Galvanic Isolator VDI-16, VDI-32, VDI-64 Installation Manual
1. Mounting Location
⚠ Warning!
For safety purposes, the product should be installed in a heat-resistant environment. Avoid the presence of e.g. chemicals, synthetic components, curtains or other textiles in the immediate vicinity of the product.
1.1. Installation Area: Install the galvanic isolator in a well ventilated area.
1.2. Ventilation Clearance: Keep a clear space of 10 cm around the product for ventilation.
1.3. Mounting Orientation: The galvanic isolator must be mounted with its length vertical to allow for maximum cooling. Under normal circumstances, the temperature increase of the heat sink is not more than 20°C. However, the unit may become hot when conducting fault ground current.
2. Installation
⚠ Warning!
The galvanic isolator must be wired into the green (safety) grounding conducting connection ahead of all grounding connections to the vessel such that no ground connections on the vessel bypass the galvanic isolator making it ineffective.
2.1. Regulations: Connections and safety features must be according to the locally applicable regulations.
2.2. Cable Size: Use electric cables of the appropriate size.
2.3. Wiring: Wire the galvanic Isolator into the green (safety) grounding conducting connection as shown in Figure 1.
Figure 1: Wiring Diagram
The diagram illustrates an AC distribution system with 230 Vac, Neutral (N), and Protective Earth (PE) connections. These lead to a Galvanic Isolator, which is then connected to a Boardnet and an RCD (Residual Current Device).
Model | VDI-16 | VDI-32 | VDI-64 |
---|---|---|---|
Galvanic Isolator | Waterproof (potted) | Waterproof (potted) | Waterproof (potted) |
Maximum Current | 16 A | 32 A | 64 A |
Peak Current (20 ms) | 1600 A | 3200 A | 6000 A |
Connection | M6 | M6 | M6 |
Heat Sink Material | Anodized aluminium | ||
Protection Category | IP 67 | ||
Weight | 1 kg | 2 kg | 3,2 kg |
Dimensions (h x w x d) | 60 x 120 x 200 mm | 63 x 164 x 200 mm | 63 x 164 x 335 mm |