TROTEC TDS 75 R / TDS 120 R Electric Heater

Original Instructions

Safety Information

General Warnings:

Specific Warnings:

Foreseeable Misuse:

Personnel Qualifications: Users must be aware of dangers with electric devices in damp areas and have read/understood the instructions.

Symbols on the device: A symbol indicates it is prohibited to place objects (such as towels, clothes etc.) above or directly in front of the device to avoid overheating and fire hazards. ⚡️ (Warning of electrical voltage), ? (Warning of hot surface), ⚠️ (Warning), ⚠️ (Caution), ℹ️ (Note), ℹ️ (Info), ? (Follow the manual).

Residual Risks:

Behaviour in the event of an emergency: 1. Switch off. 2. Disconnect from mains (hold plug). 3. Do not reconnect defective devices.

Overheating Protection: The device has a safety thermostat that switches it off automatically if it overheats. Allow to cool down before investigating the cause.

Information about the Device

Device Description: The electric heater generates and distributes warm air in interior spaces using a heating element and a fan. It features an integrated thermostat for constant warm air flow and a time-delay thermostat for automatic rundown operation. Fan-only operation is also possible.

Device Depiction:

TDS 75 R: Shows the heater with numbered parts: 1. Transport handle, 2. Foot, 3. Air outlet, 4. Selection switch (ventilation/heating levels), 5. Rotary switch (temperature), 6. Air inlet.

TDS 120 R: Shows the heater with carriage construction. Numbered parts: 7. Carriage construction, 8. Wheels, 9. Air outlet, 10. Rotary switch (temperature), 11. Selection switch (ventilation/heating levels), 12. Air inlet.

Transport and Storage

Note: Improper storage or transport can damage the device.

Transport: Fitted with a carry handle. Before transporting: switch off, unplug by holding the plug, do not drag by the cable, allow to cool down.

Storage: Before storing: unplug by holding the plug, allow to cool down. Store in a dry place, protected from frost and heat, upright, protected from dust and direct sunlight. Use a cover if necessary. Do not place other devices or objects on top.

Assembly and Start-up

Scope of Delivery:

Unpacking: Open box, remove device, remove packaging, fully unwind power cable, checking for damage.

Assembly: Use suitable tools.

Mounting the transport handle (TDS 75 R): Attach handle using screws and washers.

Assembling the carriage (TDS 120 R): Attach carriage construction (wheels, bar handle, feet). Mount feet and axle using screws, secure axle with split pins. Attach wheels to axle ends with nuts and washers. Mount transport handle to feet using screws, washers, and nuts.

Operation

Start-up: Odours may occur initially. Observe minimum distances from walls/objects (Technical Annex).

General Operation: Avoid open doors and windows.

Control Panel:

Before Restarting: Check power cable condition. Set device upright and stable. Avoid tripping hazards with cables. Ensure extension cables are unrolled. Ensure no obstructions to airflow. Keep away from moisture/water.

Connecting the Power Cable: Insert mains plug into a fused socket. Guide cable along the back of the device.

Switching the device on: Set selection switch (20) to desired heating level.

Setting the room thermostat: Select desired temperature using rotary switch (19). The thermostat automatically controls room temperature, switching heating off when set value is exceeded and the fan continues to cool down the heater.

Shutdown: Switch off using selection switch (20) to position 0. Fan runs for approx. 3 minutes for rundown operation. Wait for fan to stop, then unplug by holding the plug. Allow to cool down. Clean and store.

Errors and Faults

Warning: Opening the device requires authorized specialists.

Troubleshooting:

Note: Wait at least 3 minutes after maintenance/repair before switching on.

Persistent Issues: Contact customer service or an authorized specialist/Trotec for repair.

Maintenance

Maintenance Intervals:

Maintenance and Care IntervalBefore every start-upAs neededAt least every 2 weeksAt least every 4 weeksAt least every 6 monthsAt least annually
Check air inlets and outlets for dirt and foreign objects and clean if necessaryX
Check air inlet grid(s) for dirt and foreign objects and clean if necessaryXX
Clean the exteriorXXX
Visually check the inside of the device for dirtXXX
Check for damageX
Check attachment screwsX
Test runX

Maintenance and Care Log: A table is provided to record maintenance activities, dates, and signatures for up to 16 entries.

Technical Annex

Activities required before starting maintenance: Warnings regarding electrical voltage and opening the device apply.

Cleaning the housing: Use a soft, damp, lint-free cloth. Protect electrical components from moisture. Do not use aggressive cleaning agents. Wipe dry.

Technical Data:

ParameterTDS 75 RTDS 120 R
ModelTDS 75 RTDS 120 R
Heating capacity level 1Ventilation onlyVentilation only
Heating capacity level 25000 W15000 W
Heating capacity level 310000 W30000 W
Heating capacity level 415000 W
Air flow rate1100 m³/h1900 m³/h
Operating range-20 °C to +45 °C-20 °C to +45 °C
Mains connection400 V / 50 Hz400 V / 50 Hz
Power consumption max.15000 W30000 W
Nominal current consumption21.7 A43.3 A
Fusing32 A63 A
Plug typeCEE 32 A, 5-pinCEE 63 A, 5-pin
Type of protectionIPX4IPX4
Sound pressure level (at a distance of 1 m)57 dB(A)61 dB(A)
Weight19 kg32.5 kg
Dimensions (length x width x height)495 x 350 x 520 (mm)860 x 565 x 645 (mm)
Minimum distance to walls and other objectstop (A): 50 cm
rear (B): 50 cm
sides (C): 50 cm
front (D): 50 cm
top (A): 50 cm
rear (B): 50 cm
sides (C): 50 cm
front (D): 50 cm

Circuit Diagrams

Circuit diagram TDS 75 R: Illustrates the electrical connections including thermostat, switch, motor, time-delay thermostat, self-resetting thermostat, and heating element.

Circuit diagram TDS 120 R: Illustrates the electrical connections including thermostat, switch, motor, time-delay thermostat, self-resetting thermostat, contractors, and heating element.

Spare Parts

Overview of spare parts TDS 75 R: Diagram showing numbered components. A list provides part numbers, specifications, and quantity.

Overview of spare parts TDS 120 R: Diagram showing numbered components. A list provides part numbers, specifications, and quantity.

(Detailed spare parts lists are extensive and are available in the original document.)

Disposal

The crossed-out waste bin icon ?️ indicates that this equipment must not be disposed of with household waste. Find collection points for free return of waste electrical and electronic equipment. Addresses can be obtained from your municipality or local administration. More information on return options for EU countries is available at https://hub.trotec.com/?id=45090. Separate collection enables re-use, recycling, and recovery, preventing negative environmental and health effects.

Declaration of Conformity

Declaration of conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II, Part 1, Section A.

Manufacturer: Trotec GmbH, Grebbener Straße 7, D-52525 Heinsberg.

Product Model: TDS 75 R, TDS 120 R.

Product Type: Electric heater.

Year of manufacture: 2021.

Relevant EU directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2015/863/EU.

Applied harmonised standards: EN 55014-1:2017, EN 60335 series, EN 61000 series.

Place and date of issue: Heinsberg, 11.08.2021.

Issued by: Detlef von der Lieck, Managing Director.

Models: TDS 75 R, Electric Fan Heater, Fan Heater, Heater

File Info : application/pdf, 17 Pages, 1.94MB

PDF preview unavailable. Download the PDF instead.

TRT-BA-TDS-75R-TDS-120R-TC-007-EN

References

SCHEMA ST4 ST4 PDF Engine (Build 10.0.2.0)

Related Documents

Preview TROTEC TDS 30 M / TDS 50 M Ceramic Heaters User Manual and Technical Specifications
Comprehensive user manual and technical data for TROTEC TDS 30 M and TDS 50 M ceramic space heaters, covering safety, operation, maintenance, and troubleshooting.
Preview TROTEC TFC 18 E Fan Heater Operating Manual - Safety, Operation, Maintenance
Comprehensive operating manual for the TROTEC TFC 18 E fan heater. Learn about safety instructions, intended use, operation, maintenance, technical specifications, and troubleshooting for your ceramic heater.
Preview TROTEC TFH 20 E / TFH 22 E Fan Heater User Manual
This manual provides instructions for the TROTEC TFH 20 E and TFH 22 E fan heaters, covering safety, operation, maintenance, and technical specifications. Learn how to safely and effectively use your fan heater for comfortable heating.
Preview TROTEC TEH 20 T / TEH 30 T Electric Heater: Original Instructions
Comprehensive original instructions for the TROTEC TEH 20 T and TEH 30 T electric heaters, covering safety, operation, maintenance, and technical specifications.
Preview TROTEC TCH 1 E Convector Heater: Operating Manual
Comprehensive operating manual for the TROTEC TCH 1 E convector heater, detailing safety instructions, assembly, operation, maintenance, and technical specifications.
Preview Trotec TFC 16 E Fan Heater Operating Manual
This operating manual provides comprehensive instructions for the Trotec TFC 16 E fan heater, covering safety, operation, maintenance, and technical specifications. It is designed for well-insulated spaces and occasional use.
Preview TROTEC TRH Series Oil-Filled Radiators: Instructions, Safety, and Technical Data
Comprehensive instructions, safety guidelines, technical specifications, and troubleshooting for TROTEC TRH 20 E, TRH 21 E, TRH 22 E, TRH 23 E, and TRH 24 E oil-filled radiators. Learn how to safely operate, maintain, and install your TROTEC heater.
Preview TROTEC TCH 2010 E / TCH 2011 E Designer Glass Convector Operating Manual
Comprehensive operating manual for the TROTEC TCH 2010 E and TCH 2011 E Designer Glass Convectors, covering safety, operation, maintenance, and technical specifications.