Important Warning and Safety Instructions

All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property.

Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product.

Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods.

Any figures or estimates given for performance of goods are based upon the company's experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls.

Please keep this setup instruction for future reference.

Installed by: _______________________________________

Service date: ______________________________________

Features

  • Cost effective solution for domestic sliding gates
  • Self learning using intelligent positioning technology
  • High capacity Lithium-ion battery backup optional
  • All metal gearbox for longer life
  • Suitable for gates up to 900Kg
  • Contactless limit switch
  • Soft start and soft stop
  • Easy installation with Eclipse® control card
  • Designed by Elsema in Australia

Description

Designed by Elsema, the AXIOM series of automatic gate opener is setting new standards in the automatic gate industry. With Lithium battery backup and all the great features at a competitive price, the AXIOM motor kit is your best choice.

Features such as Soft-start, Soft-stop, adjustable anti-crush, inputs for automatic vehicle detection, wireless keypads, safety beams, intercom systems and GSM gate opener, makes it ideal for all domestic and light industrial installations.

Lithium-ion batteries have a higher charge/discharge cycle, are smaller in size and has a longer service life when compared with normal lead acid batteries.

The AXIOM motor kits are operated by the Eclipse® Operating System (EOS). It is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs.

Elsema's easy options to add remote controls or any other accessory makes for a very user friendly approach, while avoiding the lockdown approach.

The Axiom motor kits are designed in Australia for Australian conditions.

Part Number

Part No. Contents Part No. Contents
iS600 Standard iS600 Kit includes 4metres or gear rack, 3 x FOB remotes and Photo Electric Beam iS900 Standard iS900 Kit includes 4metres or gear rack, 3 x FOB remotes and Photo Electric Beam
iS900B Standard iS900 Kit with Li-ion Battery Backup Pack
Solar Gates iS900Solar24 Solar kit includes iS900 motor, solar MPPT charger Li-ion Battery and a 24Volt 40W solar panel.

Connection Diagram

The connection diagram illustrates the main control board and its terminals. Key connections include:

  • AC Supply (x2 terminals)
  • Motor (x2 terminals)
  • Battery + and Battery - terminals
  • Push Button terminal
  • Open terminal
  • Common terminal
  • Close terminal
  • Stop terminal
  • Common terminal
  • PED Access terminal
  • Photo Beam terminal
  • Common terminal
  • + 12 VDC terminal
  • - 12 VDC terminal
  • Output 1 C (Common)
  • Output 1 NO (Normally Open)
  • Output 1 NC (Normally Closed)
  • Fuse indicator
  • Relay terminal block
  • Built-in Receiver section with Program 1, Program 2, Antenna 1, Shield, Antenna 2
  • Master Control knob
  • Limit Switch terminal
  • Output 2 terminal, used with Relay 1-12

Note: The 'Normally Open' and 'Normally Closed' inputs for PED Access and Photo Beam can be changed by the user.

Output is rated at 250mA.

Electrical Wiring - Supply, Motors and Inputs

DANGER: Always switch off power before doing any wiring. Make sure that all the wiring is completed and that the motor is connected to the control card. Recommended wire strip length should be 12mm for all connections to the plug-in terminal blocks.

The diagram shows the supply, motors, and inputs available and the factory default setting for each input. The control board features a Fuse, Relay, Master Control, and the Eclipse Operating System.

Input terminals include:

  • Push Button (Open, Common, Close, Stop, Common)
  • PED Access
  • Photo Beam
  • Common
  • + 12 VDC
  • - 12 VDC
  • Output 1 C, Output 1 NO, Output 1 NC

Input configurations for PED Access and Photo Beam can be set as Normally Open or Normally Closed.

Output is rated at 250mA.

Setup i-Learning Steps:

  1. The i-Learning setup can always be interrupted with the stop button or by pressing the Master Control knob.
  2. Enter Menu 11 to start i-Learning, or new control cards will automatically prompt you to do the i-Learning.
  3. Look at the LCD and follow the instructions displayed.
  4. A buzzer will indicate learning was successful. If there was no buzzer, check all electrical wiring, including the power supply, then go back to step 1.
  5. If you hear the buzzer after the i-Learn, the gate or door is ready for use.

Accessories

Solar Applications

For solar use the iS900Solar24.

Pre-made Inductive Loops & Loop Detectors

Elsema has a range of Saw-Cut and Direct Burial loops. They are pre-formed with recommended loop sizes for commercial or domestic applications and makes installation quick and easy.

Wireless Bump Strip

Safety edge bump strip is installed on the moving gate or barrier along with the transmitter. When the gate hits an obstacle, the transmitter transmits a wireless signal to the receiver to stop the gate from causing further damage.

Flashing Lights

Elsema has several flashing lights to act as a warning when the gate or doors is in operation.

Electromagnetic Locks

Waterproof magnetic lock for electronic sliding and swing gates. 12 or 24 Volts DC supply can be used. The lock is magnetised when voltage is applied.

Diagram Description: Images of Inductive Loop, Loop Detectors, Safety Bump Strip, Flashing Lights, and Magnetic Locks.

Keyring Remotes

The latest PentaFOB® keyring remotes ensure your gates or doors are secure. Visit www.elsema.com for more details.

Diagram Description: Images of various PentaFOB® remotes.

PentaFOB® Programmer

Add, edit and delete PentaFOB® remotes from the receiver's memory. The receiver can also be password protected from unauthorised access.

Diagram Description: Image of PentaFOB® Programmer.

Booster for PentaFOB® remotes

Penta Repeater can increase the operating range of the keyring remotes to up to 500 metres.

Diagram Description: Image of Penta Repeater/booster.

PentaFOB® Programming Instructions

  1. Press and hold the program button on the built-in receiver (Refer to the iS connection diagram).
  2. Press the remote button for 2 seconds while holding the program button on the receiver.
  3. Receiver LED will flash and then turn Green.
  4. Release the button on the receiver.
  5. Press remote control button to test the receiver output.

Deleting Receivers Memory

Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver's memory.

PentaFOB® Programmer

This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access.

PentaFOB® Backup Chips

This chip is used to backup or restore the contents of a receiver. When there are 100s of remotes programmed to a receiver, the installer normally backs up the receiver memory in case the receiver is damaged.

LCD Display Explained

The LCD display provides information on Gate Status, Limit Switch Status, and Input Status.

Status Type Indicator Description
Gate Status Gate Opened Gate is in the fully open position
Gate Closed Gate is in the fully close position
Gate Stopped Gate has been stopped by either one of the inputs or remote control
Obstruction Detected Control card has sensed an obstruction
Limit Switch Status M1OpnLmON Motor 1 Open limit switch is ON
M1ClsLmON Motor 1 Close limit switch is ON
Input Status Opn ON Open input is activated
Cls ON Close input is activated
Stp ON Stop input is activated
PE ON Photo Beam input is activated
PB ON Push Button input is activated
PED ON Pedestrian Access input is activated

Troubleshooting Guide

During i-Learn, the gate will open and close 3 times. First cycle is in slow speed. The second cycle is in fast speed. The third cycle will be in fast speed but the gate will slow down before reaching the end.

Error during i-Learn

Error Remedy
i-Learn is stuck at 14% Decrease M1 Slow Speed Obstruction Margin (Menu 8.3)
i-Learn is stuck at 28% Decrease M1 Open Obstruction Margin (Menu 8.1)
Gate does not fully open or fully close in the 1st i-Learn cycle Increase M1 Slow Speed Obstruction Margin (Menu 8.3)
Gate does not fully open or fully close in the 2nd i-Learn cycle Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)
Limit switch failed to register and the gate is not in the fully open or closed position. For 1st cycle: Increase M1 Slow Speed Obstruction Margin (Menu 8.3). For 2nd & 3rd cycle: Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)
Limit switch failed to register and the gate is in the fully open or closed position. Limit switch position is not correct. The gate has reached the physical stopper before the limit switch is activated.

Error during Operation

Error Remedy
Gate does not fully open or fully close but the LCD says “Gate Opened" or "Gate Closed". Increase M1 Slow Speed Obstruction Margin (Menu 8.3)
LCD says "Obstruction detected" when there is no obstruction. Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)
Gate does not respond to remotes or any local trigger. Check the LCD for Input status (see previous page). If any input is activated and held active, the card will not respond to any other command.

Company Information

ELSEMA PTY LTD
31 Tarlington Place
Smithfield NSW 2164 Australia

P: 02 9609 4668
W: www.elsema.com

Elsema offers a range of gate and door control solutions, including sliding gate motor kits, swinging gate motor kits, and motor control cards & kits. They also provide keyring remotes, programmers, and boosters.

Models: iS900 Axiom Sliding Gate Motor Kit, iS900, Axiom Sliding Gate Motor Kit, Sliding Gate Motor Kit, Gate Motor Kit, Motor Kit, Kit

File Info : application/pdf, 30 Pages, 1.52MB

PDF preview unavailable. Download the PDF instead.

is-manual

References

Adobe PDF Library 17.0 Adobe InDesign 18.3 (Windows)

Related Documents

Preview Elsema Axiom Automatic Sliding Gate Kits - Secure & Reliable Automation
Discover Elsema's Axiom Automatic Sliding Gate Kits (iS600, iS900) for residential and solar-powered installations. Featuring advanced safety, eco-friendly options, and durable components for smooth gate automation.
Preview Elsema iS2000/iS3000 High Speed Sliding Gate Opener User Manual
User manual for Elsema's iS2000 and iS3000 high-speed sliding gate openers, detailing installation, wiring, operation, safety precautions, and maintenance procedures for the Eclipse™ Control Card.
Preview Elsema Gate & Door Controls Catalogue 2014 | Automation Solutions
Discover the comprehensive 2014 Elsema Gate & Door Controls catalogue. Featuring advanced sliding gate motors, swing gate motors, solar gate controllers, remotes, receivers, and accessories for automated gates and doors. Explore selection guides and technical specifications for residential and industrial applications.
Preview Elsema iS1500LV High Speed Sliding Gate Opener User Manual
This user manual provides comprehensive installation, safety, operation, and maintenance instructions for the Elsema iS1500LV High Speed Sliding Gate Opener with Battery Back-Up. Learn about gate automation, including safety precautions, installation steps, and technical details.
Preview Elsema PCKeypad Wired Keypad User Manual - Obsolete Product
Comprehensive user manual for the Elsema PCKeypad wired keypad, covering features, installation, specifications, wiring, programming, and receiver integration. This product is obsolete and has been replaced by WK433.
Preview Elsema GIGALINK 433MHz Handheld Transmitters | GLT433 Series Overview
Comprehensive overview of Elsema GIGALINK 433MHz handheld transmitters (GLT433 series), detailing features, applications, technical specifications, product range, and operational data.
Preview Elsema MCR91503R/MCR91504R: 3/4-Channel 915MHz Frequency Hopping Receivers
Discover the Elsema MCR91503R and MCR91504R, 3 and 4-channel 915MHz receivers featuring frequency hopping and advanced digital coding for secure, interference-free wireless control. Ideal for industrial automation, security, and advanced home automation systems.
Preview Elsema COBO 10 240VAC Double Motor Controller Card
Technical specifications and connection guide for the Elsema COBO 10 240VAC Double Motor Controller Card, designed for automatic gate and door control.