Prexiso PLT40LI Rechargeable Laser & Tape Measure

A 2-in-1 device combining a 40-meter laser distance meter and a 5-meter tape measure.

Product Overview

The Prexiso PLT40LI is a versatile, rechargeable 2-in-1 measuring tool featuring a 40-meter laser distance meter and a 5-meter tape measure. It is designed for accurate measurements in various applications.

Key Features:

For detailed safety instructions and operation, please read the User Manual before first use.

Website: www.prexiso-eu.com

Table of Contents

Safety Instructions

General Safety:

Retract tape measures slowly to avoid damage to the blade and mechanism, and to prevent injury. Keep fingers away from edges.

The user manual should be read carefully before the product is used for the first time. The person responsible for the product must ensure all users understand these directions and adhere to them.

This product is intended for use by skilled persons only.

CAUTION: Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure.

WARNING: This is a Class 2 laser product in accordance with IEC 60825-1:2014.

Instrument Set-up

Overview

The safety instructions and user manual must be read and understood by all users before operating the product.

Display

The display shows measurement readings, units, battery status, and icons for measurement modes (Area, Volume, Pythagoras).

Key display elements include:

Battery Charging

Charge the device when the battery symbol is empty. The device uses a Type-C USB port for charging.

[Illustration: Device connected to a Type-C cable, showing charging status.]

Operations

Switching ON/OFF

Press the [ON/Measure] button to turn the device ON. The device will automatically switch OFF after 120 seconds of inactivity to save power.

[Illustration: Device showing ON state with laser active, and OFF state after 5 seconds.]

Measuring Single Distance

  1. Press the [FUNC] button to activate the laser.
  2. Aim the active laser beam at the target surface.
  3. Press the [FUNC] button again to take the measurement. The distance is displayed.

Note on Target Surfaces: Measuring errors can occur with colourless liquids, glass, styrofoam, or semi-permeable surfaces. Aiming at highly reflective surfaces or very dark surfaces may increase measuring time.

[Illustration: Steps for measuring single distance.]

Continuous Measuring

  1. Press and hold the [FUNC] button for 3 seconds to enter continuous measuring mode.
  2. Aim the active laser beam at the target surface and move the device slowly. The distance is continuously updated on the display.
  3. Press the [FUNC] button to stop measuring.

Note on Target Surfaces: Similar to single distance measurement, certain surfaces may cause errors or longer measuring times.

[Illustration: Steps for continuous measuring.]

Advanced Functions

Unit Setting

Press and hold the [UNITS] button for 3 seconds to switch between measurement units. Available units include:

[Illustration: Device showing unit selection.]

Measurement Reference Changing

The device has two measurement reference points:

  1. Default: Measurements are taken from the bottom edge of the device.
  2. Press the [UNITS] button to change the reference to the top edge of the device for measurement.

[Illustration: Device showing measurement reference from bottom and then from top.]

Area Measurement

Calculates the area of a rectangular surface.

  1. Press the [FUNC] button to select Area mode (indicated by '1x').
  2. Aim the laser at the first corner of the area.
  3. Press the [FUNC] button.
  4. Aim the laser at the second corner of the area.
  5. Press the [FUNC] button. The calculated area is displayed (e.g., 39.343 m²).

[Illustration: Steps for area measurement.]

Volume Measurement

Calculates the volume of a rectangular prism.

  1. Press the [FUNC] button to select Volume mode (indicated by '2x').
  2. Aim the laser at the first corner of the volume (e.g., bottom front left).
  3. Press the [FUNC] button.
  4. Aim the laser at the second corner (e.g., bottom front right).
  5. Press the [FUNC] button.
  6. Aim the laser at the third corner (e.g., top front left).
  7. Press the [FUNC] button. The calculated volume is displayed (e.g., 100.182 m³).

[Illustration: Steps for volume measurement.]

Pythagoras (2-point)

Calculates an indirect distance using two measurements and the Pythagorean theorem.

  1. Press the [FUNC] button to select Pythagoras (2-point) mode (indicated by '3x').
  2. Aim the laser at the first target point.
  3. Press the [FUNC] button.
  4. Aim the laser at the second target point, ensuring the laser beam is perpendicular to the measuring surface.
  5. Press the [FUNC] button. The indirect distance is displayed (e.g., 3.907 m).

[Illustration: Steps for 2-point Pythagoras measurement.]

Pythagoras (3-point)

Calculates an indirect distance using three measurements and the Pythagorean theorem.

  1. Press the [FUNC] button to select Pythagoras (3-point) mode (indicated by '4x').
  2. Aim the laser at the first target point.
  3. Press the [FUNC] button.
  4. Aim the laser at the second target point, ensuring the laser beam is perpendicular to the measuring surface.
  5. Press the [FUNC] button.
  6. Aim the laser at the third target point.
  7. Press the [FUNC] button. The indirect distance is displayed (e.g., 7.527 m).

[Illustration: Steps for 3-point Pythagoras measurement.]

Technical Data

General

ParameterValue
Range with favourable conditions *0.35-40m / 1.15-135ft
Accuracy with favourable conditions *±3mm / ±1/8in
Smallest unit displayed1 mm / 1/16in
Laser class2
Laser type620-690 nm, < 1 mW
Power OFF automaticallyafter 120 s
Continuous measuringyes
Dimension (H x D x W)85 x 85 x 43 mm / 3.35 x 3.35 x 1.7 in
Battery durabilityup to 5000 measurements
Weight (with batteries)380 g / 13.4 oz
Temperature range: Storage-10 to 60 °C / 14 to 140 °F
Temperature range: Operation0 to 40 °C / 32 to 104 °F

* The typical measurement uncertainty of ±3 mm is valid for measurements on white, diffusive, reflective targets up to 10m at low ambient light and moderate temperatures. For distances greater than 10 m, the measurement uncertainty could increase additionally by 0.1 mm/m. In unfavourable conditions (such as bright sunlight, targets with poor reflectivity, or high or low temperatures) the measurement uncertainty could further increase up to ±6mm for distances below 10 m.

Troubleshooting

Potential issue table:

IssueCauseAction
Failure to switch onHardware protection after shockingRestart the device
Low batteryRecharge the device
Insufficient On/Measure/Units button pressPress the On/Measure/Units button firmly
Beam is moved too fastMove the measuring tool slowly
The object is out of rated rangeMeasure within rated range
Received signal too weakChange target surface (e.g. white paper)
Measuring time too longChange target surface (e.g. white paper)
Received signal too strong (target is too reflective)Shadow target area
Ambient light is too strongShadow target area
Running program is not in a proper wayRestart in a proper way by the instructions of manual
Hardware problemRestart the device. If not work, contact a local dealer.

Care and Disposal

Care

Disposal

CAUTION: Flat batteries must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations. The product must not be disposed of with household waste.

Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the national and country-specific regulations.

[Illustration: Li-ion battery symbol.]

Warranty

Two-Year Limited Warranty: This product is warranted to the original purchaser from the original purchase date for two years subject to the warranty coverage described herein. Please retain your receipt. This product is warranted to be free from defects in material and workmanship.

If the product is defective during the warranty period, please contact Prexiso customer service by email at info@prexiso-eu.com.

This warranty does not cover:

Prexiso will replace or repair the defective unit at its option, subject to verification of the defect.

Any implied warranties arising from the sale of a Prexiso product are limited to the above. Prexiso shall not be liable for loss of use, incidental or consequential damages, expenses, or economic loss.

This warranty gives you specific legal rights, and you may also have other rights that vary from state.

Detailed Safety Instructions

Symbols Used

The symbols used have the following meanings:

Areas of Responsibility

Responsibilities of the person in charge of the instrument:

Permitted Use

Prohibited Use

Hazards in Use

WARNING: Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified. Carry out periodic test measurements, particularly after the instrument has been subject to abnormal use, and before, during, and after important measurements.

CAUTION: Never attempt to repair the product yourself. In case of damage, contact a local dealer.

WARNING: Changes or modifications not expressly approved could void the user's authority to operate the equipment.

Limits of Use

? Refer to section "Technical Data". The device is designed for use in areas currently habitable by humans. Do not use the product in explosion hazardous areas or in aggressive environments.

Declarations and Classifications

Electromagnetic Compatibility (EMC)

WARNING: The device conforms to the most stringent requirements of the relevant standards and regulations. However, the possibility of causing interference in other devices cannot be totally excluded.

FCC statement (applicable in U.S.)

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Laser Classification

The device produces visible laser beams, which are emitted from the instrument. It is a Class 2 laser product in accordance with:

IEC60825-1 : 2014 "Radiation safety of laser products"

Laser Class 2 products: Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses including the blink reflex.

WARNING: Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous.

CAUTION: Looking into the laser beam may be hazardous to the eyes.

Wavelength: 620 - 690 nm

Pluse duration: > 600ps

Maximum radiant output power for classification: < 1 mW

Pluse repetition frequency: 320 MHZ

Beam divergence: 0.16 mrad x 0.6 mrad

UKCA-DECLARATION OF CONFORMITY

Herewith we, Hangzhou GreatStar Industrial Co., Ltd, 35# Jiuhuan Rd, Jiubao Town, Hangzhou, Zhejiang, China, declare that the following product complies with the appropriate basic safety and health requirements of the UKCA Directives (see item 4) based on its design and type, as brought into circulation by us. This declaration relates exclusively to the product in the state in which it was placed on the market, and excludes components which are added and/or operations carried out subsequently by the final user.

  1. Product: RECHARGEABLE LASER AND TAPE MEASURE
  2. Model No.: PLT40LI
  3. Serial number: N/A
  4. Applicable UKCA Directives: Electromagnetic Compatibility Regulations 2016
  5. Used Harmonized Standards: BS EN 61326-1:2013
  6. Responsible for documentation: (Sea&Mew Accounting Ltd, Electric Avenue Vision 25, London, Enfield EN3 7GD, Billy Han, info@seamew.net)
  7. Additional used UKCA Directives: N/A
  8. Date/place/Name/Authorized signature: 2021-8-19 / Hangzhou / Xu Dong Ling
  9. Title of Signatory: Engineer

[Illustration: Handwritten signature of Xu Dong Ling.]

PDF preview unavailable. Download the PDF instead.

81H4ipoLlUL Adobe PDF library 15.00 Adobe Illustrator CC 22.0 (Windows)

Related Documents

Preview Prexiso PLT40LI Rechargeable Laser & Tape Measure User Manual and Specifications
Comprehensive guide for the Prexiso PLT40LI 2-in-1 rechargeable laser and tape measure, covering setup, operations, safety instructions, technical specifications, troubleshooting, and warranty information.
Preview Prexiso PLT40LI Rechargeable Laser & Tape Measure User Manual
User manual for the Prexiso PLT40LI, a 2-in-1 rechargeable laser distance meter and 16ft tape measure. Covers safety, setup, operations (single distance, continuous, area, volume, Pythagoras), technical data, troubleshooting, care, disposal, and warranty.
Preview Prexiso PLT40LI Rechargeable Laser & Tape Measure User Manual
Comprehensive user manual for the Prexiso PLT40LI, a 2-in-1 rechargeable laser and tape measure. Learn about its features, safety instructions, operations, technical data, and troubleshooting.
Preview PREXISO P30B-3LI Laser Distance Measure User Manual
Comprehensive user manual for the PREXISO P30B-3LI rechargeable pocket laser distance measure, covering safety, setup, operation, measuring functions, technical specifications, troubleshooting, and warranty information.
Preview PREXISO P80E-8L Rechargeable Laser Distance Measure User Manual and Technical Specifications
Official user manual and technical specifications for the PREXISO P80E-8L Rechargeable Laser Distance Measure, detailing its features, operation, safety guidelines, and warranty information.
Preview Prexiso PLT15 Laser & Tape Distance Measure User Manual | Accurate Measurements
User manual for the Prexiso PLT15 Laser & Tape Distance Measure. Learn about safety instructions, technical specifications, operation, care, and troubleshooting for this versatile measuring tool.
Preview Prexiso IC4 Laser Distance Meter User Manual and Safety Guide
Comprehensive guide to the Prexiso IC4 laser distance meter, covering setup, operations, technical specifications, care, warranty, and safety instructions. Learn how to measure, add, subtract distances, and understand device settings and laser safety.
Preview PREXISO P40T Laser Distance Measure User Manual
User manual for the PREXISO P40T Laser Distance Measure, covering setup, operation, functions, technical specifications, safety instructions, and warranty information.