Daikin Room Air Conditioners Operation Manual

Models: FTY25FV1A, FTY25FV1C

Important Cautions of Safety

Read the following warnings and cautions carefully before operating the system and use it correctly. After reading, keep this manual in a place where the actual user can see it whenever necessary.

WARNINGS (Failure to follow a warning is very likely to result in such grave consequences as death or serious injury.)

Caution

(Failure to follow a caution may result in serious injury or property damage, and in certain conditions, may result in a grave consequence.)

Unit Operation Panel and Display Panel

OPERATION indicator lamp (green): Lights up on system activation irrespective of operation mode.

TIMER indicator lamp (green): Lights up when "TIMER ON" or "TIMER OFF" countdown is in progress.

Signal receiver: Receives signals from the remote controller.

Temperature sensor: Monitors room temperature.

ON/OFF button: [Power Button]

Remote Control Operation

SIGNAL TRANSMITTER: Send signals to the air conditioner.

Note: Display monitor function. You can check or change settings when the air conditioner is stopped. To check, press once the button for the setting you are checking. To change the setting, press the same button again while the display is ON.

Treatment

Caution

Replacing of Air Purifying Filter

Soiled Air Purifying Filter needs replacing. Air Purifying Filter should be replaced every three months on average, but if their colour is similar to either of the sample colours, replace them promptly.

How to replace

  1. Hold the handle at the bottom center of the air filter, and pull it down.
  2. Make sure that the net-side (black) of the filter is facing front (up) in the fig. When setting the frame, the arrows marked on the claws should be pointing upward. Set 3 claws at the top of the frame first, and then set the rest of 2 claws at the bottom.
  3. Be sure to set air filters back in place. Look at page 23 for replacing of air purifying filters.

Please consult the shop you purchased this product for Air Purifying Filter replacement.

Parts Name | Code Name

Air Purifying filter (with frame) | KAF96A41

Air Purifying filter (without frame) | KAF96A42

Note:

PROGRAM DRY Operation

By the microcomputer function, the air conditioner takes away the moisture with minimum temperature decrease.

  1. Set the mode to "¨" (PROGRAM DRY).
  2. Press ON/OFF button. Then the OPERATION indicator lamp lights up.

To stop: Press ON/OFF button. Then OPERATION indicator lamp goes out.

This is a microcomputer controlled function that determines the appropriate room temperature and humidity, and cycles the compressor and indoor fan ON and OFF to achieve and maintain them, based on the ambient temperature and humidity at the time of switching on this function.

Note:

THREE-STEP Flow system

  1. Step 1: At the start of HEAT mode, the air blows out horizontally.
  2. Step 2: When the air temperature has risen, the unit starts warming up the floor.
  3. Step 3: When the flow and the walls are warmed up, the warm air starts blowing toward the area around people.

Left/Right air flow direction adjustment: The vertical louvers may be adjusted as you please.

Note: If adjustment is carried out during flap swing, the flap may strike your hand. Make adjustments once the swing has completely stopped to the appropriate position.

When the TIMER OFF is set

1. The microcomputer controls the room temperature to ensure your comfortable sleep.

2. The air flow setting can be changed as you like.

The temperature setting changes as shown below after TIMER OFF is set.

COOLING

HEATING

Operation by unit's ON/OFF button

In case you can not operate the air conditioner immediately because of a remote controller trouble or battery exhaustion, you can operate it by ON/OFF button.

Press ON/OFF button: Automatic operation starts at the preset temperature of 25°C with air flow rate automatic.

To stop: Press ON/OFF button once again.

Operating Condition

Use the system in the following temperature and humidity range for safe and effective operation.

COOL Outdoor temperature: 19°C to 46°C Indoor temperature: 18°C to 32°C Indoor humidity: 80% or below
PROGRAM DRY
HEAT Outdoor temperature: -10°C to 21°C Indoor temperature: Under 28°C

Caution

  1. If the temperature or humidity is beyond these conditions, safety devices may work and conditioner may not operate.
  2. Long time operation in a humidity over 80% may cause condensation on the unit and dripping.

Trouble Shooting

The following cases are not air conditioner troubles.

Check Before Calling a Repairperson

If the trouble remains even after checking the following points, do not attempt to repair the air conditioner by yourself but consult the electric appliance shop.

1. The air conditioner does not operate.

2. Does not sufficiently cool or heat.

3. The OPERATION lamp on the unit flashes on and off.

WARNING: CALL THE SHOP IMMEDIATELY.

If one of the following symptoms takes place, stop the operation immediately; then turn the breaker OFF and call the electric appliance shop.

Models: FTY25FV1A, FTY25FV1C, Room Air Conditioners

PDF preview unavailable. Download the PDF instead.

FTY25FV1AC-operation-manual 0 GPL Ghostscript 9.52

Related Documents

Preview Daikin Room Air Conditioners FTXP50M2V1B, FTXP60M2V1B, FTXP71M2V1B Operation Manual
This operation manual provides detailed instructions for the Daikin FTXP50M2V1B, FTXP60M2V1B, and FTXP71M2V1B room air conditioners. It covers installation, operation, maintenance, and troubleshooting.
Preview Daikin Factbox 2025: A Global Leader in HVAC Technology
Discover the Daikin Factbox 2025, detailing Daikin's global leadership in heating, cooling, ventilation, air purification, and refrigerant technology. Explore their extensive product range, commitment to sustainability, and innovation in HVAC-R solutions for residential, commercial, and industrial applications.
Preview Daikin VRV SYSTEM Inverter Air Conditioners: Operation, Installation & Maintenance Guide
Comprehensive operation manual for Daikin VRV SYSTEM Inverter Air Conditioners (FXMQ72TAVJU, FXMQ96TAVJU). Includes safety precautions, installation guidelines, and maintenance instructions.
Preview Daikin VRV System Inverter Air Conditioners Operation Manual
Operation manual for Daikin VRV System Inverter Air Conditioners (Floor standing and Concealed floor standing types). Includes safety considerations, maintenance instructions, and parts identification for models FXLQ12MVJU, FXLQ18MVJU, FXLQ24MVJU, FXNQ12MVJU, FXNQ18MVJU, FXNQ24MVJU.
Preview Daikin Room Air Conditioner Operation Manual: JTKJ Series
Comprehensive operation manual for Daikin Room Air Conditioners, JTKJ Series (JTKJ35UV16WA, JTKJ50UV16VA, JTKJ60UV16UA). Learn about features like Intelligent Eye, Flash Streamer, Wi-Fi connectivity, and detailed operating instructions, safety precautions, and maintenance.
Preview Daikin VRV System Inverter Air Conditioners Operation Manual - FXHQ Series
Comprehensive operation manual for Daikin VRV System Inverter Air Conditioners, FXHQ series (FXHQ12MVJU, FXHQ24MVJU, FXHQ36MVJU). Includes safety precautions, parts identification, and maintenance instructions.
Preview Daikin Room Air Conditioner Operation Manual - FTKR35UV16WAA, FTKR50UV16VKA
Comprehensive operation manual for Daikin Room Air Conditioners, models FTKR35UV16WAA and FTKR50UV16VKA. Covers smart control, Wi-Fi, operation modes, safety, and troubleshooting.
Preview Daikin Room Air Conditioner Operation Manual
This operation manual provides detailed instructions for operating and maintaining Daikin Room Air Conditioners, including features, basic operations, useful functions, timer operations, care and cleaning, and troubleshooting. Model numbers include FTX09NMVJU, FTX12NMVJU, FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTXN09NMVJU, FTXN12NMVJU, FTXN18NMVJU, and FTXN24NMVJU.