Trane S8V2 Series Gas-Fired Furnaces with Variable Speed Motor
Product Data
Link Communicating or 24 Volt Gas-Fired 2 Stage Induced Draft Furnaces with Variable Speed Motor
Upflow, Downflow, Horizontal Right/Left
Two Stage
Model Numbers:
- S8V2A040M3PC/D
- S8V2B060M4PC/D
- S8V2B080M4PC/D
- S8V2C080M5PC/D
- S8V2C100M5PC/D
- S8V2D120M5PC/D
Note: Models with "D" in the 12th digit meet California's emissions requirements of less than 40 ng/J (NOx).
Note: Graphics are for representation only. Actual models may differ in appearance.
General Features
COMMUNICATING MODE: Furnace is shipped ready for connection in communicating mode. Requires A/T LINK360A2VVUA Link Smart Thermostat and System Controller (ordered separately).
COMFORT CONTROL: Link communicating technology seamlessly connects system components for advanced diagnostics, performance updates, and optional remote monitoring.
ALTERNATE 24V MODE: Field configurable to 24V non-communicating mode.
NATURAL GAS MODELS: Certified by Intertek for natural and L.P. gas. Limit setting and rating data approved under ANSI standards.
SAFE OPERATION: Integrated System Control (ISC) is a solid-state device monitoring flame presence. Dual solenoid combination gas valve and regulator provide additional safety.
QUICK HEATING: Durable, cycle-tested, heavy gauge aluminized steel heat exchanger for efficient heat transfer. Low energy power vent blower for increased efficiency and fume discharge.
BURNERS: Multiport, Inshot burners for quiet and efficient service. All models convertible to L.P. gas with a conversion kit.
INTEGRATED SYSTEM CONTROL: Operational program controls furnace limit sensors, blowers, gas valve, and flame control with self-diagnostics.
ENERGY EFFICIENT OPERATION: Air-Tite™ cabinet design certified to <1% air leakage per ASHRAE 193.
AIR DELIVERY: Efficient, variable speed blower motor delivers consistent airflow, adjusting for heating or cooling demands.
STYLING: Heavy gauge steel, wrap-around cabinet with baked-on enamel finish. Multiple venting options available.
FEATURES AND GENERAL OPERATION: Silicon Nitride Hot Surface Ignition system eliminates constant pilot. Integrated system control lights main burners upon demand. Complete front service access. Features include low energy power venter and vent proving pressure switches.
Features and Benefits
- LINK COMMUNICATION OR 24 VOLT CONTROL: Seamless connection for performance monitoring and diagnostics via Mobile App. Field configurable to 24V non-communicating mode.
- 80% AFUE: Lowers utility bills.
- ELECTRICALLY EFFICIENT: Efficient airflow design reduces electrical energy use.
- 34 INCH TALL: Lighter, easier to move and fit into tight spaces. Works with larger, high-efficiency coils.
- No knockouts.
- 4-WAY MULTI-POISE: 12 SKUs (Upflow, Downflow, Horizontal Left/Right) for added flexibility and reduced specification errors.
- AIRFLOW: At least 400 CFM/ton at 0.5 in. H2O external static pressure.
- REGULATORY: All models are air tight (≤1% air leakage per ASHRAE 193). Open vestibule design for ease of installation and service.
- DIMENSIONS: Industry standard widths (14.5", 17.5", 21", 24.5"), approximately 28" depth. Cabinet compatible with industry standard coils and accessories.
- INTEGRATED FURNACE CONTROL: Features include Setup/Status/Diagnostics/Digital Display, no dip switches, last six errors stored, dry contact EAC and HUM connections, all Molex connections, and a rain shield over the IFC.
- TUBULAR ALUMINIZED STEEL HEAT EXCHANGER.
- VORTICA II BLOWER: Designed exclusively for S-Series furnaces for improved airflow efficiency and durability. Easy to clean housing. Single piece belly band/motor arm assembly. Blower deck with full-length rails for easy removal.
- FOUR-WAY MULTI-POISE: Easier to specify, shipped ready to install, with at least two venting options per model.
Accessories
Table 1. Accessories
Model Number | Description | Use with |
---|---|---|
BAYHANG | Horizontal Hanging Kit | All Furnaces |
BAYSENSC360 | Supply Air Temperature Sensor | All Furnaces |
BAYFURNPTKT | Return Air Static Pressure Sensor | All Furnaces |
BAYLIFTB | Dual Return Kit (B size extension) | B Cabinet Furnaces |
BAYLIFTC | Dual Return Kit (C size extension) | C Cabinet Furnaces |
BAYLIFTD | Dual Return Kit (D size extension) | D Cabinet Furnaces |
BAYBASE205 | Downflow Subbase | All Furnaces in Downflow orientation |
BAYSF1165AA (a) | 1" SlimFit Box with MERV 4 Filter | All Furnaces |
BAYSF1255BA | 1" SlimFit Filter and Insulated Frame | All furnaces when used in side return application; B Cabinet furnaces only when in bottom return application |
FLRSF1255 | 1" Filter replacement (Qty 12) | B, C, and D Furnaces in Downflow orientation |
BAYVENT600A | Internal venting kit | All furnaces |
BAYVENT800B | Masonry Chimney Vent Kit | All furnaces |
BAYSWT22AHALTAA | High Altitude Pressure Switch Kit | S8V2A040M3P* |
BAYSWT16AHALTAB | High Altitude Pressure Switch Kit | S8V2C080M5P* |
BAYSWT18AHALTAA | High Altitude Pressure Switch Kit | S8V2B080M4P* |
BAYSWT19AHALTAA | High Altitude Pressure Switch Kit | S8V2C100M5P* |
BAYSWT23AHALTAA | High Altitude Pressure Switch Kit | S8V2B060M4P* |
BAYSWT24AHALTAA | High Altitude Pressure Switch Kit | S8V2D120M5P* |
BAYLPSS400* | Propane Conversion Kit with Stainless Steel Burners | All Furnaces |
PIP02095 | U fitting for gas piping | All Furnaces for right hand gas entry |
* Denotes latest revision.
(a) Airflow greater than 1600 CFM requires dual returns.
Product Specification
Tables detailing specifications for various S8V2 models are provided, including:
- Ratings (BTUH Input/Capacity, Temp. Rise, AFUE, Return Air Temp.)
- Blower Drive specifications (Diameter, Speeds, Motor HP, RPM, Volts, FLA)
- Combustion Fan specifications
- Heat Exchanger type and gauge
- Orifices (Natural Gas and L.P. Gas)
- Gas Valve and Pilot Safety Device type
- Burner Quantity
- Power Connection details
- Dimensions (Uncrated and Crated)
- Weight (Shipping/Net)
Specific values vary by model and are presented in detailed tables across pages 6 through 16.
Airflow Tables
Detailed airflow tables are provided for heating and cooling performance, showing CFM, Temp. Rise (°F), and Power (Watts) versus External Static Pressure for various models and tonnage ratings. These tables are presented across pages 8 through 16.
Wiring Diagrams
Wiring diagrams are provided, illustrating the connections for various components including the Integrated Furnace Control (IFC), thermostat, blower motor, gas valve, and sensors. Color codes for wires and terminal designations are included.
Key Information from Wiring Diagrams:
- Wire color codes: BK (Black), BL (Blue), BR (Brown), GR (Green), GY (Gray), OR (Orange), RD (Red), WH (White), YL (Yellow).
- Error Codes and Status Codes are listed for diagnostic purposes.
- LED Flash Rates indicate system status (Idle, 24V Mode, Active Demand, Error).
- Model Number Recovery information is provided.
- Notes on wiring include temperature ratings for wires, use of Y1/Y2 for airflow, jumper settings for single-stage thermostats and heat pumps, and flame current specifications.
- Electrical ratings for the IFC are detailed.
- Timing parameters for furnace operation are listed (e.g., Pre-purge, Inter-purge, Post-purge, Igniter Warm-up).
- CAN connectors are used for Link communicating mode.
Electrical Connections
24V Field Wiring: Diagrams illustrate field wiring for two-stage heating thermostats, one/two-stage AC, and heat pump systems. Notes provide guidance on HP wiring, thermostat connections, and jumper usage.
Mount Supply Air Temperature Sensor: Instructions on mounting the Supply Air Sensor (BAYSENSC360) are provided, including optimal placement and configuration within the Diagnostic App.
External Switches and Accessories: Guidance on connecting humidifiers, electronic air cleaners, and external switches (like smoke detectors) using ACC1 and ACC2 terminals. Notes on configuration in Link Communicating mode and 24V mode are included.
Low Voltage Maximum Wire Length: Tables specify maximum wire lengths for communicating and 24-volt control wires (18 AWG).
Link Communicating Low Voltage Wire Connectors: Information on using color-coded connectors for easy installation in Link mode. Instructions for stripping wires and seating them in connectors are provided.
Link Communicating Low Voltage Hook-Up Diagrams: Diagrams show typical hook-up configurations for communicating outdoor units, indoor units, distribution boards, user interfaces, and system controllers.
Outline Drawing
Dimensional drawings of the furnace cabinets are provided, showing various sizes (A, B, C, D) and their corresponding dimensions. Details include flue outlets, gas supply connections, and electrical/thermostat wire entry points.