Victron Energy Isolation Transformers
Only in Dutch warehouse / see product numbers in table
Safety and prevention of galvanic corrosion
The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms.
Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion. Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.
Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc.
It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply.
It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.
The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply.
The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer, and the ship is connected to the secondary.
The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip, or a fuse will blow in case of a short circuit.
Soft start is a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur.
It is also recommended, for optimal safety, to connect the secondary neutral of the transformer to ground when the boat is out of the water.
Product Specifications
2000 Watt (1) | 2500 Watt (1) | 3600 Watt (1) | 3600 Watt Auto (1) | 7000 Watt | |
---|---|---|---|---|---|
Product number | ITR040252042 | ITR040362042 | ITR050362042 | ITR000702002 | |
Input | 115/120 or 230/240 V | 115/120 or 230/240 V | 115/120 or 230/240 V | Automatic 115/120 or 230/240 V switching | 230/240 V |
Output | 115/120 or 230/240 V | 115/120 or 230/240 V | 115/120 or 230/240 V | 115/120 or 230/240 V | 230/240 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Rating | 17/8,5 A | 22/11 A | 32/16 A | 32/16 A | 32 A |
Soft start | Yes | Yes | Yes | Yes | Yes |
Transformer type | Toroidal (low noise, low weight) | ||||
Input circuit breaker | ENCLOSURE | ||||
Material | Aluminium (blue RAL 5012) | ||||
Protection category | IP 21 | ||||
Weight | 12,7 kg | 22,2 kg | 22,2 kg | 27,5 kg | |
Dimensions (hxwxd) mm | 375 x 214 x 135 | 446 x 214 x 135 | 362 x 258 x 221 | 362 x 258 x 243 |
STANDARDS
EN 60076
Safety
(1) Can be used as:
- 115 V to 115 V isolation transformer
- 115 V to 230 V isolation transformer
- 230 V to 115 V isolation transformer
- 230 V to 230 V isolation transformer
Diagrams
Shore ground connected to immersed metals of the boat causes galvanic corrosion
A diagram shows shore power connected to a boat's ground, leading to galvanic current flowing between the shore ground and the boat's immersed metals, causing corrosion.
Shore ground isolated from boat ground
A diagram illustrates an Isolation Transformer placed between the shore power and the boat. The shore ground is connected to the primary side of the transformer, while the boat's ground is connected to the secondary side. This setup isolates the boat from shore ground, preventing galvanic current flow.
Internal wiring diagram
The internal wiring diagram shows the primary and secondary windings of a toroidal transformer, with connections for Line (L), Neutral (N), and Protective Earth (PE) on both the shore and ship sides. A soft start component is indicated in series with the primary winding.