Overview
The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them.
Instrument Set-up
Display
The device display shows:
- Area/Volume
- Pythagoras
- Battery Indicator (?)
- Measuring Reference
- Current Measurement Value
- Units
The device has the following buttons:
- On/Off/Measure/Continuous measuring button
- Area/Volume/Pythagoras button
- Units button
Insert Batteries
Follow these steps to insert batteries:
- Open the battery compartment cover.
- Insert two AAA batteries, observing correct polarity (+/-).
- Close the battery compartment cover.
ℹ️ Change batteries when the battery symbol is empty.
Operations
Switching ON/OFF
Press the [Laser On Button] for 5 seconds to turn the device ON.
Press the [Laser On Button] for 5 seconds to turn the device OFF.
The device switches off automatically after 120 seconds of inactivity.
If the info icon (ℹ️) appears with a number, refer to the "Message Codes" section for instructions. Example: 204.
Unit Setting
Press and hold the [Units Button] for 3 seconds to switch between the following units:
- 0'00" 1/16
- 0.000 m
- 0.00 ft
- 0 1/16 in
Measurement Reference
The system default measurements start from the bottom of the device as the reference point.
To change the reference point:
- Press the [Units Button] to change the reference to the extension bar point for measurement.
- Press the [Units Button] again to change the reference to the top of the device for measurement.
Functions
Measuring Single Distance
1. Aim the active laser at the target.
2. Press the [Laser On Button].
3. The measured distance (e.g., 39'99" 7/16) is displayed.
Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam, or semi-permeable surfaces, or when aiming at high gloss surfaces. Against dark surfaces, the measuring time increases.
Continuous Measuring
1. Press and hold the [Laser On Button] for 3 seconds.
2. Aim the active laser at the target.
3. The last value measured is continuously displayed.
4. Press the [Laser On Button] to stop continuous measuring.
Area Measurement
1. Press the [Area/Volume/Pythagoras Button] once (1x).
2. Aim the laser at the first target point.
3. Aim the laser at the second target point.
4. The result (e.g., 29.99 ft²) is shown in the main line and the measured distance above.
Volume Measurement
1. Press the [Area/Volume/Pythagoras Button] twice (2x).
2. Aim the laser at the first target point.
3. Aim the laser at the second target point.
4. Aim the laser at the third target point.
5. The result (e.g., 29.99 ft³) is shown in the main line and the measured distance above.
Pythagoras (2-point)
1. Press the [Area/Volume/Pythagoras Button] three times (3x).
2. Aim the laser at the first target point.
3. Aim the laser at the second target point.
4. The result (e.g., 39'99" 7/16) is shown in the main line and the measured distance above.
Pythagoras (3-point)
1. Press the [Area/Volume/Pythagoras Button] four times (4x).
2. Aim the laser at the first target point.
3. Aim the laser at the second target point (perpendicular to the measuring surface).
4. Aim the laser at the third target point.
5. The result (e.g., 39'99" 7/16) is shown in the main line and the measured distance above.
Technical Data
General
Parameter | Value |
---|---|
Maximum measuring range* | 1.14-135ft / 0.35-40m (measure from top side) |
Measuring accuracy* | ± 1/8 in / ± 3 mm |
Measuring units | ft+inch/m/ft/inch |
Laser class | 2 |
Laser type | 620nm - 690nm |
Autom. power switch-off | 120s |
Autom. laser off | 30s |
Battery durability (2 x AAA) | Up to 3000 measurements |
Dimension (LxWxH) | 4.02 x 1.42x0.75 in / 102 x 36 x19 mm |
Weight (without batteries) | 1.76oz / 50g |
Operation Temperature | 32 to 104 °F / 0 to 40 °C |
Storage Temperature | 14 to 140 °F / -10 to 60 °C |
* The typical measurement uncertainty of ± 3 mm is valid for measurements on white, diffusive, reflective targets up to 5 m at low ambient light and moderate temperatures. For distances greater than 5 m, the measurement uncertainty could increase additionally by 0.1 mm/m. In unfavourable conditions (such as bright sunlight, targets with poor reflectivity, or high or low temperatures) the measurement uncertainty could further increase up to ± 8 mm for distances below 5 m and additionally by roughly 0.15 mm/m for distances greater than 5 m.
Error, Faults & Troubleshooting
Issue | Cause | Action |
---|---|---|
Failure to switch on | Hardware protection after shocking | Restart the device |
Low battery | Recharge the device | |
All dashes shows on display | Insufficient On/Measure/Units button press | Press the On/Measure/Units button firmly |
Beam is moved too fast | Move the measuring tool slowly | |
The object is out of rated range | Measure within rated range | |
Received signal too weak / Measuring time too long | Change target surface (e.g. white paper) | |
Received signal too strong (target is too reflective) | Change target surface (e.g. white paper) | |
Ambient light is too strong | Shadow target area |
Care
- Clean the device with a damp, soft cloth.
- Never immerse the device in water.
- Never use aggressive cleaning agents or solvents.
Disposal
CAUTION: The battery must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations. The product must not be disposed of with household waste.
Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the national and country specific regulations. Product specific treatment and waste management can be downloaded from the Prexiso homepage.
Safety Instructions
The person responsible for the instrument must ensure that all users understand these directions and adhere to them.
Symbols Used
The symbols used have the following meanings:
- WARNING: Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury.
- CAUTION: Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.
- ℹ️ Important: Paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.
Permitted Use
- Measuring distances
Prohibited Use
- Using the product without instruction
- Using outside the stated limits
- Deactivation of safety systems and removal of explanatory and hazard labels
- Opening of the equipment by using tools (screwdrivers, etc.)
- Carrying out modification or conversion of the product
- Use of accessories from other manufacturers without express approval
- Deliberate dazzling of third parties; also in the dark
- Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
- Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines which are running or near parts of machines or installations which are unprotected
- Aiming directly in the sun
Hazards in Use
WARNING: Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified. Carry out periodic test measurements, particularly after the instrument has been subject to abnormal use, and before, during, and after important measurements.
CAUTION: Never attempt to repair the product yourself. In case of damage, contact a local dealer.
WARNING: Changes or modifications not expressly approved could void the user's authority to operate the equipment.
Limits of Use
Refer to section "Technical Data". The device is designed for use in areas permanently habitable by humans. Do not use the product in explosion hazardous areas or in aggressive environments.
Areas of Responsibility
Responsibilities of the person in charge of the instrument:
- To understand the safety instructions on the product and the instructions in the User Manual.
- To be familiar with local safety regulations relating to accident prevention.
- Always prevent access to the product by unauthorised personnel.
Electromagnetic Compatibility (EMC)
WARNING: The device conforms to the most stringent requirements of the relevant standards and regulations. However, the possibility of causing interference in other devices cannot be totally excluded.
FCC Statement (applicable in U.S.)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Laser Classification
The device produces visible laser beams, which are emitted from the instrument. It is a Class 2 laser product in accordance with: IEC60825-1: 2014 "Radiation safety of laser products".
Laser Class 2 products: Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses including the blink reflex.
WARNING: Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous.
Warranty
Two-Year Limited Warranty. This product is warranted to the original purchaser from the original purchase date for two years subject to the warranty coverage described herein. Please retain your receipt. This product is warranted to the original user to be free from defects in material and workmanship. If you believe that the product is defective at any time during the specified warranty period, please contact Prexiso customer service by sending an email to info@prexiso-eu.com. This warranty does not cover: (1) Part failure due to normal wear or product abuse; (2) Any parts have been altered or modified by anyone other than authorized Prexiso personnel or failure to install and operate equipment according to the guidelines put forth in the instruction manual; (3) Any products or parts used for rental purposes, damage resulting from shipping (claims must be filed with freighter), accident, abuse, act of God, misuse, or neglect.
Prexiso will replace or repair the defective unit, at its option, subject to verification of the defect. Any implied warranties arising from the sale of a Prexiso product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Prexiso shall not be liable for loss of use of the product or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. This warranty excludes any accessories. This warranty gives you specific legal rights, and you may also have other rights that vary from state.
Labelling
Subject to change (drawings, descriptions and technical data) without prior notice.
Product Model: P40T
Brand: PREXISO
Certifications: CE Mark, GS-ADL
Batteries: 2 x AAA
Laser Information: IEC/EN 60825-1: 2014, <1.0mW @ 620-690nm. Laser radiation. Do not stare into beam. Class 2 Laser product. Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
Manufacturer/Distributor Information: www.prexiso-eu.com, Made in China