200IRTBPD | 3 years* | W1005WEB | W3005WEB | 2200VA/2200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT2U | 9PX3000IRT2U | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT2U Netpack (2) | 9PX3000IRTN | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT3U | 9PX3000IRT3U | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT3U Hotswap (4) HW (3) | 9PX3000IRTBPH | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT3U Hotswap (4) IEC | 9PX3000IRTBP | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (1-3kva) (Rack/Tower) | 9PX 3000 RT3U Hotswap (4) DIN | 9PX3000IRTBPD | 3 years* | W1006WEB | W3006WEB | 3000VA/3000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 5kVA 1:1 HotSwap (4) | 9PX5KIBP | 2 years | W1007WEB | W3007WEB | 5000VA/4500W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 5kVA 1:1 RT3U Netpack (2) | 9PX5KIRTN | 2 years | W1007WEB | W3007WEB | 5000VA/4500W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 6kVA 1:1 HotSwap (4) | 9PX6KIBP | 2 years | W1007WEB | W3007WEB | 6000VA/5400W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 6kVA 1:1 RT3U Netpack (2) | 9PX6KIRTN | 2 years | W1007WEB | W3007WEB | 6000VA/5400W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 8kVA 1:1 HotSwap (4) | 9PX8KIBP | 2 years | W1008WEB | W3008WEB | 8000VA/7200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 8kVA 1:1 RT6U HotSwap (4) Netpack(2) | 9PX8KIRTNBP | 2 years | W1008WEB | W3008WEB | 8000VA/7200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 11kVA 1:1 HotSwap (4) | 9PX11KIBP | 2 years | W1008WEB | W3008WEB | 11000VA/10000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (1-phase) | 9PX 11kVA 1:1 RT6U HotSwap (4) Netpack (2) | 9PX11KIRTNBP | 2 years | W1008WEB | W3008WEB | 11000VA/10000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 6kVA 3:1 HotSwap (4) | 9PX6KIBP31 | 2 years | W1008WEB | W3008WEB | 6000VA/5400W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 6kVA 3:1 RT3U HotSwap (4) Netpack (2) | 9PX6KIRTNBP31 | 2 years | W1008WEB | W3008WEB | 6000VA/5400W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 8kVA 3:1 HotSwap (4) | 9PX8KIBP31 | 2 years | W1008WEB | W3008WEB | 8000VA/7200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 8kVA 3:1 RT6U HotSwap(4) Netpack (2) | 9PX8KIRTNBP31 | 2 years | W1008WEB | W3008WEB | 8000VA/7200W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 11kVA 3:1 HotSwap (4) | 9PX11KIBP31 | 2 years | W1008WEB | W3008WEB | 11000VA/10000W |
DOUBLE CONVERSION (On-Line) | Eaton 9PX (5-11kva) (3-PHASE/1-PHASE) | 9PX 11kVA 3:1 RT6U HotSwap (4) Netpack (2) | 9PX11KIRTNBP31 | 2 years | W1008WEB | W3008WEB | 11000VA/10000W |
Notes: (1) Controllable in 2 groups. (2) Included: rack kit + SNMP/Web card (NETWORK-M2). (3) HW = terminal block. (4) Hotswap: manual maintenance bypass. *2-year battery applies to some models.
UPS Communications, Outlets, Dimensions, and Accessories
COMMUNICATIONS | TEL/INTERNET PROTECTION | OUTLETS | DIMENSIONS IN MM (height x width x depth/weight in kg) | ACCESSOIRES |
---|---|---|---|---|
USB | Tel/Internet DIN 6 (3+3) | 86 x 140 x 335 / 2.9 | ||
USB | Tel/Internet DIN 6 (3+3) | 86 x 170 x 335 / 3.8 | IEC models available (3S550IEC and 3S700IEC) with 8 IEC 10A (4+4) outlets. USB cable included (USB models). | |
/ | Tel/Internet DIN 6 (3+3) | 155 x 304 x 137 / 2.9 | ||
USB | Tel/Internet DIN 8 (4+4) | 185 x 327 x 149 / 3.8 | 2U rack-mount kit (ELRACK) | |
USB | Tel/Internet DIN 8 (4+4) | 185 x 327 x 149 / 4 | Wall-mount kit (ELWALL). Note 1: USB cable included (USB). | |
USB | Tel/Internet DIN 4 (3+1) | 263 x 81 x 235 / 2.9 | ||
USB | Tel/Internet DIN 4 (3+1) | 263 x 81 x 235 / 3.6 | 2U rack-mount kit (ELRACK) | |
USB | Tel/Internet DIN 4 (3+1) | 263 x 81 x 235 / 3.6 | Wall-mount kit (ELWALL). | |
USB | Tel/Internet DIN 4 (3+1) | 263 x 81 x 235 / 4.1 | Note 1: USB cable included. | |
USB | Tel/Internet DIN 8 (4+4) | 305 x 81 x 312 / 6.7 | ||
USB | Tel/Internet DIN 8 (4+4) | 305 x 81 x 312 / 7.8 | Note 1: USB cable included. | |
USB | Tel/Internet DIN 4 (3+1) | 260 x 82 x 285 / 6.6 | 2U rack-mount kit (ELRACK) | |
USB | Tel/Internet DIN 4 (3+1) | 260 x 82 x 285 / 7.3 | Wall-mount kit (ELWALL). | |
USB | Tel/Internet DIN 8 (4+4) | 275 x 82 x 390 / 9.9 | ||
USB | Tel/Internet DIN 8 (4+4) | 275 x 82 x 390 / 11.3 | Note 1: USB cable included. | |
USB/RS232/Contacts + 1 slot | 4 IEC 10A incl. 2 that are controllable (1) | 230 x 150 x 345 / 7.8 | Network card (SNMP/Web) (NETWORK-M2) | |
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 230 x 150 x 345 / 10.4 | Dry contact card (RELAY-MS) | |
USB/RS232/Contacts + 1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 230 x 150 x 345 / 11.1 | Manual bypass Hotswap (4) MBP (DIN : MBP3KID, IEC: MBP3KI, terminal block: MBP3KIH) | |
USB/RS232/Contacts + 1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 230 x 150 x 445 / 15.6 | 10A cable kit for Hotswap (4) (CBLMBP10EU) | |
USB/RS232/Contacts + 1 slot | 4 IEC 10A incl. 2 that are controllable (1) | 43.2 x 438 x 364 / 8.6 | FlexPDU (DIN: EFLX8D, IEC: EFLX12I) | |
USB/RS232/Contacts + 1 slot | 4 IEC 10A incl. 2 that are controllable (1) | 43.2 x 438 x 509 / 13.8 | ||
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 43.2 x 438 x 509 / 14.6 | ||
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 43.2 x 438 x 554 / 19.4 | External battery modules: (EBM) | |
USB/RS232/Contacts + 1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 86.2 x 441 x 522 / 27.6 | Network card (SNMP/Web) (NETWORK-M2) | |
USB/RS232/Contacts/SNMP included | 8 IEC 10A incl. 4 that are controllable (1) | 86.2 x 441 x 522 / 27.6 | Dry contact card (RELAY-MS) | |
USB/RS232/Contacts + 1 slot | 8 IEC 10A incl. 4 that are controllable (1) + 1 IEC 16A | 86.2 x 441 x 522 / 28.5 | Modbus & SNMP card (MODBUS-MS) | |
USB/RS232/Contacts/SNMP included | 8 IEC 10A incl. 4 that are controllable (1) + 1 IEC 16A | 86.2 x 441 x 522 / 28.5 | Manual bypass Hotswap (4) MBP (DIN : MBP3KID, IEC: MBP3KI, TERMINAL BLOCK: MBP3KIH) | |
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 130.7 x 441 x 497 / 37.4 | 10A cable kit for Hotswap (4) (CBLMBP10EU) | |
USB/RS232/Contacts/SNMP included | 8 IEC 10A incl. 4 that are controllable (1) | 86.2 x 441 x 647 / 38.1 | FlexPDU (DIN: EFLX8D, IEC: EFLX12I) | |
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 252 x 160 x 357 / 11.5 | External battery modules: (EBM), 2m battery connection cable (EBMCBL48 AND EBMCBL72) for the 9PX model (1-3kW) | |
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 252 x 160 x 387 / 14.8 | ||
USB/RS232/Contacts + 1 slot | 6 IEC 10A incl. 3 that are controllable (1) | 252 x 160 x 437 / 18.5 | ||
USB/RS232/Contacts/+1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 450 / 17.4 | ||
USB/RS232/Contacts/+SNMP included | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 450 / 17.4 | ||
USB/RS232/Contacts/+1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 450 / 18.9 | ||
USB/RS232/Contacts/+SNMP included | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 450 / 18.9 | ||
USB/RS232/Contacts/+1 slot | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 605 / 25 | ||
USB/RS232/Contacts/+SNMP included | 8 IEC 10A incl. 4 that are controllable (1) | 86.5 x 440 x 605 / 25 | ||
USB/RS232/Contacts/+1 slot | 8 IEC 10A incl. 4 that are controllable (1) + 2 IEC 16A | 130 x 440 x 485 / 24.5 | Network card (SNMP/Web) (NETWORK-M2) (included in the Netpack version) | |
USB/RS232/Contacts/+1 slot | Terminal block + 2x4 IEC 10A controllable outlets (1) + 2 IEC 16A | 440 x 130 x 685 / 48 | Dry contact card (RELAY-MS) | |
USB/RS232/Contacts/+1 slot | Terminal block + 3 IEC 10A + 2 IEC 16A | 440 x 130 x 685 / 48 | Modbus & SNMP card (MODBUS-MS) | |
USB/RS232/Contacts/+1 slot | Terminal block + 2x4 IEC 10A controllable outlets (1) + 2 IEC 16A | 440 x 130 x 685 / 48 | Manual bypass Hotswap (4) MBP (DIN : MBP3KID, IEC: MBP3KI, TERMINAL BLOCK: MBP3KIH) | |
USB/RS232/Contacts/+SNMP included | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 84 | 10A cable kit for Hotswap (4) models 1,000 & 1,500VA (CBLMBP10EU) | |
USB/RS232/Contacts/+1 slot | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 84 | FlexPDU (DIN: EFLX8D, IEC: EFLX12I) | |
USB/RS232/Contacts/+SNMP included | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 88 | External battery modules: (EBM), 1.8m battery connection cable (EBMCBL180 AND EBMCBL240) | |
USB/RS232/Contacts/+1 slot | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 88 | HotSwap MBP Maintenance Bypass: | |
USB/RS232/Contacts/+SNMP included | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 88 | Rack kit (9RK) | |
USB/RS232/Contacts/+1 slot | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 88 | Battery integration system (BINTSYS) | |
USB/RS232/Contacts/+SNMP included | Terminal block + 4 IEC 16A | 440 x 260 x 700 / 88 | Supercharger with rack kit (SC240RT) for the 6kVA 3-phase/1-phase model and the 8 & 11kVA 1-phase/1-phase and 3-phase/1-phase models |
Select your ATS
Product | Reference | Format | Current | Inputs | Outputs | Dimensions (H x W x D, in mm) |
---|---|---|---|---|---|---|
ATS 16A | ATS16 | 1U | 16A | 2 IEC C20 + 2 input cables | 8 IEC C13 + 1 IEC C19 | 43 x 430 x 250 mm |
ATS 16A Netpack (network card included) | ATS16N | 1U | 16A | 2 IEC C20 + 2 input cables | 9 IEC C13 + 1 IEC C19 | 43 x 430 x 250 mm |
ATS 30A Netpack (network card included) | ATS30N | 1U | 30A* | Terminal block | Terminal block | 43 x 440 x 390 |
*30A up to 35°C, 25.6A up to 40°C.
Upgrade your system with PDUs from Eaton
Technology | Reference | Format | Rated current | Inputs | Outputs | Dimensions (H x W x D, in mm) | Warranty +1 (Extended 1-year warranty) | Warranty +3 (Extended 3-years warranty) |
---|---|---|---|---|---|---|---|---|
Managed (MA) | EMAB03 | 0U | 10A | C14 | 16 x C13 | 1154 x 52 x 53 | W1004WEB | W3004WEB |
Managed (MA) | EMAB04 | 0U | 16A | IEC60309 16A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Managed (MA) | EMAH28 | 1U | 16A | C20 | 8 x C13 | 1U x 19" x 203 | W1004WEB | W3004WEB |
Managed (MA) | EMAB22 | 0U | 16A | C20 | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB04 | 0U | 16A | IEC60309 16A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAH06 | 2U | 32A | IEC60309 32A (1P+N+T) | 12 x C13: 4 x C19 | 2U x 19" x 225 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB71 | 0U | 32A | IEC60309 32A (1P+N+T) | 28 x C13: 4 x C19 | 1829 x 52 x 53 | W1005WEB | W3005WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB05 | 0U | 32A | IEC60309 32A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB20 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 21 x C13: 3 x C19 | 1604 x 52 x 53 | W1005WEB | W3005WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB33 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 18 x C13: 6 x C19 | 1829 x 52 x 65 | W1005WEB | W3005WEB |
Electrical & energy monitoring of each outlet, as well as individual outlet switching. | EMAB12 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 12 x C13: 12 x C19 | 1829 x 52 x 65 | W1006WEB | W3006WEB |
Switched (SW) | ESWB03 | 0U | 10A | C14 | 16 x C13 | 1154 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU, as well as individual outlet switching. | ESWH28 | 1U | 16A | C20 | 8 x C13 | 1U x 19" x 203 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU, as well as individual outlet switching. | ESWB22 | 0U | 16A | C20 | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU, as well as individual outlet switching. | ESWB04 | 0U | 16A | IEC60309 16A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU, as well as individual outlet switching. | ESWB05 | 0U | 32A | IEC60309 32A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU, as well as individual outlet switching. | ESWB20 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 21 x C13: 3 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Metered Outlet (MO) | EMOB20 | 0U | 16A | IEC60309 16A (3P+N+T) | 21 x C13: 3 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet. | EMOB22 | 0U | 16A | C20 | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Electrical & energy monitoring of each outlet. | EMOB05 | 0U | 32A | IEC60309 32A (1P+N+T) | 20 x C13: 4 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Metered Input (MI) | EMIB00 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 36 x C13: 6 X C19 | 1829 x 52 x 53 | W1004WEB | W3004WEB |
EMIH06 | 2U | 32A | IEC60309 32A (1P+N+T) | 12 x C13: 4 x C19 | 2U x 19" x 127 | W1003WEB | W3003WEB | |
EMIH02 | 1U | 10A | C14 | 8 x C13 | 1U x 19" x 203 | W1003WEB | W3003WEB | |
EMIB03 | 0U | 10A | C14 | 16 x C13 | 1070 x 52 x 53 | W1003WEB | W3003WEB | |
EMIH28 | 1U | 16A | C20 | 8 x C13 | 1U x 19" x 203 | W1003WEB | W3003WEB | |
EMIB22 | 0U | 16A | C20 | 20 x C13: 4 x C19 | 1070 x 52 x 53 | W1003WEB | W3003WEB | |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB04 | 0U | 16A | IEC60309 16A (1P+N+T) | 20 x C13: 4 x C19 | 1070 x 52 x 53 | W1003WEB | W3003WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB06 | 0U | 32A | IEC60309 32A (1P+N+T) | 12 x C13: 4 x C19 | 1070 x 52 x 53 | W1003WEB | W3003WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB05 | 0U | 32A | IEC60309 32A (1P+N+T) | 20 x C13: 4 x C19 | 1154 x 52 x 53 | W1003WEB | W3003WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB08 | 0U | 32A | IEC60309 32A (1P+N+T) | 36 x C13: 6 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB20 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 21 x C13: 3 x C19 | 1070 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB07 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 6 x C13: 12 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB12 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 12 x C13: 12 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB32 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 24 x C13: 6 x C19 | 1604 x 52 x 53 | W1004WEB | W3004WEB |
Overall electrical & energy monitoring of the PDU and the outlet groups. | EMIB34 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 30 x C13: 12 x C19 | 1829 x 52 x 65 | W1005WEB | W3005WEB |
Basic (BA) | EBAB02 | 0U | 10A | C14 | 8 x C13 | 443 x 19" x 53 | W1001WEB | W3001WEB |
Basic (BA) | EBAB19 | 0U | 10A | C14 | 12 x C13 | 443 x 19" x 53 | W1002WEB | W3002WEB |
EBAB03 | 0U | 10A | C14 | 16 x C13 | 704 x 52 x 53 | W1002WEB | W3002WEB | |
Efficient Basic PDUs with integrated grip plug retention. | EBAB21 | 0U | 16A | C20 | 16 x C13 | 704 x 52 x 53 | W1002WEB | W3002WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB22 | 0U | 16A | C20 | 20 x C13: 4 x C19 | 1070 x 52 x 53 | W1002WEB | W3002WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB04 | 0U | 16A | IEC60309 16A (1P+N+T) | 20 x C13: 4 x C19 | 1070 x 52 x 53 | W1002WEB | W3002WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB05 | 0U | 32A | IEC60309 32A (1P+N+T) | 20 x C13: 4 x C19 | 1070 x 52 x 53 | W1002WEB | W3002WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB08 | 0U | 32A | IEC60309 32A (1P+N+T) | 36 x C13: 6 x C19 | 1604 x 52 x 53 | W1003WEB | W3003WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB20 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 21 x C13: 3 x C19 | 1070 x 52 x 53 | W1003WEB | W3003WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB00 | 0U | 16A/3Ph | IEC60309 16A (3P+N+T) | 36 x C13: 6 x C19 | 1604 x 52 x 53 | W1003WEB | W3003WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB01 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 3 x C13: 6 x C19 | 704 x 52 x 53 | W1004WEB | W3004WEB |
Efficient Basic PDUs with integrated grip plug retention. | EBAB32 | 0U | 32A/3Ph | IEC60309 32A (3P+N+T) | 24 x C13: 6 x C19 | 1154 x 52 x 53 | W1004WEB | W3004WEB |
For more information about Eaton's 3G PDUs, please visit www.eaton.com/ePDU. You couldn't find the required system in our standard list? Contact Eaton.
*All Eaton PDUs have a standard 2-year warranty.