Komfovent Domekt R 450 V C6M Air Handling Unit
Technical specifications and performance data for the Domekt R 450 V C6M air handling unit with a rotary heat exchanger.
Product Specifications
Maximum airflow, m³/h | 496 |
Maximum airflow, l/s | 138 |
Reference airflow, m³/s | 0.096 |
Reference pressure drop, Pa | 50 |
SPI, W/(m³/h) | 0.3 |
Temperature efficiency for heat recovery, % | 86 |
Electric post-heater power, kW / At, °C | 1/8.5 |
Supply voltage, V | ~230 |
Max. operating current HE, A | 7.5 |
Power supply cable, mm² | 3x1.5 |
Fan power at maximum airflow, W | 147 |
Fan power at reference airflow, W | 55 |
Sound power level, LWA, dB(A) | 38 |
Sound pressure level, LpA, dB(A) (3 m) | 28 |
Filter dimensions B×H×L, mm | 517×278×46 |
Supply air filter | ePM1 60 (F7) |
Extract air filter | ePM10 50 (M5) |
Unit dimensions B×H×L, mm | 585×655×680 |
Service space, mm | 700 |
Unit weight, kg | 60 |
Performance Data
The performance curves illustrate the relationship between static pressure and airflow for different SPI values.
The graph shows airflow in l/s on the x-axis and static pressure in Pa on the y-axis. Several curves are plotted, labeled SPI 0.3, SPI 0.4, SPI 0.5, and SPI 0.6, indicating different specific fan power levels.
Temperature Efficiency
Outdoor air temperature, °C | -23 | -15 | -10 | -5 | 0 | 25 | 30 | 35 |
---|---|---|---|---|---|---|---|---|
After heat exchanger, °C | 15.7 | 16.8 | 17.5 | 18.2 | 18.9 | 22.4 | 23.1 | 23.8 |
Indoor +22 °C, 20% RH |
Dimensions
The unit has a compact design with specific connection points for air intake, extract, supply, and exhaust.
Diagram showing the unit with circular air connections labeled ODA (Outdoor Air), EHA (Extract Air), SUP (Supply Air), and ETA (Exhaust Air). The connections are indicated with diameters and positions on the unit's right side.
Diagram showing the unit with circular air connections labeled ODA (Outdoor Air), EHA (Extract Air), SUP (Supply Air), and ETA (Exhaust Air). The connections are indicated with diameters and positions on the unit's left side.
Accessories
Accessory | Model |
---|---|
Shut-off damper | AGUJ-M-160+TF230/CM230 |
Silencer | ODA/EHA ASTS-160-600-M |
Silencer | SUP/ETA ASTS-160-900-M |
Heating coil | DH-160 |
Shunt group | PPU-HW-3R-15-0,4-W2 |
2-way valve (heating coil) | VVP47.10-0,4+SSF161.05HF |
Cooling coil | DCW-0,5-3 |
2-way valve (cooling coil) | VVP47.10-1,6+SSF161.05HF |
Combi-hood | LD-160 |
Air heater/cooler | DHCW-160 |
DX-cooler | DCF-0,5-3 |
Refrigeration unit | MOU-12HFN8a+ KA8142 |
Energy Efficiency Labels
The unit complies with energy efficiency standards, as indicated by the labels present.
The unit features energy efficiency labels, including an A+ rating, indicating high energy performance.
Control Options
The unit can be controlled via various interfaces, including smart controls.
Visuals show different control units, labeled C6.1 and C6.2, suggesting options for managing the air handling unit's functions.