Trane A801X060BM4SC Single Stage Gas Furnace
Product Overview
This submittal document details the Upflow / Downflow / Horizontal Left/Right Single Stage Non-condensing Gas Fired Furnace with a capacity of 60,000 BTUH. The model number is A801X060BM4SC.
Note: Models may feature a "T" in the 12th digit to indicate compliance with California's less than 40 ng/J (NOx) emissions requirements.
Note: Graphics provided are for representation only; actual models may vary in appearance.
Document Date: March 2023
Outline Drawing and Cabinet Dimensions
The outline drawing illustrates the 17.5" width cabinet, showing various dimensions and connection points. Key dimensions include:
- Cabinet Width: 17.5 inches
- Approximate Depth: 28 inches
- Height: 34 inches
- Flue Outlet Diameter: Ø5 inches
- Gas Supply Connection: Ø7/8 inches
- Electrical Wires Connection: Ø7/8 inches
- Thermostat Wires Connection: Ø7/8 inches
- Side return air dimensions are also detailed.
The drawing supports Upflow, Downflow, and Horizontal Left/Right installation configurations.
Product Specifications
MODEL | A801X060BM4SC (a) | MODEL | A801X060BM4SC (a) |
Type | Upflow / Horizontal / Downflow | VENT PIPE DIAMETER - Min. (in.) (e) | 4 Round |
RATINGS (b) | HEAT EXCHANGER - Type | Aluminized Steel | |
Input BTUH | 60,000 | Gauge (Fired) | 20 - 19 |
Capacity BTUH (ICS) (c) | 48,700 | ORIFICES - Main | |
Temp. Rise (Min. - Max.) °F | 30 - 60 | Nat. Gas Qty. - Drill Size | 3 - 45 |
AFUE - Rating (c) | 80 | L.P. Gas Qty. - Drill Size | 3 - 56 |
Return Air Temp. (Min. - Max.) °F | 55°F - 80°F | GAS VALVE | Redundant - Single Stage |
BLOWER DRIVE | DIRECT | PILOT SAFETY DEVICE - Type | 120 V SiNi Igniter |
Diameter - Width (in.) | 11 X 8 | BURNERS - QTY | 3 |
No. Used | 1 | POWER CONN. - V/Ph/HZ (f) | 120 / 1 / 60 |
Speeds (No.) (d) | CTM - 9 | Ampacity (Amps) | 12.0 |
CFM vs. in. w.g. | See Fan Performance Table | Max. Overcurrent Protection (Amps) | 15 |
Motor HP | 3/4 | PIPE CONN. SIZE (IN.) | 1/2 |
R.P.M. | 1050 | DIMENSIONS | HxWxD |
Volts / Ph / Hz | 120 / 1 / 60 | Uncrated (in.) | 34 x 17.5 x 28.75 |
FLA | 9.2 | Crated (in.) | 35.5 x 19.5 x 30.87 |
COMBUSTION FAN - Type | PSC | WEIGHT | |
Drive - No. Speeds | Direct - 1 | Shipping (Lbs.)/Net (Lbs.) | 132 / 124 |
Motor RPM | 3300 | ||
Volts/Ph/Hz | 120 / 1 / 60 | ||
FLA | 0.30 | ||
Inducer Orifice | 1.40 | ||
FILTER - Furnished? | No | ||
Type Recommended | High Velocity | ||
Hi Vel. (No.-Size-Thk.) | 1 - 16 X 25 - 1 in. |
(a) Central Furnace heating designs are certified to ANSI Z21.47 - latest edition.
(b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 10,000 feet for elevations above 2,000 feet above sea level.
(c) Based on U.S. government standard tests.
(d) 9 Speed constant torque ECM Blower Motor.
(e) Refer to the Installer's Guide.
(f) The above wiring specifications are in accordance with National Electric Code; however, installations must comply with local codes.
Airflow Table
Furnace Airflow (CFM) vs. External Static Pressure (in. W.C.)
Model | Tap | Static | |||||
0.1 | 0.3 | 0.5 | 0.7 | 0.9 | |||
A801X060BM4SC | SCFM | 1 | 596 | 287 | |||
Watts | 38 | 42 | |||||
SCFM | 2 | 851 | 667 | 483 | 299 | 115 | |
Watts | 70 | 81 | 92 | 102 | 113 | ||
SCFM | 3 | 1142 | 1018 | 893 | 769 | 644 | |
Watts | 141 | 156 | 172 | 187 | 203 | ||
SCFM | 4 | 1196 | 1079 | 961 | 844 | 726 | |
Watts | 160 | 176 | 192 | 208 | 224 | ||
SCFM | 5 | 1362 | 1258 | 1154 | 1050 | 946 | |
Watts | 220 | 239 | 257 | 276 | 294 | ||
SCFM | 6 | 1416 | 1319 | 1221 | 1124 | 1026 | |
Watts | 250 | 269 | 288 | 307 | 327 | ||
SCFM | 7 | 1495 | 1402 | 1309 | 1216 | 1123 | |
Watts | 287 | 307 | 327 | 347 | 367 | ||
SCFM | 8 | 1574 | 1487 | 1401 | 1314 | 1228 | |
Watts | 337 | 357 | 378 | 399 | 420 | ||
SCFM | 9 | 1983 | 1899 | 1815 | 1730 | 1646 | |
Watts | 659 | 670 | 680 | 691 | 701 |
CFM Versus Temperature Rise
Model | CFM Versus Temperature Rise | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
400 | 500 | 600 | 700 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 1600 | 1700 | 1800 | 1900 | 2000 | 2100 | 2200 | 2300 | 2400 | |
A801X060BM4SC | 56 | 49 | 44 | 40 | 37 | 34 | 32 |
General Features
Natural Gas Models
Furnace designs are certified by Intertek for natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
Safe Operation
The Integrated System Control is a solid-state device that continuously monitors for flame presence during heating operation. A dual solenoid combination gas valve and regulator provide additional safety.
Quick Heating
Features a durable, cycle-tested, heavy gauge tubular aluminized steel heat exchanger for quick heat transfer to provide warm conditioned air. A low energy power vent blower increases efficiency and discharges gas fumes externally.
Burners
Multiport, Inshot burners are designed for quiet and efficient service. All models can be converted to L.P. gas using an LP conversion kit.
Integrated System Control
An exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, and flame control, including self-diagnostics for ease of service.
Energy Efficient Operation
The Air-Tite™ cabinet design is certified to <1.4% air leakage per ASHRAE 193 “Method of Test for Determining the Airtightness of HVAC Equipment.”
Air Delivery
The 9-speed constant torque blower motor delivers sufficient airflow for most heating and cooling requirements, switching speeds based on room thermostat demand.
Styling
Constructed with heavy gauge steel and "wrap-around" cabinet design for strength. Each orientation offers at least two venting options. The cabinet has no knockouts.
Features and General Operation
The furnace utilizes a Silicon Nitride Hot Surface Ignition system, eliminating the need for a constant burning pilot. The integrated system control ignites the main burners upon a heat demand from the room thermostat. It offers complete front service access, a low energy power venter, and vent proving pressure switches.
Features and Benefits
- 80% AFUE: Contributes to lower utility bills.
- Electrically Efficient: Efficient airflow design reduces electrical energy consumption.
- 34 Inch Tall: Lighter and easier to move, fitting into tight spaces like short basements or closets.
- Compatibility: Works effectively with larger, high-efficiency coils.
- No Knockouts: Simplifies installation procedures.
- 4-Way Multi-Poise: Available in 8 SKUs, supporting Upflow, Downflow, Horizontal Left, and Horizontal Right configurations, enhancing application flexibility and reducing specification errors.
- Airflow: Achieves at least 400 CFM/ton at 0.5 in. H2O external static pressure.
- Regulatory Compliance: Models are air tight, with 1.4% or less air leakage as per ASHRAE 193. Features an open vestibule design for easier installation and service.
- Dimensions: Industry standard width of 17.5"; depth is approximately 28". Cabinet is compatible with industry standard coils and other accessories.
- Integrated Furnace Control: Provides Setup / Status / Diagnostics / Digital Display. Features no dip switches, stores the last six errors, uses all Molex connections (no spade terminals), has labeled low voltage connections, and includes a rain shield over the IFC to protect the control from condensate.
- Tubular Aluminized Steel Heat Exchanger: Ensures durability and efficient heat transfer.
- 9 Speed Constant Torque Blower Motor: Offers a greater range of operation and higher efficiency compared to standard PSC blower motors. Taps are electronically selectable at the IFC.
- Four-Way Multi-Poise Design: Simplifies specification and is shipped ready for installation (no conversion kits required). Every model includes at least two venting options.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard are dedicated to creating comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.
The manufacturer maintains a policy of continuous data improvement and reserves the right to change designs and specifications without prior notice. They are committed to using environmentally conscious print practices.
Certifications: ETL US Listed by Intertek.
Document Version: A801X060BM4-SUB-3B-EN (March 2023). Supersedes A801X060BM4-SUB-3A-EN (July 2021).