Specifications & Performance Claims
This system has been tested according to NSF/ANSI 42 for the reduction of chlorine taste and odor. The concentration of the indicated substance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42. While testing was performed under standard laboratory conditions, actual performance of the system may vary based on local water conditions.
SPECIFICATIONS
Specification | Model WHELJ1 |
---|---|
Rated Service Flow Rate | 6.0 gpm (22.7 L/min.) |
Pressure Drop at Rated Service Flow | 10 psig* (68.9 kPa) |
Pressure Drop at 9.6 gpm | 15 psig* (103.4 kPa) |
Water Pressure Limits (minimum / maximum) | 30 - 125 psi (206.8 - 861.8 kPa) |
Water Temperature Limits (minimum / maximum) | 40 - 100 °F (5 - 38 °C) |
Drain Flow Rate | 3.4 gpm |
Rated Capacity at Chlorine Concentration** of: | 0.50 ppm: 2,280,000 gal.* 0.75 ppm: 1,520,000 gal.* 1.0 ppm: 1,140,000 gal.* 1.5 ppm: 760,000 gal.* 2.0 ppm: 570,000 gal.* |
Sediment Removal with 30-40 micron particle size | 95% or more |
Sediment Removal with 40-50 micron particle size | 99% or more |
* From independent laboratory test data.
** Typical residential chlorine concentration is 0.5 to 1.0 ppm.
This system conforms to NSF/ANSI Standard 42 for the specific performance claims as verified and substantiated by test data.
PERFORMANCE CLAIMS
Substance | Influent Challenge Level | Reduction Requirement | Average Percent Removal |
---|---|---|---|
Chlorine | 2.0 ±10% mg/L | 50% | 82.8% |