Eaton Single-Phase UPS Selection Guide
This guide provides an overview of Eaton's single-phase UPS solutions, designed to protect various applications from power disturbances.
Understanding Power Problems
Electrical power issues can significantly impact electronic equipment. Eaton UPS systems address common problems such as:
- Power Failure: Complete loss of power from the grid due to lightning, fallen power lines, grid overload, accidents, or natural disasters.
- Voltage Sag: A short-term decrease in voltage, often caused by connecting large appliances, grid switching, atmospheric discharge, or insufficient power supply capacity. This can lead to equipment shutdown or hardware malfunction.
- Voltage Spike: A short-term increase in voltage above 110% of the nominal value, often caused by lightning strikes. Spikes can result in data loss or hardware damage.
- Undervoltage: A sustained voltage reduction (over 20%) lasting from minutes to days, sometimes implemented to manage peak demand or protect other large appliances.
- Overvoltage: A sustained voltage increase lasting from minutes to days, often caused by rapid load shedding or grid switching. This can damage hardware.
- সরবরাহে হস্তক্ষেপ (Supply Interference): High-frequency noise caused by electromagnetic interference (RFI/EMI) from sources like transmitters, welding equipment, thyristor-controlled printers, or atmospheric conditions.
- Frequency Variation: Changes in frequency stability due to generator load variations or nearby generator activity. This can cause malfunctions, data loss, system crashes, and equipment damage.
- Switching Transient: Instantaneous voltage dips (glitches) typically lasting nanoseconds.
- Harmonic Distortion: Distortion of the normal voltage waveform, usually caused by non-linear loads like switching power supplies, variable frequency drives, copiers, and fax machines. This can lead to communication errors, overheating, and hardware failures.
Eaton UPS Series Overview
Eaton offers a range of UPS series tailored for different applications:
- Off-line UPS: Suitable for PCs and multimedia devices (450 – 1600 VA).
- Line-interactive UPS: Ideal for servers, data networks, and critical applications (500 – 3000 VA).
- On-line UPS: Designed for critical applications, buildings, data centers, industry, and healthcare (700 – 11000 VA).
Product Specifications Table
The following table details various Eaton UPS models, their specifications, and features:
Product Series | Model | Order Number | Apparent Power (VA) | Real Power (W) | Backup Time (min) 50%/75%/100% Load | Battery | Outlets | Communication Interface | Dimensions (mm) (W x H x D) | Weight (kg) | Warranty (Elec./Bat.) | Warranty+1 | Warranty+3 | EBM |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Eaton 3S tower | 3S 450 FR | 3S450F | 450 | 270 | 6.5 / 3.5 / 2 | 1 x 12 V / 4.5 Ah | 6 x FR (3+3) | - | 140 x 86 x 325 | 2.9 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 3S tower | 3S 550 FR | 3S550F | 550 | 330 | 6.5 / 3.5 / 1.5 | 1 x 12 V / 5 Ah | 6 x FR (3+3) | USB | 140 x 86 x 325 | 3.2 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 3S tower | 3S 700 FR | 3S700F | 700 | 420 | 8 / 4 / 2 | 1 x 12 V / 7 Ah | 8 x FR (4+4) | USB | 170 x 86 x 335 | 4.0 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 3S tower | 3S 850 FR | 3S850F | 850 | 510 | 7.5 / 3.5 / 1.5 | 1 x 12 V / 9 Ah | 8 x FR (4+4) | USB | 170 x 86 x 335 | 4.3 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse 550 FR | 3P550F | 550 | 330 | 7.2 / 3.4 / 1.5 | 1 x 12 V / 4.5 Ah | 4 x FR (3+1) | - | 81 x 263 x 235 | 3.0 | 3/2 | W1001WEB | W3001WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse 700 FR | 3P700F | 700 | 420 | 8.3 / 4.5 / 1.5 | 1 x 12 V / 7 Ah | 4 x FR (3+1) | - | 81 x 263 x 235 | 3.7 | 3/2 | W1001WEB | W3001WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse USB 700 FR | 3P700UF | 700 | 420 | 8.3 / 4.5 / 1.5 | 1 x 12 V / 7 Ah | 4 x FR (3+1) | USB/PS slot | 81 x 263 x 235 | 3.9 | 3/2 | W1001WEB | W3001WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse USB 900 FR | 3P900UF | 900 | 540 | 10.4 / 4.3 / 1.5 | 1 x 12 V / 9 Ah | 4 x FR (3+1) | USB/PS slot | 81 x 263 x 235 | 4.4 | 3/2 | W1002WEB | W3002WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse USB 1300 FR | 3P1300UF | 1300 | 840 | 8.4 / 3.1 / 1.3 | 2 x 12 V / 7 Ah | 8 x FR (4+4) | USB/PS slot | 81 x 305 x 312 | 7 | 3/2 | W1002WEB | W3002WEB | - |
Eaton 3P Ellipse tower | 3P Ellipse USB 1700 FR | 3P1700UF | 1700 | 1040 | 9.7 / 4.2 / 1.3 | 2 x 12 V / 9 Ah | 8 x FR (4+4) | USB/PS slot | 81 x 305 x 312 | 7.8 | 3/2 | W1003WEB | W3003WEB | - |
Eaton 5E Gen2 tower | 5E 550I | 5E550I | 550 | 300 | 3 / 1 / 0 | 1 x 12 V / 4.5 Ah | 4 x IEC/10A | - | 100 x 148 x 288 | 3.8 | 2/2 | W1001WEB | - | - |
Eaton 5E Gen2 tower | 5E 700UF | 5E700UF | 700 | 360 | 5 / 1 / 0 | 1 x 12 V / 7 Ah | 2 x FR | USB | 100 x 148 x 288 | 4.4 | 2/2 | W1001WEB | - | - |
Eaton 5E Gen2 tower | 5E 900UF | 5E900UF | 900 | 480 | 5 / 0.5 / 0 | 1 x 12 V / 9 Ah | 2 x FR | USB | 100 x 148 x 288 | 5.3 | 2/2 | W1001WEB | - | - |
Eaton 5E Gen2 tower | 5E 1200UF | 5E1200UF | 1200 | 660 | 5 / 2.5 / 0.1 | 2 x 12 V / 7 Ah | 4 x FR | USB | 133 x 180 x 330 | 8.5 | 2/2 | W1002WEB | - | - |
Eaton 5E Gen2 tower | 5E 1600UF | 5E1600UF | 1600 | 900 | 5 / 2 / 0.1 | 2 x 12 V / 7 Ah | 4 x FR | USB | 133 x 180 x 330 | 9.3 | 2/2 | W1002WEB | - | - |
Eaton 5E Gen2 tower | 5E 2200UI | 5E2200UI | 2200 | 1200 | 5 / 1.5 / 0.1 | 2 x 12 V / 9 Ah | 6 x IEC/10A | USB | 133 x 180 x 330 | 9.8 | 2/2 | W1003WEB | - | - |
Eaton 5S tower | 5S 550i | 5S550I | 550 | 330 | 9.5 / 5 / 1.5 | 1 x 12 V / 5 Ah | 4 x IEC/10A (3+1) | USB | 87 x 250 x 260 | 5.0 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 5S tower | 5S 700i | 5S700I | 700 | 420 | 8.5 / 4 / 2.5 | 1 x 12 V / 7 Ah | 6 x IEC/10A (3+3) | USB | 87 x 250 x 260 | 6.0 | 2/2 | W1001WEB | W3001WEB | - |
Eaton 5S tower | 5S 1000i | 5S1000I | 1000 | 600 | 14 / 7 / 2.5 | 2 x 12 V / 7 Ah | 8 x IEC/10A (4+4) | USB | 87 x 250 x 382 | 9.5 | 2/2 | W1002WEB | W3002WEB | - |
Eaton 5S tower | 5S 1500i | 5S1500I | 1500 | 900 | 11 / 6.5 / 2 | 2 x 12 V / 9 Ah | 8 x IEC/10A (4+4) | USB | 87 x 250 x 382 | 11.1 | 2/2 | W1002WEB | W3002WEB | - |
Eaton 5SC tower | 5SC 500i | 5SC500I | 500 | 350 | 13 / 8 / 5 | 1 x 12 V / 9 Ah | 4 x IEC/10A | USB/RS-232 | 150 x 210 x 240 | 6.6 | 2/2 | W1002WEB | W3002WEB | - |
Eaton 5SC tower | 5SC 750i | 5SC750I | 750 | 525 | 12.5 / 8 / 5 | 2 x 12 V / 7 Ah | 6 x IEC/10A | USB/RS-232 | 150 x 210 x 340 | 10.4 | 2/2 | W1002WEB | W3002WEB | - |
Eaton 5SC tower | 5SC 1000i | 5SC1000I | 1000 | 700 | 13 / 8 / 5 | 2 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232 | 150 x 210 x 340 | 11.1 | 2/2 | W1003WEB | W3003WEB | - |
Eaton 5SC tower | 5SC 1500i | 5SC1500I | 1500 | 1050 | 13 / 8 / 5 | 3 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232 | 150 x 210 x 410 | 15.2 | 2/2 | W1003WEB | W3003WEB | - |
Eaton 5SC rack | 5SC 1000i | 5SC1000IR | 1000 | 700 | 11.5 / 6.9 / 4.5 | 2 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 440 x 86 x 405 | 15.0 | 2/2 | W1003WEB | W3003WEB | - |
Eaton 5SC rack | 5SC 1500i | 5SC1500IR | 1500 | 1050 | 13 / 7.4 / 4.5 | 3 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 440 x 86 x 405 | 17.8 | 2/2 | W1004WEB | W3004WEB | - |
Eaton 5SC rack/tower | 5SC 2200i | 5SC2200IRT | 2200 | 1980 | 7 / 3.6 / 2 | 4 x 12 V / 9 Ah | 8 x IEC/10A+ 1 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 441 x 86 x 522 | 26.5 | 2/2 | W1004WEB | W3004WEB | - |
Eaton 5SC rack/tower | 5SC 3000i | 5SC3000IRT | 3000 | 2700 | 10 / 5 / 2.5 | 6 x 12 V / 9 Ah | 8 x IEC/10A+ 1 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 441 x 86 x 647 | 35.3 | 2/2 | W1005WEB | W3005WEB | - |
Eaton Ellipse PRO tower | Ellipse PRO 650 FR | ELP650FR | 650 | 400 | 8.5 / 4 / 1.5 | 1 x 12 V / 7 Ah | 4 x FR (3+1) | USB | 82 x 260 x 285 | 6.6 | 3/3 | W1002WEB | W3002WEB | - |
Eaton Ellipse PRO tower | Ellipse PRO 850 FR | ELP850FR | 850 | 510 | 8.5 / 4 / 1.5 | 1 x 12 V / 9 Ah | 4 x FR (3+1) | USB | 82 x 260 x 285 | 7.3 | 3/3 | W1002WEB | W3002WEB | - |
Eaton Ellipse PRO tower | Ellipse PRO 1200 FR | ELP1200FR | 1200 | 750 | 9 / 4 / 2 | 2 x 12 V / 7 Ah | 8 x FR (4+4) | USB | 82 x 275 x 390 | 9.8 | 3/3 | W1002WEB | W3002WEB | - |
Eaton Ellipse PRO tower | Ellipse PRO 1600 FR | ELP1600FR | 1600 | 1000 | 9 / 4 / 1.5 | 2 x 12 V / 9 Ah | 8 x FR (4+4) | USB | 82 x 275 x 390 | 11.3 | 3/3 | W1003WEB | W3003WEB | - |
Eaton 5P Gen2 tower | Eaton 5P 650i G2 | 5P650IG2 | 650 | 520 | 9.4 / 3 / 1.1 | 1 x 12 V / 9 Ah | 4 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 150 x 233 x 345 | 7.9 | 3/2 | W1003WEB | W3003WEB | - |
Eaton 5P Gen2 tower | Eaton 5P 850i G2 | 5P850IG2 | 850 | 680 | 13.3 / 7.3 / 4.8 | 2 x 12 V / 7 Ah | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 150 x 233 x 345 | 10.2 | 3/2 | W1003WEB | W3003WEB | - |
Eaton 5P Gen2 tower | Eaton 5P 1150i G2 | 5P1150IG2 | 1150 | 920 | 11.4 / 5.9 / 3.1 | 2 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 150 x 233 x 345 | 11 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 tower | Eaton 5P 1550i G2 | 5P1550IG2 | 1550 | 1350 | 11.6 / 5.2 / 2 | 3 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 150 x 233 x 445 | 15.1 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 650i Rack 1U G2 | 5P650IR1UG2 | 650 | 520 | 7.2 / 3 / 1.1 | 2 x 6 V / 9 Ah | 4 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 361 | 8.6 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 850i Rack 1U G2 | 5P850IR1UG2 | 850 | 680 | 13.2 / 6.8 / 3.9 | 4 x 6 V / 7 Ah | 4 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 509 | 13.7 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 1150i Rack 1U G2 | 5P1150IR1UG2 | 1150 | 920 | 12.5 / 5 / 3.2 | 4 x 6 V / 9 Ah | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 509 | 14.2 | 3/2 | W1005WEB | W3005WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 1550i Rack 1U G2 | 5P1550IR1UG2 | 1550 | 1350 | 13.5 / 5.6 / 2.1 | 6 x 6 V / 9 Ah | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 555 | 18.7 | 3/2 | W1005WEB | W3005WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 650i Rack 1U Netpack G2 | 5P650IRNG2 | 650 | 520 | 7.2 / 3 / 1.1 | 2 x 6 V / 9 Ah | 4 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 361 | 8.6 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 850i Rack 1U Netpack G2 | 5P850IRNG2 | 850 | 680 | 13.2 / 6.8 / 3.9 | 4 x 6 V / 7 Ah | 4 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 509 | 13.7 | 3/2 | W1004WEB | W3004WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 1150i Rack 1U Netpack G2 | 5P1150IRNG2 | 1150 | 920 | 12.5 / 5 / 3.2 | 4 x 6 V / 9 Ah | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 509 | 14.2 | 3/2 | W1005WEB | W3005WEB | - |
Eaton 5P Gen2 rack | Eaton 5P 1550i Rack 1U Netpack G2 | 5P1550IRNG2 | 1550 | 1350 | 13.5 / 5.6 / 2.1 | 6 x 6 V / 9 Ah | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 555 | 18.7 | 3/2 | W1005WEB | W3005WEB | - |
Eaton 5P rack | 5P 1550g Rack 1U | 5P1550GR-L | 1550 | 1100 | 11 / 6.5 / 4 | LiFePO4 | 6 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 43 x 554 | 15.8 | 5/5 | W1006WEB | W3006WEB | - |
Eaton 5PX Gen2 rack/tower | 5PX 1000i RT2U G2 | 5PX1000IRT2UG2 | 1000 | 1000 | 17 / 9 / 6 | 4 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 448 | 19.6 | 3/2 | W1004WEB | W3004WEB | 5PXEBM48RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 1000i RT2U Netpack G2 | 5PX1000IRTNG2 | 1000 | 1000 | 17 / 9 / 6 | 4 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 448 | 19.6 | 3/2 | W1004WEB | W3004WEB | 5PXEBM48RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 1500i RT2U G2 | 5PX1500IRT2UG2 | 1500 | 1500 | 14 / 8 / 5 | 4 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 448 | 22.4 | 3/2 | W1004WEB | W3004WEB | 5PXEBM48RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 1500i RT2U Netpack G2 | 5PX1500IRTNG2 | 1500 | 1500 | 14 / 8 / 5 | 4 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 448 | 22.4 | 3/2 | W1004WEB | W3004WEB | 5PXEBM48RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 2200i RT2U G2 | 5PX2200IRT2UG2 | 2200 | 2200 | 10 / 5 / 3 | 6 x 12 V / 7 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 603 | 28.2 | 3/2 | W1005WEB | W3005WEB | 5PXEBM72RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 2200i RT2U Netpack G2 | 5PX2200IRTNG2 | 2200 | 2200 | 10 / 5 / 3 | 6 x 12 V / 7 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 603 | 28.2 | 3/2 | W1005WEB | W3005WEB | 5PXEBM72RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 2200i RT3U G2 | 5PX2200IRT3UG2 | 2200 | 2200 | 10 / 5 / 3 | 6 x 12 V / 7 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 129 x 483 | 27.5 | 3/2 | W1005WEB | W3005WEB | 5PXEBM72RT3UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 3000i RT2U G2 | 5PX3000IRT2UG2 | 3000 | 3000 | 9 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 603 | 31.7 | 3/2 | W1006WEB | W3006WEB | 5PXEBM72RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 3000i RT2U Netpack G2 | 5PX3000IRTNG2 | 3000 | 3000 | 9 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 85.5 x 603 | 31.7 | 3/2 | W1006WEB | W3006WEB | 5PXEBM72RT2UG2 |
Eaton 5PX Gen2 rack/tower | 5PX 3000i RT3U G2 | 5PX3000IRT3UG2 | 3000 | 3000 | 9 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A+ 2 x IEC/16A | USB/RS-232/ROO/RPO/MS slot | 438 x 129 x 483 | 31.1 | 3/2 | W1006WEB | W3006WEB | 5PXEBM72RT3UG2 |
Eaton 9E tower | 9E 1000i | 9E1000I | 1000 | 800 | 11.5 / 6.5 / 4.5 | 2 x 12 V / 9 Ah | 4 x IEC/10A | USB/RS-232/MS slot | 144 x 228 x 356 | 9.5 | 2/2 | W1003WEB | - | - |
Eaton 9E tower | 9E 2000i | 9E2000I | 2000 | 1600 | 16.5 / 10 / 6.5 | 6 x 12 V / 7 Ah | 6 x IEC/10A | USB/RS-232/MS slot | 190 x 330 x 399 | 22.4 | 2/2 | W1004WEB | - | 9EEBM72 |
Eaton 9E tower | 9E 3000i | 9E3000I | 3000 | 2400 | 13.5 / 7 / 5 | 6 x 12 V / 9 Ah | 6 x IEC/10A + 1 x IEC/16A | USB/RS-232/MS slot | 190 x 330 x 399 | 24.2 | 2/2 | W1004WEB | - | 9EEBM72 |
Eaton 9E rack | 9E 1000i Rack 2U | 9E1000IR | 1000 | 900 | 15 / 8 / 6 | 3 x 12 V / 9 Ah | 4 x IEC/10A | USB/RS-232/RPO/MS slot | 438 x 86.5 x 438 | 17.6 | 2/2 | W1003WEB | - | - |
Eaton 9E rack | 9E 2000i Rack 2U | 9E2000IR | 2000 | 1800 | 12 / 6 / 4.5 | 6 x 12 V / 7 Ah | 6 x IEC/10A | USB/RS-232/RPO/MS slot | 438 x 86.5 x 608 | 29.9 | 2/2 | W1004WEB | - | 9EEBM72R |
Eaton 9E rack | 9E 3000i Rack 2U | 9E3000IR | 3000 | 2700 | 10.5 / 5 / 3.2 | 6 x 12 V / 9 Ah | 6 x IEC/10A + 1 x IEC/16A | USB/RS-232/RPO/MS slot | 438 x 86.5 x 608 | 31.3 | 2/2 | W1005WEB | - | 9EEBM72R |
Eaton 9SX tower | 9SX 700i | 9SX700I | 700 | 630 | 13.5 / 8 / 5 | 2 x 12 V / 9 Ah | 6 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 160 x 252 x 357 | 11.5 | 2/2 | W1003WEB | W3003WEB | - |
Eaton 9SX tower | 9SX 1000i | 9SX1000I | 1000 | 900 | 16.5 / 9 / 6 | 3 x 12 V / 9 Ah | 6 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 160 x 252 x 387 | 14.8 | 2/2 | W1004WEB | W3004WEB | 9SXEBM36T |
Eaton 9SX tower | 9SX 1500i | 9SX1500I | 1500 | 1350 | 16 / 9 / 5.5 | 4 x 12 V / 9 Ah | 6 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 160 x 252 x 437 | 18.5 | 2/2 | W1004WEB | W3004WEB | 9SXEBM48T |
Eaton 9SX tower | 9SX 2000i | 9SX2000I | 2000 | 1800 | 20 / 11 / 7 | 8 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 214 x 346 x 412 | 33.3 | 2/2 | W1004WEB | W3004WEB | 9SXEBM96T |
Eaton 9SX tower | 9SX 3000i | 9SX3000I | 3000 | 2700 | 15.5 / 8.5 / 6 | 8 x 12 V / 9 Ah | 8 x IEC/10A + 1 x IEC/16A | USB/RS-232/RO/RPO/MS slot | 214 x 346 x 412 | 33.4 | 2/2 | W1005WEB | W3005WEB | 9SXEBM96T |
Eaton 9SX tower | 9SX 5000i | 9SX5KI | 5000 | 4500 | 21 / 13 / 8 | 20 x 12 V / 7 Ah | Terminal block | USB/RS-232/RO/RPO/MS slot | 244 x 575 x 542 | 65.5 | 2/2 | W1006WEB | W3006WEB | 9SXEBM240T |
Eaton 9SX tower | 9SX 6000i | 9SX6KI | 6000 | 5400 | 16.5 / 9.5 / 6 | 20 x 12 V / 7 Ah | Terminal block | USB/RS-232/RO/RPO/MS slot | 244 x 575 x 542 | 65.5 | 2/2 | W1006WEB | W3006WEB | 9SXEBM240T |
Eaton 9SX rack | 9SX 1000i Rack 2U | 9SX1000IR | 1000 | 900 | 16.5 / 9 / 6 | 3 x 12 V / 9 Ah | 6 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 438 x 86.5 x 438 | 15.7 | 2/2 | W1004WEB | W3004WEB | 9SXEBM36R |
Eaton 9SX rack | 9SX 1500i Rack 2U | 9SX1500IR | 1500 | 1350 | 16 / 9 / 5.5 | 4 x 12 V / 9 Ah | 6 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 438 x 86.5 x 438 | 18.4 | 2/2 | W1004WEB | W3004WEB | 9SXEBM48R |
Eaton 9SX rack | 9SX 2000i Rack 2U | 9SX2000IR | 2000 | 1800 | 12 / 6.5 / 4.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/RO/RPO/MS slot | 438 x 86.5 x 608 | 26.5 | 2/2 | W1005WEB | W3005WEB | 9SXEBM72R |
Eaton 9SX rack | 9SX 3000i Rack 2U | 9SX3000IR | 3000 | 2700 | 10.5 / 5.5 / 3.5 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 1 x IEC/16A | USB/RS-232/RO/RPO/MS slot | 438 x 86.5 x 608 | 26.5 | 2/2 | W1005WEB | W3005WEB | 9SXEBM72R |
Eaton 9SX Gen2 rack/tower | 9SX 5000i RT3U G2 | 9SX5KIRT3UG2 | 5000 | 5000 | 9.4 / 6 / 3.5 | 15 x 12 V / 5 Ah | Terminal block + 8 x IEC/10A + 3 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 684 | 43.1 | 2/2 | W1007WEB | W3007WEB | 9SXEBM180RT3UG2 |
Eaton 9SX Gen2 rack/tower | 9SX 6000i RT3U G2 | 9SX6KIRT3UG2 | 6000 | 6000 | 7.1 / 4.6 / 2.6 | 15 x 12 V / 5 Ah | Terminal block + 8 x IEC/10A + 3 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 684 | 43.1 | 2/2 | W1007WEB | W3007WEB | 9SXEBM180RT3UG2 |
Eaton 9SX Gen2 rack/tower | 9SX 8000i RT4U G2 | 9SX8KIRT4UG2 | 8000 | 8000 | 10.6 / 6.4 / 3.5 | 20 x 12 V / 7 Ah | Terminal block + 8 x IEC/10A + 4 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 174 x 725 | 78.8 | 2/2 | W1008WEB | W3008WEB | 9SXEBM240RT3UG2 |
Eaton 9SX Gen2 rack/tower | 9SX 11000i RT4U G2 | 9SX11KIRT4UG2 | 11000 | 11000 | 6.3 / 3.7 / 1.9 | 20 x 12 V / 7 Ah | Terminal block + 8 x IEC/10A + 4 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 174 x 725 | 78.8 | 2/2 | W1008WEB | W3008WEB | 9SXEBM240RT3UG2 |
Eaton 9PX rack/tower | 9PX 1000i RT2U | 9PX1000IRT2U | 1000 | 1000 | 16 / 9 / 6 | 4 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 450 | 17.4 | 3/2 | W1004WEB | W3004WEB | 9PXEBM48RT2U |
Eaton 9PX rack/tower | 9PX 1000i RT2U Netpack | 9PX1000IRTN | 1000 | 1000 | 16 / 9 / 6 | 4 x 12 V / 7 Ah | 8 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 450 | 17.4 | 3/2 | W1004WEB | W3004WEB | 9PXEBM48RT2U |
Eaton 9PX rack/tower | 9PX 1500i RT2U | 9PX1500IRT2U | 1500 | 1500 | 14 / 8 / 5 | 4 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 450 | 18.9 | 3/2 | W1005WEB | W3005WEB | 9PXEBM48RT2U |
Eaton 9PX rack/tower | 9PX 1500i RT2U Netpack | 9PX1500IRTN | 1500 | 1500 | 14 / 8 / 5 | 4 x 12 V / 9 Ah | 8 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 450 | 18.9 | 3/2 | W1005WEB | W3005WEB | 9PXEBM48RT2U |
Eaton 9PX rack/tower | 9PX 2200i RT2U | 9PX2200IRT2U | 2200 | 2200 | 10 / 5.5 / 3.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 25.0 | 3/2 | W1005WEB | W3005WEB | 9PXEBM72RT2U |
Eaton 9PX rack/tower | 9PX 2200i RT2U Netpack | 9PX2200IRTN | 2200 | 2200 | 10 / 5.5 / 3.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 25.0 | 3/2 | W1005WEB | W3005WEB | 9PXEBM72RT2U |
Eaton 9PX rack/tower | 9PX 2200i RT3U | 9PX2200IRT3U | 2200 | 2200 | 10 / 5.5 / 3.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 24.5 | 3/2 | W1005WEB | W3005WEB | 9PXEBM72RT3U |
Eaton 9PX rack/tower | 9PX 2200i RT3U HotSwap IEC | 9PX2200IRTBP | 2200 | 2200 | 10 / 5.5 / 3.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A + 2 x IEC/16A + 6 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 24.5 | 3/2 | W1005WEB | W3005WEB | 9PXEBM72RT3U |
Eaton 9PX rack/tower | 9PX 2200i RT3U HotSwap HW | 9PX2200IRTBPH | 2200 | 2200 | 10 / 5.5 / 3.5 | 6 x 12 V / 7 Ah | 8 x IEC/10A + 2 x IEC/16A + Terminal block | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 24.5 | 3/2 | W1005WEB | W3005WEB | 9PXEBM72RT3U |
Eaton 9PX rack/tower | 9PX 3000i RT2U | 9PX3000IRT2U | 3000 | 3000 | 9.5 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 27.6 | 3/2 | W1006WEB | W3006WEB | 9PXEBM72RT2U |
Eaton 9PX rack/tower | 9PX 3000i RT2U Netpack | 9PX3000IRTN | 3000 | 3000 | 9.5 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 27.6 | 3/2 | W1006WEB | W3006WEB | 9PXEBM72RT2U |
Eaton 9PX rack/tower | 9PX 3000i RT3U | 9PX3000IRT3U | 3000 | 3000 | 9.5 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 27.4 | 3/2 | W1006WEB | W3006WEB | 9PXEBM72RT3U |
Eaton 9PX rack/tower | 9PX 3000i RT3U HotSwap IEC | 9PX3000IRTBP | 3000 | 3000 | 9.5 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 2 x IEC/16A + 6 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 27.4 | 3/2 | W1006WEB | W3006WEB | 9PXEBM72RT3U |
Eaton 9PX rack/tower | 9PX 3000i RT3U HotSwap HW | 9PX3000IRTBPH | 3000 | 3000 | 9.5 / 5 / 3 | 6 x 12 V / 9 Ah | 8 x IEC/10A + 2 x IEC/16A + Terminal block | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 485 | 27.4 | 3/2 | W1006WEB | W3006WEB | 9PXEBM72RT3U |
Eaton 9PX Gen2 | 9PX 5000i RT3U HotSwap Net | 9PX5KIRTNBPG2 | 5000 | 5000 | 9.4 / 6 / 3.5 | 15 x 12 V / 5 Ah | Terminal block + 6 x IEC/10A + 6 x IEC/10/16A (C39) | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 684 | 45.1 | 3/2 | W1008WEB | W3008WEB | 9PXEBM180RT3UG2 |
Eaton 9PX Gen2 | 9PX 6000i RT3U HotSwap Net | 9PX6KIRTNBPG2 | 6000 | 6000 | 7.1 / 4.6 / 2.6 | 15 x 12 V / 5 Ah | Terminal block + 6 x IEC/10A + 6 x IEC/10/16A (C39) | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 684 | 45.1 | 3/2 | W1008WEB | W3008WEB | 9PXEBM180RT3UG2 |
Eaton 9PX Gen2 | 9PX 8000i RT4U HotSwap Net | 9PX8KIRTNBPG2 | 8000 | 8000 | 15.2 / 9.7 / 5.4 | 20 x 12 V / 9 Ah | Terminal block + 8 x IEC/10A + 8 x IEC/10/16A (C39) | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 174 x 725 | 83.4 | 3/2 | W1008WEB | W3008WEB | 9PXEBM240RT3UG2 |
Eaton 9PX Gen2 | 9PX 11000i RT4U HotSwap Net | 9PX11KIRTNBPG2 | 11000 | 11000 | 9.4 / 5.8 / 3.1 | 20 x 12 V / 9 Ah | Terminal block + 8 x IEC/10A + 8 x IEC/10/16A (C39) | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 174 x 725 | 83.4 | 3/2 | W1008WEB | W3008WEB | 9PXEBM240RT3UG2 |
Eaton 9PX 3:1 | 9PX 6000i 3:1 HotSwap | 9PX6KIBP31 | 6000 | 5400 | 30 / 20 / 11 | 15 x 12 V / 5 Ah | Terminal block + 4 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 260 x 700 | 88.0 | 2/2 | W1008WEB | W3008WEB | 9PXEBM240 |
Eaton 9PX 3:1 | 9PX 8000i 3:1 HotSwap | 9PX8KIBP31 | 8000 | 7200 | 20 / 15 / 8 | 20 x 12 V / 9 Ah | Terminal block + 4 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 260 x 700 | 88.0 | 2/2 | W1008WEB | W3008WEB | 9PXEBM240 |
Eaton 9PX 3:1 | 9PX 11000i 3:1 HotSwap | 9PX11KIBP31 | 11000 | 10000 | 13 / 9 / 5 | 20 x 12 V / 9 Ah | Terminal block + 4 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 260 x 700 | 88.0 | 2/2 | W1008WEB | W3008WEB | 9PXEBM240 |
Eaton 9PX Li-Ion | 9PX 1500i RT2U Netpack Li-Ion | 9PX1500IRTN-L | 1500 | 1500 | 21.5 / 14 / 10.5 | LFP module | 8 x IEC/10A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 450 | 15.8 | 5 | W1006WEB | W3006WEB | 9PXEBM48RT1U-L |
Eaton 9PX Li-Ion | 9PX 2200i RT2U Netpack Li-Ion | 9PX2200IRTN-L | 2200 | 2200 | 23 / 15 / 11.5 | LFP module | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 22.1 | 5 | W1007WEB | W3007WEB | 9PXEBM72RT1U-L |
Eaton 9PX Li-Ion | 9PX 3000i RT2U Netpack Li-Ion | 9PX3000IRTN-L | 3000 | 3000 | 20.5 / 14 / 10.5 | LFP module | 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 86.5 x 605 | 22.1 | 5 | W1008WEB | W3008WEB | 9PXEBM72RT1U-L |
Eaton 9PX Li-Ion | 9PX 6000i RT3U Netpack Li-Ion | 9PX6KIRTN-L | 6000 | 5400 | 20 / 13.5 / 10 | LFP module | Terminal block + 8 x IEC/10A + 2 x IEC/16A | USB/RS-232/RO/ROO/RPO/MS slot | 440 x 130 x 685 | 36.9 | 5 | W1008WEB | W3008WEB | 9PXEBM192RT2U-L |
Accessories and Services
EatonCare Extended Warranty
Eaton offers extended warranty services to prolong the protection of your UPS devices:
- Warranty+1 / Warranty+3: Extends the standard warranty by 1 or 3 years, including remote monitoring and professional technical support.
- Connected Warranty+1 / Connected Warranty+3: Includes all benefits of extended warranty plus cybersecure monitoring, regular status reports, faster warranty replacements through remote diagnostics, and professional technical support. Can be extended up to a maximum of seven years.
Registration of the product and purchased service is required on the Eaton website (www.eaton.eu/registration) to activate these services.
Accessories
- Cloud Card: For cloud-based UPS monitoring.
- Communication Cards: Gigabit Network Card, Industrial ModBus Card, Relay Card-MS for various communication needs.
- Environmental Monitoring Probe (EMP Gen2): For monitoring environmental conditions.
- Hotswap MBP: Maintenance bypass switch for UPS maintenance or upgrades without load interruption. Available for various power ratings and configurations (FR, IEC, Terminal block).